Biomaterial-associated infections (BAI) present a formidable clinical challenge. Bioactive glasses (BG) have proven highly successful in diverse clinical applications, especially in dentistry and orthopaedics. In this study, we aimed to determine the effect of three commonly used BG composition and particle sizes on cell and bacterial attachment and growth. Our focus is on understanding the changes in pH and osmotic pressure in the surrounding environment during glass degradation. First, three different melt-derived glasses were characterized by analyzing particle size and glass network structure using Raman and NMR. The different glasses were then tested in vitro by seeding 4x 104 cells/well (SaOS Cell line) in a 48 well plate. After a pre-incubation period of 72 hours, the different BGs and particle sizes were added to the cells and the pH value, ion release and live/dead staining was measured every hour. The effect of BG against bacteria (Aim
Method
Lower limb fractures are common in low- and middle-income countries (LMICs) and represent a significant burden to the existing orthopaedic surgical infrastructure. In high income country (HIC) settings, internal fixation is the standard of care due to its superior outcomes. In LMICs, external fixation is often the surgical treatment of choice due to limited supplies, cost considerations, and its perceived lower complication rate. The aim of this systematic review protocol is identifying differences in rates of infection, nonunion, and malunion of extra-articular femoral and tibial shaft fractures in LMICs treated with either internal or external fixation. This systematic review protocol describes a broad search of multiple databases to identify eligible papers. Studies must be published after 2000, include at least five patients, patients must be aged > 16 years or treated as skeletally mature, and the paper must describe a fracture of interest and at least one of our primary outcomes of interest. We did not place restrictions on language or journal. All abstracts and full texts will be screened and extracted by two independent reviewers. Risk of bias and quality of evidence will be analyzed using standardized appraisal tools. A random-effects meta-analysis followed by a subgroup analysis will be performed, given the anticipated heterogeneity among studies, if sufficient data are available.Aims
Methods
We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients. A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up.Aims
Methods
Flexor sheath infections require prompt diagnosis, and management with intravenous antibiotics and/or surgical washout followed by physiotherapy. Complication rates as high as 38% have been reported. A retrospective review was carried out of all patients between January 2014 and May 2021 attending with a suspected or confirmed diagnosis of flexor sheath infection. Age, gender, co-morbidities, cause of infection, management, and subsequent complications recorded.Introduction
Methods
There are limited long-term studies reporting on outcomes of the Zimmer Modular Revision (ZMR) stem, and concerns remain regarding failure. Our primary aim was to determine long-term survival free from all-cause revision and stem-related failure for this modular revision stem in revision total hip arthroplasty (THA). Secondary aims included evaluating radiological and functional outcomes. We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR system from January 2000 to December 2007. We included 106 patients (108 hips) with a mean follow-up of 14.5 years (2.3 to 22.3). Mean patient age was 69.2 years (37.0 to 89.4), and 51.9% were female (n = 55). Indications for index revision included aseptic loosening (73.1%), infection (16.7%), fracture (9.3%), and stem fracture (0.9%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. At most recent follow-up, Oxford Hip Scores (OHS) were collected, and radiological stem stability was determined using the Engh classification.Aims
Methods
Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.Aims
Methods
The purpose of this study was to determine long-term survival free from all-cause revision and stem-related failure, as well as radiographic and functional outcomes of the ZMR stem in revision THA. We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR Revision Hip system from the year 2000 to 2007 (minimum two-year follow-up). Of the 112 ZMR hips (110 patients) identified, a total of 106 hips (104 patients) met inclusion criteria. The mean study follow-up 13.9 years (range 2–22). Indications for index ZMR revision included aseptic loosening (72.1%), periprosthetic joint infection (17.3%), periprosthetic fracture (9.6%), and stem fracture (1.0%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. Validated patient reported outcomes were collected and available radiographs were reviewed to determine implant stability. A total of 17 hips (16.0%) underwent a re-revision of any component. The indications for re-revision were stem failure (35.3%), infection (29.4%), instability (29.4%), and aseptic loosening of the acetabular component (5.9%). The five- and 15-year all-cause survivorship was 89.5% (95% CI 86.5–92.5) and 83.0% (95% CI 79.2–86.8), respectively. There were six re-revisions for stem failure (5.7%); five for stem fracture and one for aseptic loosening. The average time to stem failure was 4.6 years (range 1.3–8.2). The five- and 15-year survivorship free from stem-related failure was 97.2% (95% CI 95.6–98.8) and 93.9% (95% CI 91.5–96.3), respectively. At final follow-up the mean Oxford hip score was 36.9 and all surviving ZMR stems were well fixed on radiographs. Femoral revision with the ZMR stem offers satisfactory long-term survivorship and promising clinical outcomes. Although uncommon, stem fracture was the most common reason for stem-related failure.
