It has become increasingly important to conduct studies assessing clinical outcomes, reoperation rates, and revision rates to better define the indications and efficacy of lumbar spinal procedures and its association with symptomatic adjacent segment degeneration (sASD). Adjacent segment degeneration (ASD) is defined as the radiographic change in the intervertebral discs adjacent to the surgically treated spinal level. SASD represents adjacent segment degeneration which causes pain or numbness due to post-operative spinal instability or nerve compression at the same level. The most common reason for early reoperation and late operation is sASD, therefore is in our best interest to understand the causes of ASD and make steps to limit the occurrence. A comprehensive literature search was performed selecting Randomized controlled trials (RCTs) and retrospective or prospective studies published up to December 2023. Meta-analysis was performed on 38 studies that met the inclusion criteria and included data of clinical outcomes of patients who had degenerative disc disease, disc herniation, radiculopathy, and spondylolisthesis and underwent lumbar fusion or motion-preservation device surgery; and reported on the prevalence of ASD, sASD, reoperation rate, visual analogue score (VAS), and Oswestry disability index (ODI) improvement.Background
Method
The primary aim of this study was to compare the clinical outcomes of osteoid osteoma (OO) between the group of patients with the presence of nidus on biopsy samples from radiofrequency ablation (RFA) with those without nidus. Secondly, we aimed to examine other factors that may affect the outcomes of OO reflecting our experience as a tertiary orthopaedic oncology centre. We retrospectively reviewed 88 consecutive patients diagnosed with OO treated with RFA between November 2005 and March 2015, consisting of 63 males (72%) and 25 females (28%). Sixty-six patients (75%) had nidus present in their biopsy samples. Patients’ mean age was 17.6 years (4-53). Median duration of follow-up was 12.5 months (6-20.8). Lesions were located in the appendicular skeleton in seventy-nine patients (90%) while nine patients (10%) had an OO in the axial skeleton. Outcomes assessed were based on patients’ pain alleviation (partial, complete, or no pain improvement) and the need for further interventions. Pain improvement in the patient group with nidus in histology sample was significantly better than the group without nidus (OR 7.4, CI 1.35-41.4, p=0.021). The patient group with nidus on biopsy demonstrated less likelihood of having a repeat procedure compared to the group without nidus (OR 0.092, CI 0.016-0.542, p=0.008). Our study showed significantly better outcomes in pain improvement in appendicular lesions compared to the axially located lesions (p = 0.005). Patients with spinal lesions tend to have relatively poor pain relief than those with appendicular or pelvic lesions (p=0.007). Patients with nidus on histology had better pain alleviation compared to patients without nidus. The histological presence of nidus significantly reduces the chance of repeat interventions. The pain alleviation of OO following RFA is better in patients with appendicular lesions than spinal or axially located lesions.
Current literature suggests that survival outcomes and local recurrence rates of primary soft-tissue sarcoma diagnosed in the very elderly age range, (over 90 years), are comparable with those in patients diagnosed under the age of 75 years. Our aim is to quantify these outcomes with a view to rationalizing management and follow-up for very elderly patients. Retrospective access to our prospectively maintained oncology database yielded a cohort of 48 patients across 23 years with a median follow-up of 12 months (0 to 78) and mean age at diagnosis of 92 years (90 to 99). Overall, 42 of 48 of 48 patients (87.5%) were managed surgically with either limb salvage or amputation.Aims
Methods
Proximal femoral endoprosthetic replacements (PFEPRs) are the most common reconstruction option for osseous defects following primary and metastatic tumour resection. This study aimed to compare the rate of implant failure between PFEPRs with monopolar and bipolar hemiarthroplasties and acetabular arthroplasties, and determine the optimum articulation for revision PFEPRs. This is a retrospective review of 233 patients who underwent PFEPR. The mean age was 54.7 years (SD 18.2), and 99 (42.5%) were male. There were 90 patients with primary bone tumours (38.6%), 122 with metastatic bone disease (52.4%), and 21 with haematological malignancy (9.0%). A total of 128 patients had monopolar (54.9%), 74 had bipolar hemiarthroplasty heads (31.8%), and 31 underwent acetabular arthroplasty (13.3%).Aims
Methods
While a centralized system for the care of patients with a sarcoma has been advocated for decades, regional variations in survival remain unclear. The aim of this study was to investigate regional variations in survival and the impact of national policies in patients with a soft-tissue sarcoma (STS) in the UK. The study included 1,775 patients with a STS who were referred to a tertiary sarcoma centre. The geographical variations in survival were evaluated according to the periods before and after the issue of guidance by the National Institute for Health and Care Excellence (NICE) in 2006 and the relevant evolution of regional management.Aims
Methods
Chondrosarcoma is the second most common primary sarcoma of bone: conventional chondrosarcoma accounts for 85% of all cases. Conventional chondrosarcoma may be central or peripheral. Most studies group central and peripheral chondrosarcomas together, although there is growing evidence that their clinical behaviour and prognosis differ. The aims of this study were to analyze any differences in characteristics between central and peripheral chondrosarcomas and to investigate the incidence and role of different syndromes. Data from two international tertiary referral sarcoma centres between January 1995 and December 2018 were retrospectively reviewed. The study population consisted of 714 patients with surgically treated conventional chondrosarcoma of the pelvis and limbs.Aims
