Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 63 - 63
1 Dec 2016
Chen A Kazarian G Kim T Hollern D Deirmengian C
Full Access

Aim

Hospital systems have recently instituted early systemic sepsis recognition systems, where vital signs and laboratory findings are monitored and automatically alert providers to potential sepsis. Although there are very few reports evaluating the use of sepsis alert systems outside of the emergency room or intensive care unit, many hospital systems have made the decision to apply the sepsis alarm protocols to all inpatients. The purpose of this study was to evaluate if an alarm system using systemic inflammatory response syndrome (SIRS) criteria is a valuable tool to predict systemic sepsis in the immediate postoperative period (POD#0–4) after total joint arthroplasty (TJA).

Method

10,791 primary and revision TJA patients at one institution, from 2010–2014, were retrospectively reviewed for positive SIRS criteria on each hospital day from the date of surgery to postoperative day four (POD#4). SIRS criteria included temperature > 38°C or < 36°C, heart rate > 90 beats per minute, respiratory rate > 20 breaths per minute, and white blood cell (WBC) > 12,000/mm3 or < 4,000/mm3. Additionally, hospital coding data was cross-referenced to identify patients who were diagnosed with systemic sepsis within 10 days after having a TJA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 45 - 45
1 Dec 2013
Deirmengian C Kardos K Kilmartin P Cameron A Chung D Booth R Parvizi J
Full Access

INTRODUCTION:

The diagnosis of periprosthetic joint infection (PJI) remains a serious challenge. Based on previous work, we believe that biomarkers will become the mainstay of diagnosing PJI in the future. We report on completion of our 8 year comprehensive biomarker program, evaluating the diagnostic profile of the 15 most promising synovial fluid biomarkers.

METHODS:

Synovial fluid was prospectively collected from 99 patients being evaluated for infection in the setting of revision hip or knee arthroplasty. All synovial fluid samples were tested by immunoassay for 15 putative biomarkers that were developed and optimized specifically for use in synovial fluid. Sensitivity, specificity and receiver operating Characteristic (ROC) curve analysis were performed for all biomarkers.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 274 - 274
1 Dec 2013
Cooper J Urban R Deirmengian C Paprosky W Jacobs JJ
Full Access

Introduction

Taper corrosion at modular junctions can cause a spectrum of adverse local tissue reactions (ALTR) in the periprosthetic soft tissues in patients who have undergone total hip arthroplasty (THA). Because these reactions are usually painful, taper corrosion has become part of the differential diagnosis of hip pain following THA. However these destructive lesions may not always cause pain, and can occasionally result in other atypical presentations. The purpose of this study is to describe a cohort of patients presenting with late and recurrent instability following THA due to underlying ALTR and taper corrosion.

Methods

This is a multicenter retrospective case series of fourteen patients presenting with late instability secondary to ALTR and corrosion at the modular head-neck taper. The cohort included nine women and five men with a mean age of 66.8 years (range, 49 to 74). All patients had a metal (CoCr)-on-polyethylene bearing surface, but had a range of CoCr and Ti-alloy stem designs from three different manufacturers. Seven patients had 28 mm heads, while the rest had 32–40 mm heads. Patients experienced a mean of 3.4 dislocations (range, 2 to 6) at an average of 5.2 years (range, 0.4 to 17.0) following their index surgery. Although most reported some degree of discomfort around the hip, instability was the primary presenting symptom in all fourteen patients, and four were otherwise completely asymptomatic. Serum metal levels demonstrated a greater elevation of cobalt (mean 3.13 ng/mL) than chromium (mean 2.33 ng/mL). Preoperative infection workup including serum inflammatory markers and a hip aspiration documented the absence of sepsis.