Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 67 - 67
1 Dec 2022
Cohen D Le N Zakharia A Blackman B Slawaska-Eng D de SA D
Full Access

To determine in skeletally mature patients with a traumatic, first-time, patellar dislocation, the effect of early MPFL reconstruction versus rehabilitation on the rate of recurrent patellar dislocations and functional outcomes.

Three online databases MEDLINE, EMBASE and PubMed were searched from database inception (1946, 1974, 1966 respectively), to August 20th, 2021, for literature addressing the management of patients sustaining acute first-time patellar dislocations. Data on redislocation rates, functional outcomes using the Kujala score, and complication rates were recorded. A meta-analysis was used to pool the mean postoperative kujala score as well as calculate the proportion of patients sustaining redislocation episodes using a random effects model. A risk of bias assessment was performed for all included studies using the MINORS and Detsky scores.

Overall, there were a total of 22 studies and 1705 patients included in this review. The pooled mean redislocation rate in 18 studies comprising 1409 patients in the rehabilitation group was 31% (95% CI 25%-36%, I2 = 65%). Moreover, the pooled mean redislocation rate in five studies comprising 318 patients undergoing early MPFL reconstruction was 7% (95% CI 2%-17%, I2 = 70%). The pooled mean postoperative Kujala anterior knee pain score in three studies comprising 67 patients in the reconstructive group was 91 (95% CI 84-97, I2 = 86%), compared to a score of 81 (95% CI 78-85, I2 = 78%) in 7 studies comprising 332 patients in the rehabilitation group. The reoperation rate was 9.0% in 936 patients in the rehabilitation group and 2.2% in 322 patients in the reconstruction group.

Management of acute first-time patellar dislocations with MPFL reconstruction resulted in a lower rate of redislocation and a higher Kujala score, as well as noninferiority with respect to complication rates compared to nonoperative treatment. The paucity of high-level evidence warrants further investigation in this topic in the form of well-designed and high-powered RCTs to determine the optimal management option in these patients.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 485 - 494
1 Apr 2020
Gu A Malahias M Selemon NA Wei C Gerhard EF Cohen JS Fassihi SC Stake S Bernstein SL Chen AZ Sculco TP Cross MB Liu J Ast MP Sculco PK

Aims

The aim of this study was to determine the impact of the severity of anaemia on postoperative complications following total hip arthroplasty (THA) and total knee arthroplasty (TKA).

Methods

A retrospective cohort study was conducted using the American College of Surgeons National Quality Improvement Program (ACS-NSQIP) database. All patients who underwent primary TKA or THA between January 2012 and December 2017 were identified and stratified based upon hematocrit level. In this analysis, we defined anaemia as packed cell volume (Hct) < 36% for women and < 39% for men, and further stratified anaemia as mild anaemia (Hct 33% to 36% for women, Hct 33% to 39% for men), and moderate to severe (Hct < 33% for both men and women). Univariate and multivariate analyses were used to evaluate the incidence of multiple adverse events within 30 days of arthroplasty.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 59 - 59
1 Feb 2017
Campbell D Sharpe K Cohen R
Full Access

Introduction

Cementless tapered wedge stems have shown excellent results over the last decade. Distal potting with inadequate proximal fit, as well as failure to achieve biologic fixation has led to thigh pain, loosening and implant failure. To support a variety of patient morphologies a novel tapered wedge stem was designed with reduced distal morphology, maximizing the proximal contact of the grit blasted surface. The objective of the study was to analyze the clinical outcomes of this stem design.

Methods

Three hundred and nineteen patients enrolled into prospective, post-market multicenter studies received a novel tapered wedge stem. Clinical and patient-reported outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and Euroqol 5D Score (EQ-5D) were evaluated preoperative through two years postoperative.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 85 - 85
1 Feb 2017
Cruz A Perona P Cohen R Campbell D
Full Access

Background

Instability and dislocation are some of the most important postoperative complications and potential causes of failure that dual mobility total hip arthroplasty (THA) systems continue to address. Studies have shown that increasing the relative head size provides patients implanted with smaller and larger cups increased stability, greater ROM and a lesser incidence of impingement, without compromising clinical results. The purpose of the current study was to review clinical outcomes in three groups of primary THA patients receiving a dual mobility acetabular shell.

