We report the natural course of Baker’s cysts following total knee arthroplasty (TKA) at short- and mid-term follow-up. In this prospective case series, 105 TKA patients were included. All patients who received surgery had a diagnosis of primary osteoarthritis and had preoperatively presented with a Baker’s cyst. Sonography and MRI were performed to evaluate the existence and the gross size of the cyst before TKA, and sonography was repeated at a mean follow-up time of 1.0 years (0.8 to 1.3; short-term) and 4.9 years (4.0 to 5.6; mid-term) after TKA. Symptoms potentially attributable to the Baker’s cyst were recorded at each assessment.Aims
Methods
We conducted a meta-analysis, including randomised
controlled trials (RCTs) and cohort studies, to examine the effect
of patient-specific instruments (PSI) on radiological outcomes after
total knee replacement (TKR) including: mechanical axis alignment
and malalignment of the femoral and tibial components in the coronal,
sagittal and axial planes, at a threshold of >
3º from neutral.
Relative risks (RR) for malalignment were determined for all studies
and for RCTs and cohort studies separately. Of 325 studies initially identified, 16 met the eligibility criteria,
including eight RCTs and eight cohort studies. There was no significant
difference in the likelihood of mechanical axis malalignment with
PSI We conclude that PSI does not improve the accuracy of alignment
of the components in TKR compared with conventional instrumentation. Cite this article:
Thromboembolic disease is a common complication of total hip replacement (THR). The administration of postoperative anticoagulants is therefore highly recommended. The purpose of this study was to compare rivaroxaban with fondaparinux with regards to their safety and effectiveness for the prevention of venous thromboembolic events (VTE) after THR. We conducted an independent prospective study comparing VTE prevention strategies in two successive series of patients (Groups A and B) undergoing elective unilateral THR. Group A (n=253) received fondaparinux daily 2.5 mg for 10 days, followed by tinzaparin 4500 IU daily for one month. Group B (n=229) received 10 mg rivaroxaban daily for 40 days without platelet monitoring. All surgeries were performed by a single surgeon under general anesthesia using an active blood transfusion-sparing plan. In the absence of contraindications, patients received intra-operative administration of tranexamic acid to reduce postoperative bleeding. Preoperative and postoperative hemoglobin levels were recorded at regular intervals. Bleeding events were documented. The bleeding index was calculated by adding the number of red blood cell units and the difference in the hemoglobin level (in g/dL) between the first morning after the day of surgery and the seventh postoperative day (POD 7). After 5 to 10 days, all patients underwent bilateral lower-extremity duplex ultrasonography to screen for deep venous thrombi. Any clinical symptoms of pulmonary embolism were evaluated with spiral computed tomography lung scans. Clinical evaluation to look for evidence of deep venous thrombi and pulmonary emboli was performed at eight weeks postoperatively.Background
Methods
Survival analysis is an important tool for assessing the outcome of total joint replacement. The Kaplan-Meier method is used to estimate the incidence of revision of a prosthesis over time, but does not account appropriately for competing events which preclude revision. In the presence of competing death, this method will lead to statistical bias and the curve will lose its interpretability. A valid comparison of survival results between studies using the method is impossible without accounting for different rates of competing events. An alternative and easily applicable approach, the cumulative incidence of competing risk, is proposed. Using three simulated data sets and realistic data from a cohort of 406 consecutive cementless total hip prostheses, followed up for a minimum of ten years, both approaches were compared and the magnitude of potential bias was highlighted. The Kaplan-Meier method overestimated the incidence of revision by almost 4% (60% relative difference) in the simulations and more than 1% (31.3% relative difference) in the realistic data set. The cumulative incidence of competing risk approach allows for appropriate accounting of competing risk and, as such, offers an improved ability to compare survival results across studies.