The aim of this study was to describe services available to patients with periprosthetic femoral fracture (PPFF) in England and Wales, with focus on variation between centres and areas for care improvement. This work used data freely available from the National Hip Fracture Database (NHFD) facilities survey in 2021, which asked 21 questions about the care of patients with PPFFs, and nine relating to clinical decision-making around a hypothetical case.Aims
Methods
Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings. A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. ‘Controls’ were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size.Aims
Methods
A hip fracture represents the extreme end of osteoporosis, placing a significant burden on secondary care, society, and the individual patient. The National Hip Fracture Database (NHFD) reports each hospital's attainment of the BPT with other measures, along with reporting outcomes. There is clearly wide variability in provision of orthogerriatrician (OG) services across the dataset. Unfortunately, despite overwhelming evidence that provision of an OG service is of benefit, it is presently challenging to recruit to this important specialty within the UK. Publicly available reports from the NHFD were obtained for each of the 177 participating hospitals for 2017. This was matched with information held within the annual NHFD Facilities Audit for the same period, which include hours of OG support for each hospital. This information was combined with a Freedom of Information request made by email to each hospital for further details concerning OG support. The outcome measures used were Length of Stay (LoS), mortality, and return to usual residence. Comparison was made with provision of OG services by use of Pearson's correlation coefficient. In addition, differences in services were compared between the 25% (44) hospitals delivering outcomes at the extremes for each measure. Attainment of BPT correlated fairly with LoS (−0.48) and to less of a degree with mortality (−0.1) and return home (0.05). Perioperative medical assessment contributed very strongly with BPT attainment (0.75). In turn perioperative medical assessment correlated fairly with LoS (−0.40) and mortality (−0.23) but not return home (0.02). Provision of perioperative medical assessment attainment was correlated fairly with total OG minutes available per new patient (0.22), total OG minutes available per patient per day (0.29) and number of days per week of OG cover (0.34); with no link for number of patients per orthogeriatrician (0.01). Mortality for the best units were associated with 30% more consultant OG time available per patient per day, and 51% more OG time available per patient. Units returning the most patients to their usual residence had little association with OG time, although had 59% fewer patients per OG, the best units had a 19% longer LoS. For all three measures results for the best had on average 0.5 days per week better routine OG access. There is no doubt that good quality care gives better results for this challenging group of patients. However, the interaction of BPT, other care metrics, level of OG support and patient factors with outcomes is complex. We have found OG time available per patient per day appears to influence particularly LoS and mortality. Options to increase OG time per patient include reducing patient numbers (ensuring community osteoporosis/falls prevention in place, including reducing in-patient falls); increasing OG time across the week (employing greater numbers/spreading availability over 7 days per week); and reducing LoS. A reduction in LoS has the largest effect of increasing OG time, and although it is dependent on OG support, it is only fairly correlated with this and many other factors play a part, which could be addressed in units under pressure.
