Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 342 - 342
1 Sep 2012
Migaud H Marchetti E Combes A Puget J Tabutin J Pinoit Y Laffargue P
Full Access

Introduction

The same cup orientation is classically applied to all cases of hip replacement (45° abduction, 20° anteversion). We hypothesize that this orientation must be adapted to the patient's hip range of motion. We tested this hypothesis by means of an experimental study with respect to hip range of motion, comparing the classical orientation (45° and 20°), and the orientation obtained with computer-assisted navigation.

Material and Methods

The experimental model included a hemipelvis equipped with a femur whose mobility was controlled for three configurations: stiff (60°/0°, 15°/10°, 10°/10°), average (80°/10°, 35°/30°,35°/25°), mobile (130°/30°, 50°/50°, 45°/35°). The hemipelvis and the cup holder were equipped with an electromagnetic system (Fastrack ™) to measure cup orientation. The Pleos™ navigation system (equipping the hemipelvis, the femur, and the cup holder) guided the cup orientation by detecting the positions risking impingement through a kinematic study of the hip. Nine operators each performed 18 navigation-guided implantations (162 hip abduction, anteversion, and range of movement measurements) in two series scheduled 2 months apart.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 522 - 523
1 Nov 2011
Combes A Girard J Soenen M Krantz N Migaud H
Full Access

Purpose of the study: For young active patients, implantation of metal backed socket with a metal-on-metal bearing is an attractive tribological alternative when a standard prosthesis cannot be implanted. Metal ion assays have not been reported in this type of population. The purpose of this work was to present the clinical, radiographic and metal ion results.

Material and methods: Between 1998 and 2003 23 total hip arthroplasties (THA) (six primary and 17 revision) were implanted with a cemented Metasul™ bearing in a Muller inlay. Mean follow-up was 6.1 years (5–10). None of the patients was lost to follow-up. The Harris and PMA scores were noted as were signs of implant loosening or migration. Metal ions were assayed in total blood (Cr and Co) by mass spectrometry and atomic emission spectrometry (Ti).

Results: At follow-up, the mean Harris and PMA scores were significantly increased, from 62.2 to 95.2 (p = 0.01) and from 12.9 to 17.4 (p = 0.02) respectively. No revisions were required for aseptic loosening or failure of fixation. The radiographs did not reveal any signs of osteolysis or lucency. The mean levels of Cr, Co and Ti were 1.85μg/l (0.8–3.2). 1.24μg/l (0.5–1.86) and 9.62μg/l (5–18) respectively. Ti > 10μg/l was noted in six patients; Ti > 10 μg/l and Cr > 2μg/l in five patients. There was no correlation of metal ion levels with size of the implants, activity level, gender, clinical scores or cup inclination.

Discussion: The mean Co and Cr levels observed in this series were similar to those reported in the literature for standard THA (cementless press fit cups). Ti levels have only been reported in rare studies so that comparison with other series is hazardous. The Ti level observed here appeared to depend on the femoral stem resurfacing (in our series, the porous surface of the stem was coated with a Ti-6Al-7nB alloy).

Conclusion: Cementing the metal-on-metal bearing in the supporting inlay appears to be a reliable and attractive technique for this young and active population. Levels of Cr and Co in blood were the same as reported for standard implants. These levels of metal ions should be followed to confirm the long-term results.