We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the rotator cuff. Patients were evaluated using the Constant score, subjective satisfaction levels and post-operative ultrasound scans. Of 115 consecutive patients who underwent arthroscopic repair of the rotator cuff at our institution, 102 were available for follow-up. The mean period of follow-up was for 35.8 months (24 to 73). The mean age of the patients was 57.3 years (23 to 78). There were 18 small (≤ 1 cm in diameter), 44 medium (1 cm to 3 cm in diameter), 34 large (3 cm to 5 cm in diameter) and six massive (>
5 cm in diameter) tears. There was a statistically significant increase in the size of the tear with increasing age (p = 0.0048). The mean pre-operative Constant score was 41.4 points (95% confidence interval, 37.9 to 44.9), which improved to 84.5 (95% confidence interval, 82.2 to 86.9). A significant inverse association (p = 0.0074), was observed between the size of the tear and the post-operative Constant score, with patients having smaller tears attaining higher Constant scores after repair. Post-operatively, 80 patients (78.4%) were able to resume their occupations and 84 (82.4%) returned to their pre-injury leisure activities. Only eight (7.8%) of 102 patients were not satisfied with the outcome. Recurrent tears were detected by ultrasound in 19 (18.6%) patients, and were generally smaller than the original ones. Patients with recurrent tears experienced a mean improvement of 31.6 points (95% confidence interval, 23.6 to 39.6) in their post-operative Constant scores. Those with intact repairs had significantly improved (p <
0.0001) Constant scores (mean improvement 46.3 points, 95% confidence interval, 41.9 to 50.6). Patient satisfaction was high in 94 cases (92%), irrespective of the outcome of the Constant score. Recurrent tears appear to be linked to age-related degeneration. Arthroscopic repair of the rotator cuff leads to high rates of satisfaction (92%) and good functional results, albeit with a recurrence rate of 18.6% (19 of 102).
The purpose of this study is to report the 1 to 5 year results of arthroscopic Rotator Cuff repairs. Between November 2001 to May 2003, 115 consecutive patients were operated (73 males and 42 females) with arthroscopic repair. 13 patients were lost to follow up, leaving 102 patients available for follow up. Patients were evaluated using the Constant score, satisfaction levels and ultrasound scan to evaluate cuff integrity. Failures were defined as dissatisfied patients and those who had had a re-operation. Re-tear rate was recorded. The mean follow up time was 23.8 months (range 12–61). Mean age was 57.3 years (range 23–78). 47% had a history of trauma. There were 107 patients (95.5%) with full thickness tears and 5 (4.5%) had partial thickness tears. Of the full thickness tears, 8 (7.6%) were massive in size, 36 (34%) large, 44 (41.5%) medium and 18(17%) small. Isolated Supraspinatus (SSP) tear was recorded in 83.5% and subscapularis tear in 7 %. A combination of SSP tear with infraspinatus and teres minor was found in 9.6%. 86% had Acromioplasty (ASD) with or without an AC joint excision arthroplasty. Two patients had Bankart repairs in addition at the time of cuff repair. The mean pre op Constant score was 40.9 points (95% CI 37.3 to 44.5), which had improved to 84.8 (CI 82.2 to 86.9) at last follow-up. 78% returned to same work and 82% returned to pre injury leisure activity. There were 20 re-tears (19.6%). eight of the 102 patients were not satisfied. Five of these patients had revision operation. Arthroscopic cuff repair shows high satisfaction rate (92%) and good functional results with 20% re-tear rate, while offering all the advantages of arthroscopic surgery.
Considerable controversy remains in the literature as to whether hemiarthroplasty or total shoulder arthroplasty (TSA) is the better treatment option for patients with shoulder arthritis. Several cohort studies have compared the outcomes of stemmed hemiarthroplasty with those of stemmed TSA and had inconsistent conclusions as to which procedure is best. However, these studies suggest that stemmed TSA provided better functional outcome. 340 CSRA cases were performed between 1987–2003, 218 Hemiarthroplasty – Humeral Surface Arthroplasty (HSA) and 122 TSA. There was very little difference in the functional outcome and pain in patients with and without a glenoid implant early, as well as, later after surgery. Mean post-operative Constant score for TSA was 85.0% (59.8 points) and for HSA patients 86.8% (62.3 points) with no statistically significant differences (t-test, p=0.4821). A highly significant difference between the overall proportions of revised cases was observed, with (21/122) 17.2% and (6/218) 2.8% of TSA and HSA cases revised, respectively (p<
0.0001). Further, HSA prostheses survive significantly longer than TSA prostheses. The difference between the survival curves was highly significant, both in the earlier post-operative period (Wilcoxon’s test, p=0.0053) as well as the later on (Log-rank test, p=0.0028). Long-term survival of total joint replacement is related to polyethylene wear debris, and therefore its use should be avoided if possible. The difference between our series and those with stemmed prostheses may be due to the fact that with surface replacement the normal anatomy for each patient can be mimicked better than with the stemmed prostheses and there is substantially less place for error as in stem positioning, head sizing or wrong version that may lead to glenoid erosion and less favourable result. Our current practice is and we suggest performing Copeland humeral surface replacement without insertion of glenoid prosthesis.