Methods

In two US based, post-market, multicenter studies, 450 patients received a primary cementless dual mobility THA. Patients were split into three groups based on cup size: ≤ 50mm, 52mm–56mm, and ≥ 58mm. Harris Hip Scores (HHS), Short Form 12 Physical Components (SF12 PCS), Lower Extremity Activity Scores (LEAS), and Euroqol 5D Score (EQ-5Ds) were collected preoperatively and through 2 years postoperative.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 76 - 76
1 May 2016
Duplantier N Rivere A Cohen A Chimento G
Full Access

Background

Joint replacement surgery has been shown to be successful in post solid organ transplantation patients. However, complication rates, revision rates, and overall mortality can be higher in this population compared to patients who have not undergone solid organ transplantation. Many transplant patients have a decreased life expectancy. Therefore, literature suggests that joint replacement surgery be offered to qualifying patients early on when symptomatic. This study compares the outcomes of patients who have undergone solid organ transplantation as well as a joint replacement to patients that have only undergone joint replacement surgery.

Methods

We retrospectively gathered 42 transplant (T) patients over a ten year period, 2003–2013, that underwent a liver (21) or kidney (21) transplant as well as primary total knee arthroplasty (TKA) (23) or total hip arthroplasty (THA) (19). We then gathered 42 non-transplant (NT) patients matched for procedure, age, body mass index (BMI), American Society of Anesthesiologists (ASA) score, and age adjusted Charlson co-morbidity index (ACCI) score who only underwent TKA or THA with no transplant. We used Chi-Square, T test, and multivariate analysis to compare the two groups with regard to number of complications (NOC), readmissions at 30 and 90 days post surgery, length of stay (LOS), number of intensive care unit (ICU) admissions, and total direct cost (TDC) per hospital stay.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 45 - 45
1 Dec 2015
Finelli C Dell Aquila A Miki-Rosario N Fernandes H Dos Reis F Cohen M Abdalla R Da Silva C Murça M Nigro S Salles M
Full Access

Intramedullary nailing (IMN) has been frequently indicated to treat long bone open and closed fractures, but infection following internal fixation may have devastating consequences, with higher costs. Treatment of intramedullary nail-associated infections (IMNI) is challenging and based upon surgery and adequate antibiotic administration, which requires the correct identification of causative microorganisms. However, there have been difficulties for the microbial diagnosis of IMNI, as the peri-prosthetic tissue cultures may show no microbial growth, particularly in patients with previous use of antibiotics. Sonication have shown higher sensitivity and specificity for microbial identification on a variety of orthopedic implant-associated infections. Aim: To compare clinical and microbiological results and sensitivity for the pathogen identification obtained by conventional peri-implant tissue culture samples with culture of samples obtained by sonication of explanted IMN implants, among patients presenting IMNI of long bones.

Methods: Longitudinal prospective cohort study performed at a tertiary public hospital, ongoing since August 2011. We analyzed all patients with indication for IMN implant removal, and orthopedic-implant associated infections was defined according to previous publications addressing osteosynthesis-associated infections (Yano 2014). Minimal of 2 samples from the peri-implant tissue were taken and sent under sterile conditions to the laboratory for culture. Statistical analysis was performed McNemar's test for related proportions.

Results: We included 26 patients presenting clinical signs of IMNI, of which tissue and sonication cultures were performed for 26 (100%) and 20 (77%) patients, respectively. Among them, 88% were male, with mean age was 35.9 years (range, 19–59 yo). Causes of trauma were mainly motorcycle crashes accounting 54% of accidents; tibia and fibula were affected in 65% and 27%, respectively. Gustilo open fracture classification was grade II (35%) and IIIA (35%). First stage management with external fixation for fracture stabilization was performed in 75% of trauma patients. Sensitivity of peri-prosthetic tissue culture and sonication was 80.7% (21/26), and 95% (19/20) (p< 0.05), respectively. Only one infected patient presented negative tissue and fluid cultures. Gram-positive cocci were isolated in 75% and 79% in tissue and sonication fluid cultures, respectively. Staphylococcus aureus, coagulase-negative staphylococci, Enterococcus sp., were isolated from tissue and sonication culture in 43.5% and 36.3%, 8.7% and 22.7%, 13% and 13.7%, respectively. Polymicrobial infection was diagnosed in 3.8% (1/26) and 15.8% (3/19), patients by tissue and sonication fluid cultures (p< 0,01), respectively.

