Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 5 - 5
1 May 2017
Aguilera-Correa J Doardrio A Conde A Arenas M de Damborenea J Pérez-Jorge C Vallet-Regí M Esteban J
Full Access

Introduction

Prosthetic joint infections (PJI) occur infrequently, but due to its increased clinical use represent the most devastating complication with high morbidity and substantial cost. Staphylococcus aureus and coagulase-negative staphylococci are the most common infecting agents associated with PJI. A possible therapeutic approach could be the local antibiotic by fluoride-TiO2 nanostructured anodic layers in order to prevent surface colonisation during the early moments after surgery. Here we describe the first results of this model using two common antibiotics.

Methods

Fluoride-TiO2 nanostructured anodic layers on Ti6Al4V alloy were produced as described previously by Arenas et al (2013). Discs shaped pieces of Ti6Al4V alloy were loaded with a solution of 150 mg antibiotic (vancomycin or gentamicin)/20 ml sterile distilled water. Samples were immersed in this solution during 24 hours at room temperature with agitation, and then were dried during 48 hours at 20°C. Antibiotic release was studied by introducing both discs in sterile PBS and samples were taken at different times. Samples were then frozen at −80°C until HPLC measurements and biological activity tests using Bacillus subtilis ATCC 6051 (vancomycin) and Escherichia coli ATCC 25922 (gentamicin) were performed.