Acetabular reconstruction with impaction bone grafting and a cemented polyethylene aims to reconstitute the bone stock in hip revision. This is an effective but expensive, resource intensive and time consuming technique. Most surgeons remove the articular cartilage from the femoral head allograft. The aim of this study is to reproduce the results using the whole femoral head with the articular cartilage for acetabular impaction grafting. 38 acetabular revisions using impacted morselised bone graft retaining the articular cartilage and a cemented cup were studied retrospectively. The operations were performed by the senior author in Wrightington Hospital, UK with a posterior hip approach. The mean follow up was 4.1 years (range, 1–10 years). Clinical and radiological assessment was made using the Oxford hip score, Hodgkinson's criteria (1988) for socket loosening and the Gie classification (1993) for evaluation of allograft incorporation. Thirty-six (94.7%) sockets were considered radiologically stable (type 0, 1, 2 demarcations) and two (5.3%) sockets were radiologically loose (type 3 demarcations) but there was no socket migration. Twenty-one (55.3%) cases showed good trabecular remodeling (grade 3). Fourteen (36.8 %) cases showed trabecular remodeling (grade 2). Only three (7.9%) cases showed poor allograft incorporation (grade 1). Mean pre-operative hip score was 41 and post-operative hip score was 21. There was one (2.6%) wound infection treated with oral antibiotics and one (2.6%) periprosthetic femoral fracture treated with cables. Furthermore, there was one (2.6%) case of pulmonary embolism and three (7.89%) cases of asymptomatic heterotopic ossification. One year mortality rate was 2.6% (one case) from heart failure but not associated with the surgery. There have been no socket re-revisions (100% survival) at an average of 4 years. At a mean follow up of 4 years, results with the aforementioned technique are comparable to other major studies. Compared to the 40% of minimal loss in obtaining pure cancellous graft less than 10% of initial graft mass is lost without removing the articular cartilage. Particularly when the supply of allograft and operative time are limited retaining the articular cartilage of the femoral head is a safe and effective alternative to be considered.
Post-operative swelling and wound ooze following primary Total Knee Replacement (TKR) can lead to complications such as wound infection, and delays in achieving adequate range of motion. The aim of the study is to examine the effectiveness of using an additional layer of a self-adherent elastic wrap (CobanTM) in reducing post-operative swelling and wound ooze after Primary TKR. Seventeen pairs of patients who had had a primary TKR were studied in a prospective, age and gender-matched cohort study. Half of the patients had wool and crepe dressing (Group A) and the other half with an additional layer of CobanTM dressing (Group B), applied to the wound. Limb circumference was measured at three levels (below knee, knee and above knee) preoperatively and 3 consecutive days post-operatively. The area of wound ooze was measured using AutoCAD software. Group B showed a significant reduction difference in the mean of post-operative limb circumference at above knee level (3.2 vs 4.9 cm. Within the relative small size of this study, there appeared a significant reduction in post-operative limb swelling and wound ooze when using CobanTM in TKR. It is promising preliminary results, however the study groups must be extended.