Femoral neck fractures are the second cause of hospitalization in elderly patients. Nowadays it is still not clear whether surgical treatment may provide better clinical outcome than conservative treatment in patients affected by mental disorders, such as senile dementia. The aim of this study was to retrospectively assess mortality and clinical and functional outcome after hemi arthroplasty operation following intracapsular neck fractures in patients with senile dementia. Between 2008 and 2014, 819 patients were treated at our Orthopaedic Institute for neck fracture of the femur (mean age: 83.8 years old). Eighty-four of these showed clear signs of cognitive impairment at time of admission in the Emergency Department. Mental state of patients was assessed in all cases, as routine, at the Emergency Room with the Short Portable Mental Status Questionnaire (Sh-MMT) and the Mini Mental State Examination (MMSE). Patients were divided in two groups depending whether they were surgically treated with hemiarthroplasty (Group B, 46 patients; 35 females, 11 males; mean age: 88.5 y.o.) or conservatively treated (Group C, 38 patients; 28 females, 10 males; mean age: 79.5 y.o.). These two groups were compared with a matched case-control group of patients surgically treated with no mental disorders (Group A, 40 patients; 34 females, 6 males; mean age: 81.5 y.o.) Incidence of mortality, systemic or local complications and functional clinical outcomes were evaluated with the ADL score and the Barthel index. Mortality rate was 35% (14 patients) for Group A, 50% (21 patients) for Group B and 95% (22 patients) for Group C. Paired t-test, with significance rate set at 0.05, showed significant higher mortality rate in Group A compared to both Group B ( Activity daily living scale and Barthel Index results showed higher results in Group B than Group C both in terms of recovery of walking ability and daily living (hairdressing, wearing clothes, eating).
Limb length discrepancy after total hip replacement is one of the possible complications of suboptimal positioning of the implant and cause of patients dissatisfaction. Computer assisted navigation become affirmed in last years for total hip replacement surgery and it is also used for the evaluation of the intra-operative limb length discrepancy. The purpose of this study is to verify the reliability of a navigation system with a dedicated software in intraoperative evaluation of limb lengthening and offset as compared with manual technique. Forty patients who underwent a Total Hip Arthroplasty in our institution were entrolled in this study. Twenty patients were evaluated with pre operative manual planning (group A) and treated with hand positioning of femoral stem. Twenty Patient were evaluated with preoperative manual planning and treated with Computer assisted navigation of Stem (group B). Mean operating time and blood loss were analyzed. Radiological and clinical follow up was made at 1, 3, 6 and 12 months postoperative to assess any mismatch of implant, complications and clinical results that was measured with Harris Hip Score.Background
Methods
The Segond's fracture is described as a cortical avulsion of the lateral tibial plateau at the site of insertion of the middle third of the lateral capsular ligament. The Segond's fracture is usually associated with a tear of the Anterior Cruciate Ligament (ACL) and it is considered as an indirect radiological sign of complete rupture of the ACL. However there are no studies investigating the effect of a Segond's fracture on the kinematic of the knee especially on the rotatory instability and Pivot Shift (PS) phenomenon. The purpose of this study is to investigate the effect of a Segond's fracture on the kinematic of the knee with the use of navigation and the PS test. Ten whole fresh-frozen cadavers were used. A navigator (2.0 Orthopilot Navigation System, BBraun Aesculap, Tuttlingen, Germany) was used to measure maximum manual Anterior Tibial Translation (ATT) at 30°, 60° and 90° of flexion, maximum manual Internal Rotation (IR) and maximum manual External Rotation (ER) at 0°, 15°, 30°, 45° and 90° of flexion. All procedures were performed three times and the mean value taken as the final result in each case. Moreover a PS test was performed by the senior, most experienced, surgeon, and graded as mild (gliding), moderate (jerk) and severe (subluxation). Navigation measurements and PS tests were performed in each knee with ACL intact, after arthroscopic cutting of the entire ACL and after a Segond's fracure was produced by exposing the antero lateral compartment of the knee underneath the ileo-tibial tract. Statistical analysis was performed using ANOVA 1-way and MANOVA tests and value for statistical analysis was set at p<0.05Introduction
Methods
Manual postoperative CT calculation of anteversion and inclination of the acetabular cup can be inaccurate and depends on the observer's experience. The aim of this study is to describe and present a validation of a new CT-image-based dedicate software (EGIT) for calculation of the acetabular component placement. The software principle is based on a three-dimensional reconstruction of a patient's bones from anatomical data collected postoperatively on the patient's CT scan. 15 Patient to be operated for THR were enrolled in this study. All patients were evaluated with post operative CT-scan. Measurement of Cup positioning were performed with two different methods: a manual method, performed by an expert radiologist, and a software CT image based method. Statistical analysis was performed with Intraclass Correlation Coefficent to asses interobserver and intraobserver reliability. A paired T-test was used to detect differences between manual and software methods. The Intraclass Correlation Coefficient was excellent for both the intraobserver and interobserver reliability. As expected the ICC is higher in the interobserver case. A mean cup anteversion of 14.2 (S.D. ±6.9), mean inclination of 44.2 (S.D.± 5.8) are detected with EGIT by the expert surgeon; Mean Cup anteversion of 13.6 (S.D. ± 5.11), mean inclination of 43.3 (S.D.± 5.1) are detected with manual method by expert radiologist. No statistical difference have been found (P> 0.05). The EGIT software seems to be an easy, accurate and reproducible method to calculate acetabular cup positioning using standard post-operative CT scan in THA.