Within healthcare, several measures are used to quantify and compare the severity of health conditions. Two common measures are disability weight (DW), a context-independent value representing severity of a health state, and utility weight (UW), a context-dependent measure of health-related quality of life. Neither of these measures have previously been determined for developmental dysplasia of the hip (DDH). The aim of this study is to determine the DW and country-specific UWs for DDH. A survey was created using three different methods to estimate the DW: a preference ranking exercise, time trade-off exercise, and visual analogue scale (VAS). Participants were fully licensed orthopaedic surgeons who were contacted through national and international orthopaedic organizations. A global DW was calculated using a random effects model through an inverse-variance approach. A UW was calculated for each country as one minus the country-specific DW composed of the time trade-off exercise and VAS.Aims
Methods
Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear.Aims
Methods
Hip fracture commonly affects the frailest patients, of whom many are care-dependent, with a disproportionate risk of contracting COVID-19. We examined the impact of COVID-19 infection on hip fracture mortality in England. We conducted a cohort study of patients with hip fracture recorded in the National Hip Fracture Database between 1 February 2019 and 31 October 2020 in England. Data were linked to Hospital Episode Statistics to quantify patient characteristics and comorbidities, Office for National Statistics mortality data, and Public Health England’s SARS-CoV-2 testing results. Multivariable Cox regression examined determinants of 90-day mortality. Excess mortality attributable to COVID-19 was quantified using Quasi-Poisson models.Aims
Methods
Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries.Aims
Methods
Orthopaedic surgeries are complex, frequently performed procedures associated with significant haemorrhage and perioperative blood transfusion. Given refinements in surgical techniques and changes to transfusion practices, we aim to describe contemporary transfusion practices in orthopaedic surgery in order to inform perioperative planning and blood banking requirements. We performed a retrospective cohort study of adult patients who underwent orthopaedic surgery at four Canadian hospitals between 2014 and 2016. We studied all patients admitted to hospital for nonarthroscopic joint surgeries, amputations, and fracture surgeries. For each surgery and surgical subgroup, we characterized the proportion of patients who received red blood cell (RBC) transfusion, the mean/median number of RBC units transfused, and exposure to platelets and plasma.Aims
Methods
Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis.Aims
Methods
The purpose of our study was to determine which groups of orthopaedic providers favour virtual care, and analyze overall orthopaedic provider perceptions of virtual care. We hypothesize that providers with less clinical experience will favour virtual care, and that orthopaedic providers overall will show increased preference for virtual care during the COVID-19 pandemic and decreased preference during non-pandemic circumstances. An orthopaedic research consortium at an academic medical system developed a survey examining provider perspectives regarding orthopaedic virtual care. Survey items were scored on a 1 to 5 Likert scale (1 = “strongly disagree”, 5 = “strongly agree”) and compared using nonparametric Mann-Whitney U test.Aims
Methods
Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances.Aims
Methods
Understanding the long-term effects of total knee arthroplasty (TKA) on joint kinematics is vital to assess the success of the implant design and surgical procedure. However, while Two fresh-frozen lower limbs from a single donor (male, age: 83yr, ht: 1.83m, wt: 86kg), who had undergone bilateral TKA (Genesis II, Smith&Nephew, Memphis, USA) 19 years prior to his demise, were obtained following ethical approval from the KU Leuven institutional board. The specimens were imaged using computed tomography (CT) and tested in a validated knee simulator3 replicating active squatting and varus-valgus laxity tests. Tibiofemoral kinematics were recorded using an optical motion capture system and compared to various studies in the literature using the same implant – experimental studies based on cadaveric specimens (CAD)1,4 and an artificial specimen (ART)5, and a computational study (COM)6. Maximum tibial abduction during laxity tests for the left leg (3.54°) was comparable to CAD (3.30°), while the right leg exhibited much larger joint laxity (8.52°). Both specimens exhibited valgus throughout squatting (left=2.03±0.57°, right=5.81±0.19°), with the change in tibial abduction over the range of flexion (left=1.89°, right=0.64°) comparable to literature (CAD=1.28°, COM=2.43°). The left leg was externally rotated (8.00±0.69°), while the right leg internally rotated (−15.35±1.50°), throughout squatting, with the change in tibial rotation over the range of flexion (left=2.61°, right=4.79°) comparable to literature (CAD=5.52°, COM=4.15°). Change in the femoral anteroposterior translation over the range of flexion during squatting for both specimens (left=14.88mm, right=6.76mm) was also comparable to literature (ART=13.40mm, COM=20.20mm). Although TKA was reportedly performed at the same time on both legs of the donor by the same surgeon, there was a stark difference in their post-operative joint kinematics. A larger extent of intraoperative collateral ligament release could be one of the potential reasons for higher post-operative joint laxity in the right leg. Relative changes in post-operative tibiofemoral kinematics over the range of squatting were similar to those reported in the literature. However, differences between absolute magnitudes of joint kinematics obtained in this study and findings from the literature could be attributed to different surgeons performing TKA, with presumable variations in alignment techniques and/or patient specific instrumentation, and the slightly dissimilar ranges of knee flexion during squatting. In conclusion, long-term kinematic effects of TKA quantified using