header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 88 - 88
23 Feb 2023
Petterwood J McMahon S Coffey S Slotkin E Ponder C Wakelin E Orsi A Plaskos C
Full Access

Smartphone-based apps that measure step-count and patient reported outcomes (PROMs) are being increasingly used to quantify recovery in total hip arthroplasty (THA). However, optimum patient-specific activity level before and during THA early-recovery is not well characterised. This study investigated 1) correlations between step-count and PROMs and 2) how patient demographics impact step-count preoperatively and during early postoperative recovery.

Smartphone step-count and PROM data from 554 THA patients was retrospectively reviewed. Mean age was 64±10yr, BMI was 29±13kg/m2, 56% were female. Mean daily step count was calculated over three time-windows: 60 days prior to surgery (preop), 5-6 weeks postop (6wk), and 11-12 weeks postop (12wk).

Linear correlations between step-count and HOOS12 Function and UCLA activity scores were performed. Patients were separated into three step-count levels: low (<2500steps/day), medium (2500-5500steps/day), and high (>5500steps/day). Age >65years, BMI >30, and sex were used for demographic comparisons.

Student's t-tests determined significant differences in mean step-counts between demographic groups and in mean PROMs between step-count groups.

UCLA correlated with step-count at all time-windows (p<0.01). HOOS12 Function correlated with step-count preoperatively and at 6wk (p<0.01). High vs low step count individuals had improved UCLA scores preoperatively (∆1.8,p<0.001), at 6wk (∆1.1,p<0.05), and 12wk (∆1.6,p<0.01), and improved HOOS12 Function scores preoperatively (∆8.4,p<0.05) and at 6wk (∆8.8,p<0.001).

Younger patients had greater step-count preoperatively (4.1±3.0k vs 3.0±2.5k, p<0.01) and at 12wk (5.1±3.3k vs 3.6±2.9k, p<0.01). Males had greater step-count preoperatively (4.1±3.0k vs. 3.0±2.7k, p<0.001), at 6wk (4.5±3.2k vs 2.6±2.5k, p<0.001), and at 12wk (5.2±3.6k vs. 3.4±2.5k, p<0.001). Low BMI patients had greater step-count at 6wk (4.3±3.3k vs. 2.6±2.7k, p<0.01) and 12wk (5.0±3.6k vs. 3.6±2.6k, p<0.05).

Daily step-count is significantly impacted by patient demographics and correlates with PROMs, where patients with high step count exhibit improved PROMs. Generic recovery profiles may therefore not be appropriate for benchmarking across diverse populations.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 49 - 49
23 Feb 2023
Sorial R Coffey S Callary S
Full Access

Roentgen Stereophotogrammetric Analysis (RSA) is the gold standard for measuring implant micromotion thereby predicting implant loosening. Early migration has been associated with the risk of long-term clinical failure. We used RSA to assess the stability of the Australian designed cementless hip stem (Paragon TM) and now report our 5-year results.

Fifty-three patients were prospectively and consecutively enrolled to receive a Paragon hip replacement. Tantalum beads were inserted into the bone as per RSA protocol and in the implant. RSA x-rays were taken at baseline 1–4 days post-surgery, at 6 weeks, 6 months, 12 months, 2 years, and 5 years. RSA was completed by an experienced, independent assessor.

We reported the 2-year results on 46 hips (ANZJS 91 (3) March 2021 p398) and now present the 5-year results on 27 hips. From the 2-year cohort 5 patients had died, 8 patients were uncontactable, 1 patient was too unwell to attend, 5 patients had relocated too far away and declined. At 5 years the mean axial subsidence of the stem was 0.66mm (0.05 to 2.96); the mean rotation into retroversion was 0.49˚ (−0.78˚ to 2.09˚), rotation of the stem into valgus was −0.23˚ (−0.627˚ to 1.56˚). There was no detectable increase in subsidence or rotation between 6 weeks and 5 years. We compared our data to that published for the Corail cementless stem and a similar pattern of migration was noted, however greater rotational stability was achieved with the Paragon stem over a comparable follow-up period.

The RSA results confirm that any minor motion of the Paragon cementless stem occurs in the first 6 weeks after which there is sustained stability for the next 5 years. The combination of a bi-planar wedge and transverse rectangular geometry provide excellent implant stability that is comparable to or better than other leading cementless stems.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 87 - 87
23 Feb 2023
Orsi A Wakelin E Plaskos C McMahon S Coffey S
Full Access

Inverse Kinematic Alignment (iKA) and Gap Balancing (GB) aim to achieve a balanced TKA via component alignment. However, iKA aims to recreate the native joint line versus resecting the tibia perpendicular to the mechanical axis. This study aims to compare how two alignment methods impact 1) gap balance and laxity throughout flexion and 2) the coronal plane alignment of the knee (CPAK).