The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue. Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336 measurements overall. The mean laser Doppler flowmetry flux was significantly higher at the edges of the tear in torn cuffs (43.1, 95% confidence interval (CI) 37.8 to 48.4) compared with normal cuffs (32.8, 95% CI 27.4 to 38.1; p = 0.0089). It was significantly lower across all anatomical locations in cuffs with impingement (25.4, 95% CI 22.4 to 28.5) compared with normal cuffs (p = 0.0196), and significantly lower in cuffs with impingement compared with torn cuffs (p <
0.0001). Laser Doppler flowmetry analysis of the rotator cuff blood supply indicated a significant difference between the vascularity of the normal and the pathological rotator cuff. We were unable to demonstrate a functional hypoperfusion area or so-called ‘critical zone’ in the normal cuff. The measured flux decreases with advancing impingement, but there is a substantial increase at the edges of rotator cuff tears. This might reflect an attempt at repair.
Arthroscopic rotator cuff repair has evolved significantly in the last decade and has become a standard treatment. Satisfactory results of arthroscopic subacromial decompression (ASD) in the treatment of rotator cuff tears have also been reported (
We describe the results of Copeland surface replacement shoulder arthroplasty using the mark III prosthesis in patients over 80 years of age. End-stage arthritis of the shoulder is a source of significant pain and debilitating functional loss in the elderly. An arthroplasty offers good relief of pain and may allow the patient to maintain independence. The risk-benefit ratio of shoulder replacement may be felt to be too high in an elderly age group, but there is no published evidence to support this theory. We have assessed whether the procedure was as reliable and safe as previously seen in a younger cohort of patients. Between 1993 and 2003, 213 Copeland surface replacement arthroplasty procedures were performed in our unit, of which 29 (13.6%) were undertaken in patients over the age of 80. This group of patients was followed up for a mean of 4.5 years (2.1 to 9.3). Their mean age was 84.3 years (81 to 93), the mean operating time was 40 minutes (30 to 45) and the mean in-patient stay was five days (2 to 21). There were no peri-operative deaths or significant complications. The mean Constant score adjusted for age and gender, improved from 15.1% to 77%. Copeland surface replacement shoulder arthroplasty may be performed with minimal morbidity and rapid rehabilitation in the elderly.
Arthroscopic Rotator cuff repair is gaining popularity in recent years; however, the results of arthroscopic repairs are yet to be reported. Between November 2001 to May 2003, 115 consecutive patients were operated (73 males and 42 females) with arthroscopic repair. 13 patients were lost to follow up, leaving 102 patients available for follow up. The mean follow up time was 23.8 months (range 12–61). There were 107 patients (95.5%) with full thickness tears and 5 (4.5%) had partial thickness tears. Of the full thickness tears, 8 (7.6%) were massive in size, 36 (34%) large, 44 (41.5%) medium and 18(17%) small. Mean age was 57.3 years (range 23–78). 47% had a history of trauma. Mainly Supraspinatus (SSP) tear was recorded in 83.5% and isolated subscapularis tear in 7%. A combination of SSP tear with infraspinatus and teres minor minor (posterior tear) was found in 9.6%. 86% had Acromioplasty (ASD) with or without an AC joint excision arthroplasty. Two patients had Bankart repairs in addition at the time of cuff repair. Patients were evaluated using the Constant score, satisfaction levels and ultrasound scan to evaluate cuff integrity. Failures were defined as dissatisfied patients and those who had had a re-operation. Re-tear rate was recorded. The mean pre op Constant score was 40.9 points (95% CI 37.3 to 44.5), which had improved to 84.8 (CI 82.2 to 86.9) at last follow-up. 78% returned to same work and 82% returned to pre injury leisure activity. There were 20 ultrasound demonstrated re-tears (19.6%). However, the majority of patients with radiological re-tears had good function, pain relief and were satisfied. Eight of the 102 patients were not satisfied. Five of these patients had revision operation. Arthroscopic cuff repair shows high satisfaction rate (92%) and good functional results while offering all the advantages of arthroscopic surgery.