Methods
Urgent referral to a specialist centre for patients with a soft-tissue sarcoma (STS) has been recommended by the National Institute for Health and Care Excellence (NICE) in the UK since 2006. However, the impact of this recommendation on the prognosis for these patients remains unclear. We aimed to determine the impact of the NICE guidelines on the disease-specific survival (DSS) of patients with an STS. A total of 2,427 patients with an STS referred to a supraregional centre in the ten-year periods before (n = 1,386) and after (n = 1,041) the issue of the NICE guidelines were evaluated.Aims
Methods
Aims Although chondrosarcomas (CSs) display true malignant features, including local recurrence (LR) and metastases, their behaviour in the hands and feet is thought to differ from that in other parts of the axial and appendicular skeleton by having a lower metastatic potential. The purpose of this study was to investigate the disease-specific and surgical factors that affect the local and systemic prognosis of CS of the hands and feet. A multicentre retrospective study was carried out at two tertiary sarcoma centres. A database search identified all patients with a CS treated between January 1995 and January 2018. There were 810 CSs of which 76 (9.4%) were located in the fingers, toes, metacarpals, and metatarsal bones. The median age of the study population was 55 years (36 to 68) with a median follow-up of 52 months (22 to 87) months. Overall, 70% of the tumours were in the hand (n = 54) and 30% in the foot (n = 22). Predictors for LR were margin (p = 0.011), anatomical location (p = 0.017), and method of surgical management (p = 0.003). Anatomical location (p = 0.026), histological grade between 1 and 3 (p = 0.004) or 2 and 3 (p = 0.016), and surgical management (p = 0.001) were significant factors for LR-free survival. Disease-specific survival was affected by histological grade (p < 0.001), but not by LR (p = 0.397).Methods
Results
Malignancy and surgery are risk factors for venous thromboembolism (VTE). We undertook a systematic review of the literature concerning the prophylactic management of VTE in orthopaedic oncology patients. MEDLINE (PubMed), EMBASE (Ovid), Cochrane, and CINAHL databases were searched focusing on VTE, deep vein thrombosis (DVT), pulmonary embolism (PE), bleeding, or wound complication rates.Aims
Methods
The existing clinical guidelines do not describe a clear indication for adjuvant radiotherapy (RT) in the treatment of superficial soft tissue sarcomas (STSs). We aimed to determine the efficacy of adjuvant RT for superficial STSs. We retrospectively studied 304 patients with superficial STS of the limbs and trunk who underwent surgical resection at a tertiary sarcoma centre. The efficacy of RT was investigated according to the tumour size and grade: group 1, ≤ 5 cm, low grade; group 2, ≤ 5cm, high grade; group 3, > 5 cm, low grade; group 4, > 5 cm, high grade.Aims
Methods
The aim of this study was to report the results of custom-made endoprostheses with extracortical plates plus or minus a short, intramedullary stem aimed at preserving the physis after resection of bone sarcomas in children. Between 2007 and 2017, 18 children aged less than 16 years old who underwent resection of bone sarcomas, leaving ≤ 5 cm of bone from the physis, and reconstruction with a custom-made endoprosthesis were reviewed. Median follow-up was 67 months (interquartile range 45 to 91). The tumours were located in the femur in 11 patients, proximal humerus in six, and proximal tibia in one.Aims
Patients and Methods
Investigate the incorporation of an antibiotic in bone cement using liposomes (a drug delivery system) with the potential to promote osseointegration at the bone cement interface whilst maintaining antibiotic elution, anti-microbiological efficacy and cement mechanical properties. Prosthetic joint infection and aseptic loosening are associated with significant morbidity. Antibiotic loaded bone cement is commonly used and successfully reduces infection rates; however, there is increasing resistance to the commonly used gentamicin. Previous studies have shown gentamicin incorporated into bone cement using liposomes can maintain the cement's mechanical properties and improve antibiotic elution. The phospholipid phosphatidyl-l-serine has been postulated to encourage surface osteoblast attachment and in a liposome could improve osseointegration, thereby reducing aseptic loosening. Preliminary clinical isolate testing showed excellent antimicrobial action with amoxicillin therefore the study aims were to test amoxicillin incorporated into bone cement using liposomes containing phosphatidyl-l-serine in terms of antibiotic elution, microbiological profile and mechanical properties. Amoxicillin was encapsulated within 100nm liposomes containing phosphatidyl-L-serine and added to PMMA bone cement (Palacos R (Heraeus Medical, Newbury, UK)). Mechanical testing was performed according to Acrylic Cement standards (ISO BS 5833:2002). Elution testing was carried out along with microbiological testing utilising clinical isolates.Objectives
Methods
Preserving growth following limb-salvage surgery of the upper
limb in children remains a challenge. Vascularized autografts may
provide rapid biological incorporation with the potential for growth
and longevity. In this study, we aimed to describe the outcomes
following proximal humeral reconstruction with a vascularized fibular
epiphyseal transfer in children with a primary sarcoma of bone.