Conclusion: Sonication of retrieved infected intramedullary nails has the potential for improving the microbiological diagnosis of IMNI.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 105 - 105
1 Dec 2015
Metsemakers W Emanuel N Cohen O Reichart M Schmid T Segal D Richards R Zaat S Moriarty T
Full Access

One of the most challenging complications in orthopedic trauma surgery is the development of infection. Improved infection prophylaxis could be achieved by providing local delivery of antibiotics directly to the tissue-implant interface. Especially implant-associated bone infections caused by antibiotic-resistant pathogens pose significant clinical challenges to treating physicians. Prophylactic strategies that act against resistant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA), are urgently required.

The objective of this experimental study was to determine the efficacy of a biodegradable Polymer-Lipid Encapsulation MatriX (PLEX) loaded with the antibiotic doxycycline as a local prophylactic strategy against implant-associated osteomyelitis in a humeral non-fracture rabbit model.

Activity of the PLEX-doxycycline-coating was tested against both a doxycycline susceptible (doxyS) methicillin-susceptible S. aureus (MSSA) as well as a doxycycline-resistant (doxyR) MRSA. In a rabbit intramedullary (IM) nail-related infection model, twelve rabbits received an inoculum of a doxyS MSSA direct into the medullary cavity of the humerus. After inoculation, animals received either a PLEX-doxycycline-coated nail, or an uncoated nail. The animals were observed for four weeks. Upon euthanasia, quantitative bacteriology was performed to determine bacterial load in tissues and biofilm formation on the implant. A second study was performed with sixteen rabbits receiving a DoxyR MRSA inoculum, again in coated and uncoated groups.

In vitro elution studies revealed that 25% of the doxycycline was released from the PLEX-coated implants within the first day, followed by a 3% release per day up to day 28. Quantitative bacteriology revealed the presence of osteomyelitis in all animals receiving an uncoated nail in both the MSSA and the DoxyR MRSA studies (figure). All rabbits receiving a PLEX-doxycycline-coated nail were culture negative in the doxyS MSSA-group and the surrounding bone displayed a normal physiological appearance in both histological sections and radiographs. In the doxyR MRSA inoculated rabbits, a statistically significant reduction in the number of culture-positive samples was observed for the PLEX-doxycycline-coated group when compared to the animals that had received an uncoated nail, although the reduction in bacterial burden did not reach statistical significance.

Improved prophylaxis against infection in trauma and orthopedic implant surgery is clearly required today. In this study, we investigated a PLEX-doxycycline-coated IM nail in a humeral non-fracture rabbit model. The PLEX-doxycycline coating on titanium alloy implants provided complete protection against implant-associated MSSA osteomyelitis, and resulted in a significant reduction in the number of culture positive samples when challenged with a doxycycline-resistant MRSA.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 12 - 12
1 Nov 2015
Cohen B
Full Access

The primary goals of successful rTSA (Reverse Total Shoulder Arthroplasty) are pain relief, improved shoulder motion and function with the restoration of patient independence. These goals can be achieved by optimal prosthesis design and surgical technique.

Historically there have been two predominant reverse shoulder design philosophies: the traditional valgus 155-degree neck-shaft angle with a medialised center of rotation introduced by Dr. Grammont, and the more recent varus 135-degree neck-shaft angle with a lateralised center of rotation, developed by Dr. Frankle. The latter design has reported lower incidences of scapular notching, coupled with improved adduction and external rotation. Over time, an understanding of the factors which resulted in clinical complications and those that contributed to the clinical success of both these design philosophies has been analyzed and widely publicised. With the currently available reverse prostheses the surgeon is required to be committed to one design philosophy or the other. This commitment to one singular design may hinder surgeons from the ability to individualise each case regardless of patient anatomy, rotator cuff condition, arthritic state and post-operative expectation.