336 measurements were recorded. The observed mean LDFf was 32.8 (27.4–38.1; 95% CI) , 25.4 (22.4–28.5) and 43.1 (37.8–48.4; 95% CI) For Normal, Impingement and Tear cases, respectively (p<
0.0001, One-way ANOVA). The LDFf was lowest in the Impingement without tear grade (B2) with a statistically significant increase at the edges of a cuff tear.
The Constant-Murley score has gained wide acceptance for evaluation of shoulder function. The strength component of the Constant score accounts for 25 out of 100 points. It has been criticized for lack of consistency in defined measurement method. The aim of this study was to evaluate the effect of various variables on the strength component measurement of the Constant score.
The readings of the EZ force and the Isobex myometer were comparable.
No influence was found as well to the device being either fixed to an immobile platform or fixed to the floor by the examiner’s foot. These make these measurements easy to perform and reproducible using the newly designed digital force gauge (EZ force).
Diseased RC were sub grouped into mild (B1), moderate (B2) and severe (*B3 – cuff tear) impingement grades (Copeland – Levy Classification). The arthroscopy, grading, and probe placement were made by the senior authors. LDF flux (LDFf) was recorded over 30 seconds at each measurement point. The mean of these readings was then calculated (LDF flux – an arbitrary unit of measurement of the perfusion).
The LDFf was lowest in the moderate grade with a significant increase at the edges of a cuff tear.
The coraco-acromial ligament (CAL) is partially resected during a subacromial decompression. Clinical studies have reported the regeneration of a structure which appears to be a new CAL. Histological studies of regenerated CAL have demonstrated an abundance of relatively acellular collagen fibrils orientated in the line of a ligament and mechanical testing of the regenerated tissue has properties similar to those of normal CAL. However it is still not clear whether this structure represents scar tissue or truly reformed ligament. Defining the major collagen constituent of this regenerated tissue would allow the distinction between ligament and scar tissue. Therefore the aim of this study was to examine the level of expression of types I and III collagen in regenerated coraco-acromial ligaments (CAL) in humans. Samples of regenerated CAL were obtained during open surgery for repair of small rotator cuff tears at an average of 24 months (range 14 to 52) after arthroscopic subacromial decompression from 4 men and 3 women with an average age of 58 years (range 44 to 68). A standard protocol radio-active in-situ immunolocalisation technique was used to quantify the ratios of mRNA collagen I to collagen III in the samples. The results demonstrated that the average ratio of collagen I to collagen III was 6.5. This ratio is similar to the value for normal hip capsule (5–6:1) and human posterior cruciate ligament (8:1). We conclude that the reformed CALs are ligamentous structures, not scar tissue, and therefore represent truly regenerated ligaments.
Use of shoulder manipulation in the treatment of frozen shoulder (FS) remains controversial. One of the purported risks associated with the procedure is the development of a rotator cuff tear. However the incidence of iatrogenic rotator cuff tears has not been reported. The purpose of the study was to assess the effect of manipulation of the shoulder on the integrity of the rotator cuff. In a prospective study 20 consecutive patients (21 shoulders) with FS underwent manipulation of the shoulder under anaesthesia (MUA). The average duration of symptoms was 7.3 months (4–18 months). Patients were assessed pre and post manipulation using the Constant score. An ultrasound scan of the rotator cuff was performed before and at 3 weeks after manipulation. In all patients, pre and post manipulation ultrasound scans showed the rotator cuff to be intact. At 12 weeks after manipulation all patients indicated that they had none or only occasional pain. The mean improvement in motion was 83 degrees (range, 20 – 100°) for flexion, 95 degrees (range, 20 – 120°) for abduction, 58 degrees (range, 0 – 80°) for external rotation and 3 levels of internal rotation (range 3–5 levels). These gains in motion were all significant (p <
0.01). No fractures, dislocations or nerve palsies were observed. In conclusion manipulation under anaesthesia for treatment of frozen shoulder resulted in significant improvements in shoulder function and pain relief as early as 3 weeks after surgery and was not associated with rotator cuff tears. When performed carefully this procedure is safe and leads to early improvements in pain relief, range of movement and shoulder function.
Where a plica was present the impingement lesion seen on the cuff side was significantly greater than the lesion seen on the acromial side (p<
0.0001). This suggests that the impingement might be due to the plica itself.