Two surgeons performed 75 robotic assisted iKA TKA's using a cruciate retaining implant. An anatomic tibial resection restored the native joint line. A digital joint tensioner measured laxity throughout flexion prior to femoral resection. Femoral component position was adjusted using predictive planning to optimize balance. After femoral resection, final joint laxity was collected. Planned GB (pGB) was simulated for all cases posthoc using a neutral tibial resection and adjusting femoral position to optimize balance. Differences in ML balance, laxity, and CPAK were compared between planned iKA (piKA) and pGB. ML balance and laxity were also compared between piKA and final (fiKA).

piKA and pGB had similar ML balance and laxity, with mean differences <0.4mm. piKA more closely replicated native MPTA (Native=86.9±2.8°, piKA=87.8±1.8°, pGB=90±0°) and native LDFA (Native=87.5±2.7°, piKA=88.9±3°, pGB=90.8±3.5°). piKA planned for a more native CPAK distribution, with the most common types being II (22.7%), I (20%), III (18.7%), IV (18.7%) and V (18.7%). Most pGB knees were type V (28.4%), VII (37.8%), and III (16.2). fiKA and piKA had similar ML balance and laxity, however fiKA was more variable in midflexion and flexion (p<0.01).

Although ML balance and laxity were similar between piKA and pGB, piKA better restored native joint line and CPAK type. The bulk of pGB knees were moved into types V, VII, and III due to the neutral tibial cut. Surgeons should be cognizant of how these differing alignment strategies affect knee phenotype.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 103 - 103
10 Feb 2023
Petterwood J Sullivan J Coffey S McMahon S Wakelin E Plaskos C Orsi A
Full Access

Preoperative ligament laxity can be characterized intraoperatively using digital robotic tensioners. Understanding how preoperative knee joint laxity affects preoperative and early post-operative patient reported outcomes (PROMs) may aid surgeons in tailoring intra-operative balance and laxity to optimize outcomes for specific patients.

This study aims to determine if preoperative ligament laxity is associated with PROMs, and if laxity thresholds impact PROMs during early post-operative recovery.

106 patients were retrospectively reviewed. BMI was 31±7kg/m2. Mean age was 67±8 years. 69% were female. Medial and lateral knee joint laxity was measured intraoperatively using a digital robotic ligament tensioning device after a preliminary tibial resection.

Linear regressions between laxity and KOOS12-function were performed in extension (10°), midflexion (45°), and flexion (90°) at preoperative, 6-week, and 3-month time points. Patients were separated into two laxity groups: ≥7 mm laxity and <7 mm laxity. Student's t-tests determined significant differences between laxity groups for KOOS12-function scores at all time points.

Correlations were found between preoperative KOOS12-function and medial laxity in midflexion (p<0.001) and flexion (p<0.01). Patients with <7 mm of medial laxity had greater preoperative KOOS12-function scores compared to patients with ≥7 mm of medial laxity in extension (46.8±18.2 vs. 29.5±15.6, p<0.05), midflexion (48.4±17.8 vs. 32±16.1, p<0.001), and flexion (47.7±18.3 vs. 32.6±14.7, p<0.01). No differences in KOOS12-function scores were observed between medial laxity groups at 6-weeks or 3-months. All knees had <5 mm of medial laxity postoperatively. No correlations were found between lateral laxity and KOOS12-function.

Patients with preoperative medial laxity ≥7 mm had lower preoperative PROMs scores compared to patients with <7 mm of medial laxity. No differences in PROMs were observed between laxity groups at 6 weeks or 3 months. Patients with excessive preoperative joint laxity achieve similar PROMs scores to those without excessive laxity after undergoing gap balancing TKA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 104 - 104
10 Feb 2023
McMahon S Coffey S Sullivan J Petterwood J Ponder C Slotkin E Wakelin E Orsi A Plaskos C
Full Access

Passive smartphone-based apps are becoming more common for measuring patient progress after total knee arthroplasty (TKA). Optimum activity levels during early TKA recovery haven't been well documented. This study investigated correlations between step-count and patient reported outcome measures (PROMs) and how demographics impact step-count preoperatively and during early post-operative recovery.

Smartphone capture step-count data from 357 TKA patients was retrospectively reviewed. Mean age was 68±8years. 61% were female. Mean BMI was 31±6kg/m2. Mean daily step count was calculated over three time-windows: 60 days prior to surgery (preop), 5-6 weeks postop (6wk), and 11-12 weeks postop (12wk).

Linear correlations between step-count and KOOS12-function and UCLA activity scores were performed. Patients were separated into three step-count levels: low (<1500steps/day), medium (1500-4000steps/day), and high (>4000steps/day). Age >65years, BMI >30kg/m2, and sex were used for demographic comparisons.

Student's t-tests determined significant differences in mean step-counts between demographic groups, and in mean PROMs between step-count groups.

UCLA correlated with step-count at all time-windows (p<0.01). KOOS12-Function correlated with step-count at 6wk and 12wk (p<0.05). High step-count individuals had improved PROMs compared to low step-count individuals preoperatively (UCLA: ∆1.4 [p<0.001], KOOS12-Function: ∆7.3 [p<0.05]), at 6wk (UCLA: ∆1 [p<0.01], KOOS12-Function: ∆7 [p<0.05]), and at 12wk (UCLA: ∆0.8 [p<0.05], KOOS12-Function: ∆6.5 [p<0.05]).