Recently, a system has been launched which offers both design philosophies in one system, providing unsurpassed intra-operative flexibility. This allows the surgeon to adapt to each individual case and choose either design philosophy based on patient condition and anatomy, thus optimizing patient outcome.

The treatment of proximal humeral fractures has historically included Hemi Arthroplasty (HA) or Total Shoulder Arthroplasty (TSA). However, rTSA has recently become the surgery of choice for many fracture treatments based on more reproducible results. Certain implant characteristics are gaining favor in the treatment of proximal humerus fractures namely:

Press fit humeral stems - which avoid the risks of cement in-between the tuberosities which has been reported to compromise healing.

Proximal ‘box-shape’ geometry - which enables rotational stability especially in cases with proximal bone loss to promote reconstruction leading to improved healing.

135-degree neck-shaft angle - allowing a higher and more anatomic tuberosity position for more stable fixation maintains anatomical integrity of the tuberosities which has been reported as a critical factor for retaining rotator cuff function.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 267 - 267
1 Dec 2013
Cohen R
Full Access

Cementless biologic fixation surfaces on total joint replacement devices, such as those used in total hip and knee procedures, have evolved over the decades. Historically, various surfaces to allow bone ingrowth or ongrowth have been applied as a coating to a pre-formed solid metal substrate. As shown in Figure 1, from left to right, representative coating surfaces include sintered beads, diffusion-bonded fiber metal, and plasma sprayed titanium. In certain applications, tantalum porous metal (Fig 1, left) can be used without a solid metal substrate, but its most widespread usage is in a modular acetabular cup design with the porous metal diffusion-bonded to a solid metal substrate similar to other coatings. Each of these examples of biologic fixation surfaces has limitations. With comparatively low porosity, bead, fiber metal and plasma spray coatings are simply a surface enhancement onto a rigid machined, forged or cast metal substrate. Furthermore, the thermal process to apply the coatings can adversely affect the mechanical properties of the metal substrate. Released in the 1990's, tantalum porous metal is considered a ‘highly porous metal’ with twice the porosity of the applied surface coatings. With that greater porosity comes lower strength that requires engineers to make standalone tantalum porous metal shapes more bulky. The chemical deposition process to produce tantalum porous metal shapes has also limitations on geometry possibilities. Where bonding the tantalum porous metal to a solid metal substrate is necessary for adequate strength, that diffusion bonding process pressure can diminish the surface coefficient of friction necessary for initial stability.

A new class of manufacturing processing, referred to as ‘additive manufacturing’, allows engineers to create unique porous configurations. These configurations can be fabricated with beneficial properties to a specific implant application. One such enabling additive manufacturing process is called direct metal laser sintering (DMLS). This process utilizes a laser that travels over a fine powder bed. The laser path is determined by a program that mimics a computer model. Where the laser contacts the powder bed, the powder consolidates. Layer by layer, a scaffold porous metal is fabricated. Figure 2 shows a titanium alloy porous metal structure produced by DMLS. This formed biomaterial has 65% porosity, a high coefficient of friction, low stiffness, and strength that is 2 to 3 times that of tantalum porous metal. From a design versatility perspective, with greater strength, relatively thinner and more bone conserving geometries can be developed. When a solid metal surface interface to secure a modular polymer bearing is required, the DMLS process can produce the solid surface and the porous metal at the same time. With no secondary bonding thermal cycle needed, the construct's mechanical integrity is not compromised. Advancing biologic fixation necessitates bone conserving implant designs that have the properties to achieve immediate mechanical stability and longer term bone ingrowth. This novel use of DMLS in this particular porous metal geometry allows engineers to meet those criteria.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 331 - 331
1 Mar 2013
Cohen R Skrepnik N
Full Access

