Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 79 - 79
19 Aug 2024
Hormi-Menard M Wegrzyn J Girard J Faure P Duhamel A Erivan R Migaud H
Full Access

The results of total hip arthroplasty (THA) revisions to correct leg length discrepancy (LLD) are not clear, with only two former limited series (< 25 patients). Therefore, we conducted a retrospective study of THA revisions for LLD to determine: 1) the change in LLD, 2) the function outcomes and whether obtaining equal leg lengths influenced function, 3) the complication and survival rates.

This multicenter study included 57 patients: 42 THA revisions for limb shortening and 15 revisions for limb lengthening. LLD was measured on conventional radiographs and EOS. The Oxford-12 and FJS outcome scores were collected and the number of patients achieving the Oxford-12 MCID.

The revisions were carried out a mean of 2.8 years after the index THA. The median LLD decreased from 7.5 mm (IQR: [5;12]) to 1 mm (IQR: [0.5;2.5]) at follow-up (p=0.0002). Overall, 55 of 57 patients (96%) had < 5 mm LLD at follow-up and 12 patients (21%) had equal leg lengths. The complication rate was 25%: 12 mechanical complications (8 periprosthetic femoral fractures, 2 stem loosening and 1 cup loosening, 1 dislocation) and 1 periprosthetic infection. The patient satisfaction was high with a median FJS of 79.2/100 and 77% of patients reached the Oxford-12 MCID. Lengthening procedures had significantly worst function than shortening (38% vs 91% of patients achieving the Oxford-12 MCID (p=0.0004)). Survivorship was 85% (95% CI: 77.9 – 92.5) at 2 years and 77% (95% CI: 66.3 – 87.1) at 4.6 years when using re-revision for any reason as the endpoint.

When LLD after THA does not respond to conservative management, revision THA should be considered. Although revision THA for LLD improved medium-term functional outcomes with a high patient satisfaction rate, especially for shortening procedures, the complication rate was high, particularly related to periprosthetic femoral fracture.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 267 - 267
1 Jul 2008
MIGAUD H PINOIT Y HERENT S SOENEN M BACHOUR F MAY O LAFFARGUE P DUHAMEL A DEVOS P
Full Access

Purpose of the study: In order to evaluate the influence of prosthesis design and resurfacing on the outcome of total hip arthroplasty (THA) implanted without cement, we reviewed the orthopedic literature from 1980 to 2004.

Material and methods: The PubMed database was screened from 1980 to 2004 for publications reporting cementless THA with a follow-up analysis. The same criteria were used to screen three registries. In all, the publications retained had studied 50,162 cementless THA (mean patient age 48.9 years, mean follow-up 6.5 years) where were studied according to rate of revision, presence of osteolysis, and presence of operative fractures. Eleven families of components grouped together the majority of prostheses: five acetabular families [screw fixation without resurfacing (n=2997), screw fixation with hydroxyapatite (HA) resurfacing (n=3618), screw fixation with corindon resurfacing (2360), press-fit mac-roporous (15691), press-fit HA (6094)]; and six families of femoral pivots [straight macroprous (n=7502), straight HA (n=3255), straight corindon (n=6136), anatomic HA (n=3468), anatomic macroporous (n=1215), anatomic corindon (n=1041)].

Results: The rates of revision and of osteolysis were higher for screw fixed cups without resurfacing. For screw fixed or press-fit cups, HA resurfacing did not reduce the rate of revision compared with corindon coated or macroporous implants. For anatomic pivots, adjunction of HA resurfacing reduced the rate of revision but at the shortest follow-up and without reducing the rate of osteolysis. Corindon-coated pivots gave comparable results for straight or anatomic implants. Conversely, HA-coated pivots gave better results with an anatomic design. The shape of the pivot had les effect than resurfacing on osteolysis and revision, but had a greater influence on operative fractures (2.9% for straight implants versus 4.6% for anatomic versions).

Conclusion: In all:

uncoated implants should be abandoned;

HA resurfacing does not reduce the rate of revision and can be associated with a higher rage of osteolysis;

there is no advantage between screw fixed or press-fit cups as long as the cup has a quality resurfacing;

there is no real difference between straight and anatomic pivots except that intraoperative fracture can be lower for the straight implants.