Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 173 - 173
1 Mar 2006
Sirbu P Georgescu N Pencu D Ghionoiu G Cristea O Bruja R Asaftei R
Full Access

Aims. In order to limit the amount of both medial and lateral dissection, the MIPO technique was developed for extraarticular fractures of the femur. In this prospective study we have evaluated the outcome of 34 cases of supracondylar or subtrochanteric fractures of the femur treated by MIPO technique via exclusive proximal and distal incisions, using a DCS.

Material and methods. Between July 2000 and March 2003, 34 acute fractures (14 supracondylar and 20 subtrochanteric) in 33 patients were included in this study. The technique consisted of 5 major steps: 1. the insertion of the condylar screw using minimal incision; 2. the selection of DCS-plate by fluoroscopy; 3. the insertion of the DCS-plate beneath the vastus lateralis; 4. an additional minimal proximal or distal incision allows plate positioning and its slipping onto the condylar screw; 5. after the limb axis, length and rotation are confirmed by reliable clinical and radiological techniques, the plate was fixed to the shaft with 3 or 4 screws placed divergently.

Results. All fractures healed within a mean time of 14 weeks (range 8–24 weeks). 1 late implant failure (plate screw breakage) in an extremely cominutive fracture did not required repeat fixation. At follow-up, there were 5 varus-valgus deformities above 5°, 4 leg length discrepancies over 15 mm and 1 malrotation of 20°. According to the Neer score there were 22 excellent, 10 satisfactory and 2 unsatisfactory results.

Discussion. The key to MIPO is the use of 2-part and 2-plane alignment achieved by a DCS inserted in a sub-muscular fashion.

Conclusions. The MIPO technique with proximal and distal incisions minimizes surgical trauma and has the advantages of a faster rate of union, with no need for bone grafting. Care should be taken to ensure adequate axial and rotational alignment.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 244 - 244
1 Mar 2004
Sirbu P Georgescu N Stratan L Pencu D Ghionoiu G
Full Access

Aims: The purpose of this prospective study is to evaluate the outcome of 15 subtrochanteric femoral fractures treated by MIPO condylar screw (DCS) in 8 cases. Methods: The fractures were classified according to Seinsheimer (10 type IV and 5 type V). In order to limit the amount of both medial and lateral dissection, the plates were carefully inserted through isolated proximal incision only, behind the vastus lateralis; while the CBP was initially inserted with the blade pointing towards the surgeon, the MIPO technique was simplified by the technique, using a condylar blade plate (CBP) in 7 cases or a dynamic use of the two-part and two-plane alignment achieved by DCS. Results: All fractures healed, with a mean time of 12 weeks (range 8–16 weeks). There were no infections or implant failure. At follow-up, there were 3 varus deformities above 5°, 2 leg length discrepancies over 15 mm and 1 malrotation of 20°. The functional outcome (according to the Neer scale) was excellent in 10 cases and satisfactory in 5 cases. Conclusions: This demanding technique has the advantages of a faster rate of union, with no need for bone grafting. Care should be taken to ensure adequate axial and rotational alignment.