We also aimed to quantify the hypertrophy of the graft and the annual
growth, and to determine the functional outcomes of the neoglenofibular
joint. We retrospectively analyzed 11 patients who underwent this procedure
for a primary bone tumour of the proximal humerus between 2004 and
2015. Six had Ewing’s sarcoma and five had osteosarcoma. Their mean
age at the time of surgery was five years (two to eight). The mean
follow-up was 5.2 years (1 to 12.2).Aims
Patients and Methods
Following the resection of an extensive amount of bone in the
treatment of a tumour, the residual segment may be insufficient
to accept a standard length intramedullary cemented stem. Short-stemmed
endoprostheses conceivably have an increased risk of aseptic loosening.
Extra-cortical plates have been added to minimise this risk by supplementing
fixation. The aim of this study was to investigate the survivorship
of short-stemmed endoprostheses and extra-cortical plates. The study involved 37 patients who underwent limb salvage surgery
for a primary neoplasm of bone between 1998 and 2013. Endoprosthetic
replacement involved the proximal humerus in nine, the proximal
femur in nine, the distal femur in 13 and the proximal tibia in
six patients. There were 12 primary (32%) and 25 revision procedures (68%).
Implant survivorship was compared with matched controls. The amount
of bone that was resected was >
70% of its length and statistically
greater than the standard control group at each anatomical site.Aims
Patients and Methods
Devices are frequently used to gain sufficient purchase in a bone so that the bone itself can be manipulated to move or rupture soft tissue attachments. During hip surgery, several different extraction corkscrews are available to remove the femoral head, each with a different screw design with no evidence to suggest which is most effective. Additionally during the use of corkscrew devices, often due to the low bone density, stripping of the screw threads out of the femoral head can occur prior to its extraction, thus requiring reinsertion. The aims of this project were to measure the primary pullout and reinsertional forces of five commercially available corkscrews. Polyurethane bone models covering a spectrum of osteoporotic to normal bone densities (0.08 gcm-3, 0.16 gcm-3 and 0.32 gcm-3) were used in axial tensile testing at two insertional depths to assess the maximum pullout force of these corkscrews (Zimmer, Stryker, Medacta, JRI, Depuy).Background
Methods
Compare clinical outcomes following staged revision arthroplasty for periprosthetic joint infection (PJI) secondary to either multidrug resistant (MDR) bacteria or non-MDR (NMDR) bacteria. Retrospective analysis of a prospectively collected bone infection database. Adult patients diagnosed and treated for hip or knee PJI, between January 2011 and December 2014, with minimum one-year follow-up, were included in the study. Patients were divided into two groups: MDR group (defined as resistance to 3 or more classes) and N-MDR group (defined as acquired resistance to two classes of antibiotic or less). The Charlson Comorbidity Index was used to stratify patients into low, medium and high risk. The diagnosis of PJI, and any recurrence following treatment, was made in accordance with the Musculoskeletal Infection Society criteria. Failure was defined as recurrence of infection necessitating implant removal, excision arthroplasty, arthrodesis or amputation.Aim
Method
25–40% of unicompartmental knee replacement (UKR) revisions are performed for unexplained pain possibly secondary to elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on cancellous bone strain in a finite element model (FEM) of a cemented fixed bearing medial UKR, validated using previously published acoustic emission data (AE). FEMs of composite tibiae implanted with an all-polyethylene tibial component (AP) and a metal backed one (MB) were created. Polyethylene of thickness 6–10mm in 2mm increments was loaded to a medial load of 2500N. The volume of cancellous bone exposed to <−3000 (pathological overloading) and <−7000 (failure limit) minimum principal (compressive) microstrain (µ∊) and >3000 and >7000 maximum principal (tensile) microstrain was measured. Linear regression analysis showed good correlation between measured AE hits and volume of cancellous bone elements with compressive strain <−3000µ∊: correlation coefficients (R= 0.947, R2 = 0.847), standard error of the estimate (12.6 AE hits) and percentage error (12.5%) (p<0.001). AP implants displayed greater cancellous bone strains than MB implants for all strain variables at all loads. Patterns of strain differed between implants: MB concentrations at the lateral edge; AP concentrations at the keel, peg and at the region of load application. AP implants had 2.2 (10mm) to 3.2 (6mm) times the volume of cancellous bone compressively strained <−7000µ∊ than the MB implants. Altering MB polyethylene insert thickness had no effect. We advocate using caution with all-polyethylene UKR implants especially in large or active patients where loads are higher.