Younger patients had greater step-count preoperatively (3.8±3.0k vs. 2.5±2.3k, p<0.01), at 6wk (3.1±2.9k vs. 2.2±2.3k, p<0.05) and at 12wk (3.9±2.6k vs. 2.8±2.6k, p<0.01). Males had greater step-count preoperatively (3.7±2.6k vs. 2.5±2.6k, p<0.001), at 6wk (3.6±2.6k vs. 1.9±2.4k, p<0.001), and at 12wk (3.9±2.3 vs. 2.8±2.8k, p<0.01). No differences in step-count were observed between low and high BMI patients at any timepoint.

High step count led to improved PROMs scores compared to low step-count. Early post-operative step-count was significantly impacted by age and sex. Generic recovery profiles may not be appropriate across a diverse population.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 216 - 216
1 Mar 2010
Stoita R Coffey S
Full Access

The Less Invasive Stabilisation System (LISS) was introduced with the aim to decrease the incidence of fracture nonunion and the need for primary bone grafting. We aim to describe the cases of nonunion of osteoporotic distal femoral fractures treated with the LISS at our institution and to review the cases of nonunion published in the literature.

Three cases of nonunion of osteoporotic distal femoral fractures treated with the LISS at our institution were identified. A thorough retrospective analysis of the available clinical information was performed. To identify all published papers on LISS, an exhaustive literature search was performed. The Medline and PubMed databases were searched for the following keywords: femoral fractures, distal femoral fractures, supracondylar, LISS, less invasive stabilization system and femoral no nunions. The search period was 1996 to 2008. All relevant studies were analysed.

Low energy trauma was responsible for the closed fractures encountered in our patients. Two patients sustained fractures around a joint arthroplasty: one fracture above a total knee arthroplasty and one fracture below a total hip arthroplasty. The operative technique consisted of indirect reduction on the traction table and minimally invasive percutaneous osteosynthesis. The postoperative radiographic alignment was satisfactory for all fractures. Aseptic nonunion was diagnosed in all patients. Implant failure occurred in two patients with fracture of the proximal screws in one case and fracture of the distal screws in the second case. No case s of failure of distal locking screws have previously been described in the literature. No other complications were identified. The literature search identified 21 cases of fracture nonunion. Six of these fractures occurred in osteoporotic bones as a result of low energy trauma. All 6 fractures were above a total knee arthroplasty.

The LISS is a new implant who has shown good results in the management of difficult distal femoral fractures. Its use is however not without problems: concerns with regards to inadequate or excessive rigidity and a demanding surgical technique are just some of the issues.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 197 - 198
1 Mar 2010
Hanslow S Sorial R Coffey S Sunner P Gan J
Full Access

Malalignment of knee arthroplasty components can lead to abnormal wear, premature loosening and patellofemoral problems. Computer assisted surgery has been developed to improve surgeons ability to achieve correct alignment and thereby improve outcomes. This project compares the accuracy of computer assisted total knee arthroplasty with a conventional jig-assisted technique.

A total of 150 patients were recruited. Selection criteria included patients presenting with degenerative or inflammatory joint disease who were candidates for total knee arthroplasty. Patients having revision procedures were excluded as were patients who previously had a corrective osteotomy. Ethics approval was obtained and patients consented for the study. Patients were randomly allocated to either the computer navigated or jig alignment groups via the sealed envelope system. Demographic patient data and intraoperative data were collected. Quality of life and function assessments made using the WOMAC and Knee Society Scores. The component position was assessed using the Perth CT protocol.

One hundred and fifty patients were recruited from Dec 2005 to July 2007. Five patients were excluded due to machine malfunction and two others were excluded due to insufficient data collected leaving 143 patients for the study. There was no difference in blood loss, post operative hemoglobin or patient length of hospital stay. There was no difference in the Knee Society knee or function scores at 12 weeks or the knee flexion range either at discharge or at 3 months follow up. There was a significant correlation in duration of surgery (p< 0.05) with the navigated cases taking an average 23 minutes longer. Both the conventional jig alignment and computer navigated techniques produced accurate results in all CT measurements except for the tibial slope where the navigated group (4.8+/−1.6) was closer to the elected posterior slope of 3.5+/− 1.5 than the jig system (6.4+/−2). Statistically significant differences in favour of the navigated group were also found for both femoral component rotation and tibial coronal alignment but the outliers beyond the accepted ideal alignment of 0+/−3 degrees for each parameter were minimal and equivalent for the two groups.

Computer navigation in knee replacement surgery is gaining popularity to improve component alignment and consequently the outcome of total knee arthroplasty. This study has shown only marginal benefits in alignment of the navigated group but this needs to be considered against the increased surgical time despite familiarity with the hardware.