Vol. 96-B, Issue SUPP_18 | Pages 13 - 13
1 Dec 2014
Nademi M Naikoti K Salloum W Jones HW Clayson A Shah N
Full Access

Stoppa approach has recently been adapted for pelvic surgery as it allows direct intra-pelvic reduction and fixation of the quadrilateral plate and anterior column. We report our early experience, indications and complications with this exposure introduced in 2010 in our tertiary unit.

A Retrospective review of all Stoppa approaches in pelvic-acetabular fixations was performed from a prospectively maintained database.

Of the 25 patients, mean age 40 years (range 15–76), who underwent pelvic-acetabular fixation using Stoppa approach, 21 patients had mean follow up of 7.3 months (1–48 months). All except 24% of patients had one or more additional systemic injury some requiring additional surgery. There were 6 acetabular fractures, 13 pelvic ring injuries and 6 combined fractures. Mean injury-surgery interval was 9 days (range 3–20). 8 patients had an isolated Stoppa approach whilst the remaining others also had an additional approach. Mean surgical time was 239 minutes. Anatomical reduction was achieved in 96% (24/25) cases. There was 1 minor intra-operative vascular injury, repaired immediately successfully, and no late wound infections, or other visceral complications. One patient reported new onset sensory numbness which resolved after the first review. Two patients reported erectile dysfunction thought to be caused by the initial injury. One patient had asymptomatic plate loosening. None required revision surgery.

Despite the obvious learning curve, we found this approach safe and it did not compromise accuracy of reduction in well selected patients, but early surgery within 10–14 days is recommended to aid optimal reduction.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 28 - 28
1 Dec 2014
Naikoti KK Sylvan A WynnJones H Shah N Clayson A
Full Access

The radiological evidence of implant failure following plate fixation of traumatic pubic symphysis diastasis can be up to 75%. We report the complications following symphyseal double orthogonal plating in patients with pubic symphysis diastasis over a period of 2.5 years. Patient records and radiographs of 38 consecutive patients were reviewed with mean follow up of 12.5 months. 5 patients (13%) had radiological evidence of implant failure with one patient (2.6%) requiring revision surgery. There was no evidence of wound complications. We conclude that our lower rate of revision surgery and metal work failure is attributed to double orthogonal plating.