Bone tumours of the foot are rare, representing 3–6% of all bone tumours. Of these 15–25% are thought to be malignant. Obtaining clear surgical margins remains an important factor in improving outcome from tumours. However, the anatomical complexity of the foot can lead to an inadequate resection, particularly if the operating surgeon is attempting to preserve function. The aim of this paper is to identify the clinical course of patients suffering from malignant bone tumours of the foot. A prospective tumour registry over a 30 yr period was used to identify patients with a malignant bone tumour of the foot. Patient demographics along with the site of primary malignancy, region of the foot involved and clinical management were recorded.Introduction
Method
The management of spinal deformity in children
with univentricular cardiac pathology poses significant challenges to
the surgical and anaesthetic teams. To date, only posterior instrumented
fusion techniques have been used in these children and these are
associated with a high rate of complications. We reviewed our experience
of both growing rod instrumentation and posterior instrumented fusion
in children with a univentricular circulation. Six children underwent spinal corrective surgery, two with cavopulmonary
shunts and four following completion of a Fontan procedure. Three
underwent growing rod instrumentation, two had a posterior fusion
and one had spinal growth arrest. There were no complications following
surgery, and the children undergoing growing rod instrumentation
were successfully lengthened. We noted a trend for greater blood
loss and haemodynamic instability in those whose surgery was undertaken
following completion of a Fontan procedure. At a median follow-up
of 87.6 months (interquartile range (IQR) 62.9 to 96.5) the median
correction of deformity was 24.2% (64.5° (IQR 46° to 80°) We believe that early surgical intervention with growing rod
instrumentation systems allows staged correction of the spinal deformity
and reduces the haemodynamic insult to these physiologically compromised
children. Due to the haemodynamic changes that occur with the completed
Fontan circulation, the initial scoliosis surgery should ideally
be undertaken when in the cavopulmonary shunt stage. Cite this article:
Joint registries report that 25–40% of UKR revisions are performed for pain. Proximal tibial strain and microdamage are possible causes of this “unexplained” pain. The aim of this study was to examine the effect of UKR implant design and material on proximal tibial cortical strain and cancellous microdamage. Composite Sawbone tibias were implanted with cemented UKR components: 5 fixed bearing all-polyethylene (FB-AP), 5 fixed bearing metal backed (FB-MB), and 5 mobile bearing metal backed implants (MB-MB). Five intact tibias were used as controls. Tibias were loaded in 500N increments to 2500N. Cortical surface strain was measured using digital image correlation (DIC). Cancellous microdamage was measured using acoustic emission (AE), a technique which detects elastic waves produced by the rapid release of energy during microdamage events. DIC showed significant differences in anteromedial cortical strain between implants at 1500N and 2500N in the proximal 10mm only (p<0.001) with strain shielding in metal backed implants. AE showed significant differences in cancellous microdamage (AE hits), between implants at all loads (p=0.001). FB-AP implants displayed significantly more hits at all loads than both controls and metal backed implants (p<0.001). FB-AP implants also differed significantly by displaying AE hits on unloading (p=0.01), reflecting a lack of implant stiffness. Compared to controls, the FB-AP implant displayed 15x the total AE hits, the FB-MB 6x and the MB-MB 2.7x. All-polyethylene medial UKR implants are associated with greater cancellous bone microdamage than metal backed implants even at low loads.