Various reports confirm that elevations in serum markers associated with skeletal muscle injury exist and can occur after orthopaedic surgery in the absence of overt clinical manifestations of myocardial injury. The purpose of this study is to measure the influence surgical approach on these serum markers following primary Minimally Invasive THA. Consecutive enrollment of 30 patients into three different groups of 10 was performed. The MIS Modified Watson Jones THA is an approach using an inter-muscular plane, the Mini Posterior is a trans-muscular approach with some muscle detachment and repair, while the MIS II Incision THA is an inter-muscular approach anteriorly and a trans-muscular approach posteriorly. Blood samples for total creatine kinase (CK), creatine phospho-kinase (CPK), and serum myoglobin were obtained at screening and the morning before surgery as a baseline, immediately post-operatively in the recovery room and 8, 16, 24, 36, 48, and 72 hours post-operatively. Hemoglobin and hematocrit was obtained pre-operatively, 16, 36, and 72 hours (±6 hours) post-operatively. Cardiac troponin-I was measured the morning before surgery (pre-operatively) and 16 hours following surgery to monitor any contributory effect of myocardial injury. We report measurable and reproducible trends in serum enzyme levels consistent with skeletal muscle damage due to THA. Troponin-I remained normal in all but one case throughout the entire study indicating no myocardial contribution to measured serum enzyme levels. While these trends may have slight correlation with surgical approach, they were not statistically significant. We conclude that all three procedures do affect serum enzyme markers and are safe from this standpoint, but no surgical approach appears to affect the degree of muscle trauma more or less than another.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 41 - 41
1 Mar 2013
Cohen R Skrepnik N Katz J Maltry J Housman LR Slagis S Eberle R
Full Access

The purpose of this study was to compare the clinical, radiographic, and DEXA results of Epoch® Femoral Component for primary THA with other non-cemented femoral components. The Epoch and Epoch 14+ (Zimmer, Warsaw, IN) Composite Femoral Components were studied in conjunction with the VerSys® Fiber Metal Taper, Fiber Metal Mid coat and Beaded Fullcoat Femoral Components (Zimmer, Warsaw, IN). All patients were randomized into one of five component groups and followed prospectively. All patients across the five groups were matched with respect to demographics and body mass index (BMI) (Table 1). Diagnoses were evenly distributed across all study groups. There was no significant change in BMD at 5-years when compared to the baseline (6 month) DEXA measurements for all component groups except for the Beaded Fullcoat component subset which had significant decreases in BMD in proximal zones 1, 6 and 7, The Fiber Metal Taper showed similar decreases in BMD in zones 1 and 7, and the Epoch Component had a significant decrease in BMD in zone 7 only. Additionally, our DEXA findings complement and support the subjective radiographic interpretations performed for this study cohort. The results from this prospective, randomized controlled clinical trial showed that the Epoch Composite Femoral Component for primary THA can achieve results equal to standard alloy components of varying design. Based on these early results, the Epoch and Epoch 14+ Femoral Components for primary THA are justified for continuance of further prospective study.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 42 - 42
1 Mar 2013
Cohen R
Full Access

Modularity of femoral components has been widely accepted at the head neck junction, most commonly combining two unlike metals with only sporadic reporting of compatibility issues and corrosion. The development and introduction of a new and improved modular neck junction (Rejuvenate Modular Femoral component, Stryker Orthopedics) provided the option of fine-tuning leg lengths, offset and stability. The surgical technique did indeed provide the desired endpoints, however, the early recognition of problems with the junction causing corrosion and Adverse Local Soft Tissue Reaction (ALTR) and subsequent revision has led to the product being voluntarily withdrawn from the market. My experience as an early user of this stem is described in this manuscript providing a better early recognition and treatment of this potentially very destructive process.

Methods

A retrospective review of one hundred and ninety one Rejuvenate Stems that were implanted between January 2010 and January of 2012. However, after March 2011, this stem was only used on those patients who had a rejuvenate stem on the contralateral side. They were all implanted through a mini posterior incision with the first 82 patients receiving a Tritanium cluster hole cup (Stryker Orthopedics) with between two and three screws. The remaining 109 patients had an ADM (Anatomic Dual Mobility, Stryker Orthopedics). All patients were allowed to bear weight as tolerated and were followed up with Xrays at six weeks and one year. Clinical visits were recorded at 2 weeks and 6 months postop. Additional follow up was scheduled every two years following the first annual visit.

