We aim to report the clinical and radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong HAC coated femoral and acetabular components. We reviewed 586 consecutive cementless primary THA in 542 patients, with a minimum 12-year follow-up to 18 years, performed at one institution between 1986 and 1994. Twenty eight (32 THA) were lost to follow-up. Clinical outcome was measured using Harris, Charnley and Oxford scores. Quality of life using EuroQol EQ-5D. Radiographs were systematically analysed.Introduction
Methods
The HA coated implants remained asymptomatic. Three uncoated components required revision for migration. No evidence of accelerated UHMWPE wear was seen on retrievals or radiographs. Histological analysis of the retrieved HA coated specimens showed excellent bony fixation, uncoated cups showed predominantly fibrous tissue.
We aim to report the clinical, radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong Hydroxyapatite ceramic coated acetabular components. We reviewed 412 consecutive primary THA using fully coated acetabular shell in 392 patients, with minimum 12-year follow-up to 18 years, performed at two institutions. Twenty (22 THA) were lost prior to 12-year follow-up, leaving 372 patients (390 THA) available for study. Fully HAC coated stems were used in all patients. Clinical outcome was measured using Harris, Charnley Oxford, EuroQol EQ-5D scores. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Polythene wear was digitally measured. Mean age was 74.4 yrs. Dislocation occurred in 10 patients (3 recurrent). Revision operations were performed in nine patients (1.9%). Four acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (3), periprosthetic fractures (1), cup malposition (1), revision of worn liner (3). The mean Harris and Oxford scores were 87 (78–97) and 19.1 (12–33) respectively. The Charnley score was 5.6 (5–6) for pain, 5.2 (4–6) for movement and 5.3 (4–6) for mobility. Migration of acetabular component was seen in 4 hips. Acetabular radiolucencies were present in 54 hips (9.7%). The mean linear polythene wear was 0.06mm/year. Mean inclination was 48.4 deg(38–65). Mean EQ-5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, the probability of survival at 12 years was 96.1%. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 94.2%. The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long term period
We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips). The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris.
Computer navigation assistance in total knee arthroplasty (TKA) results in more consistently accurate postoperative alignment of the knee prostheses. However the medium and long term clinical outcomes of computer-navigated TKA are not widely published. Our aim was to compare patient perceived outcomes between computer navigation assisted and conventional TKA using the Oxford knee score (OKS). We retrospectively collected data on 441 primary TKA carried out by a single surgeon in a dedicated arthroplasty centre over a period of four years. These were divided according to use of computer navigation (group A) or standard instrumentation (group B). There were no statistical differences in baseline Oxford knee score (OKS) and demographic data between the groups. 238 of these had at least a one-year follow-up with 109 in group A and 129 in group B. Two year follow-up data was available for 105 knees with 48 in group A and 57 in group B and a three year follow-up for 45 with 21 and 24 in groups A and B respectively. 12 patients had completed four year follow-up with seven and five knees in groups A and B respectively. The mean OKS at 1-year follow up was 24.98 (range 12– 54, SD 9.34) for group A and 26.54 (range 12– 51, SD 10.18) for group B (p = 0.25). Similarly at 2-years the mean OKS was 25.40 (range 12– 53, SD 9.51) for group A and 25.56 (range 12– 46, SD 9.67) for group B (p = 0.94). The results were similar for three and four-year follow ups with p values not significant. This study thus revealed that computer assisted TKA does not appear to result in better patient satisfaction when compared to standard instrumentation at midterm follow up. It is known from long term analysis of conventional TKA that mal-aligned implants have significantly higher failure rates beyond eight to ten years. As use of computer navigation assistance results in a less number of mal-aligned knee prostheses, we believe that these knees will have improved survivorship. The differences in OKS between the two groups should therefore be evident after eight to ten years.