Results

One hundred and seventy four of the 191 hips were available for review at the one-year follow-up. Fourteen patients have undergone revision of the hip due to increased pain and formation of an avascular pseudo capsule due to corrosion at the neck stem junction. All patients have demonstrated a black flaky residue at the taper junction and all have had a large, tense effusion with a milky colored fluid. A neo caspsule has formed in all patients that appeared avascular and thickened. Seven of the eight tritanium cups in the revision cases were loose and required revision, while none of the ADM cups were loose. One patient has undergone two revisions since the initial cause of failure was not recognized and she subsequently developed pain within three months following placement of a new modular neck at the initial revision. One patient who underwent revision developed a deep infection and is currently on antibiotics but has not cleared the infection as of this writing.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 1 - 1
1 Mar 2013
Leeper A Brandon P Morgan A Cutts S Cohen A
Full Access

Fascia iliaca compartment block (FIB), performed in the Emergency Department (A&E) in patients presenting with femoral neck fracture, has gained increasing recognition as an adjunctive analgesic. The purpose of this study was to investigate whether FIB significantly reduced the requirement for systemic opiates in the pre-operative setting. Analgesia requirements for all patients admitted with fractured neck of femur to one unit over a four month period were gathered prospectively. 33% patients had received FIB at diagnosis in ED, dependant on the expertise of the attending physician. Morphine requirements on arrival on the ward between groups were analysed. Over a four month period 144 patients were admitted with fractured neck of femur. Over this time period, introduction of an informal educational programme in A&E increased the incidence of FIB provision at diagnosis and reduced the average amount of morphine administered. Administration of FIB reduced the average morphine requirement in A&E by 56%, when compared with those who received systemic analgesia alone (CI 0.4–3.5, p=0.014). No adverse effects were reported with FIB. Fascia Iliaca Compartment Block is a safe and effective method of providing analgesia to patients with fractured neck of femur and reduces morphine requirement.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 134 - 134
1 Sep 2012
Lindau T Bainbridge C Cohen B Kushner H Smith T Nguyen D Szczypa P Gerber R
Full Access

Introduction

Injectable collagenase clostridium histolyticum (CCH) is a minimally invasive non-surgical therapy with efficacy in correcting Dupuytren's contracture (DC). In the concurrently run JOINT I and JOINT II studies, designed to follow clinical practice, we evaluated the efficacy of ?5 CCH injections in patients with DC.

Methods

JOINT I and II were multicenter, 9-month, open-label studies in which DC patients with primary flexion deformities ?20° received ?3 CCH (0.58 mg) injections/joint (?5 injections/patient) at 30-day intervals into joints prioritized by extent of contracture. After the first injection, patients could opt to receive up to 2 additional injections in same cord or other cords regardless of outcome for the first joint. The primary endpoint was reduction in contracture to ?5° 30 days after the last injection. Data from JOINT I and II were pooled.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 157 - 157
1 Sep 2012
Singhal R Perry D Khan F Cohen D Stevenson H James L Sampath J Bruce C
Full Access

Background

Establishing the diagnosis in a child presenting with an atraumatic limp can be difficult. Clinical prediction algorithms have been devised to distinguish septic arthritis (SA) from transient synovitis (TS). Within Europe measurement of the Erythrocyte Sedimentation Rate (ESR) has largely been replaced with assessment of C-Reactive Protein (CRP) as an acute phase protein. We produce a prediction algorithm to determine the significance of CRP in distinguishing between TS and SA.

Method

All children with a presentation of ‘atraumatic limp’ and a proven effusion on hip ultrasound between 2004 and 2009 were included. Patient demographics, details of the clinical presentation and laboratory investigations were documented to identify a response to each of the four variables (Weight bearing status, WCC >12,000 cells/m3, CRP >20mg/L and Temperature >38.5°C). SA was defined based upon culture and microscopy of the operative findings.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 72 - 72
1 Sep 2012
Cohen D Cartwright-Terry M Pope J Davidson J Santini A
Full Access

Purpose

To review the outcomes of patients undergoing manipulation under anaesthetic (MUA) after primary total knee arthroplasty (TKA) and predict those that may require such a procedure.

Methods

Prospective analysis of patients who required MUA post TKA performed by two surgeons using the same prosthesis from 2003 to 2008. Compared to a control group of primary TKA matched for age, gender and surgeon. All patients in both groups had pre- and post-operative measurements of range of movement. Risk factors were identified including warfarin and statin use, diabetes and body mass index.