Proponents of the direct anterior approach (DAA) for hip arthroplasty (THA) claim lower postoperative pain compared to the posterolateral approach (PA); however, whether that theoretical advantage results in lower opioid consumption is unclear. We sought to investigate the relationship between the DAA and PA on total 90-day predicted opioid consumption in a large cohort. Retrospective analysis identified 2,304 DAA and 6,288 PA primary THAs in patients >18 years old from February 2019 to April 2022. Ninety-day postoperative total morphine milligram equivalent (MME); in-hospital administration, discharge prescriptions, and refills within 90 days were compared between DAA and PA cohorts. Nearest-neighbor matching was performed controlling for age, sex, BMI, ASA, and periarticular injection to evaluate opioid consumption patterns for DAA and PA. Quantile regression was employed to predict the median (50th percentile) MME prescribed by surgical approach. After matching, DAA and PA demonstrated similar median total 90-day prescribed MME ( While we identified several risk factors for increased in-hospital and 90-day post-operative opioid consumption, a comparison between DAA and PA did not demonstrate significantly different opioid prescribing patterns.
Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.Aims
Methods
Due to the opioid epidemic, our service developed a cultural change highlighted by decreasing discharge opioids after lower extremity arthroplasty. However, concern of potentially increasing refill requests exists. As such, the goal of this study was to analyze whether decreased discharge opioids led to increased postoperative opioid refills. We retrospectively reviewed 19,428 patients undergoing a primary hip or knee arthroplasty at a single institution from 2016–2019. Patients that underwent secondary procedures within that timeframe were excluded. Two-thousand two-hundred and forty-one patients (12%) were on narcotics preoperatively or had chronic pain syndrome. Two reductions in routine discharge narcotics were performed over this timeframe. First, 8,898 patients routinely received 750 morphine milligram equivalents (MMEs). After the first reduction, 4,842 patients routinely received 520 MMEs. After a second reduction, 5,688 patients routinely received 320 MMEs. We analyzed refill rates, refill MMEs, and whether discharge MMEs were associated with refill MMEs in a multivariate model.Introduction
Methods
Modular dual-mobility constructs reduce the risk of dislocation after revision total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chromium (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the early- to mid-term serum Co and Cr levels after modular dual-mobility components were used in revision and complex primary THAs, and specifically included patients revised for ALTR. Serum Co and Cr levels were measured prospectively in 24 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. The mean age was 63 years (35 to 83), with 13 patients (54%) being female. The mean follow-up was four years (2 to 7). Indications for modular dual-mobility were prosthetic joint infection treated with two-stage exchange and subsequent reimplantation (n = 8), ALTR revision (n = 7), complex primary THA (n = 7), recurrent instability (n = 1), and periprosthetic femoral fracture (n = 1). The mean preoperative Co and Cr in patients revised for an ALTR were 29.7 μg/l (2 to 146) and 21.5 μg/l (1 to 113), respectively.Aims
Patients and Methods
Modular dual-mobility constructs reduce the risk of dislocation after total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chrome (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the mid-term serum Co and Cr levels after modular dual-mobilities used in revision and complex primary THAs, and specifically included patients revised for ALTR. Serum Co and Cr levels were measured prospectively in 22 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. Mean age 64 years with 50% female. The mean follow-up was 4 years. Indications for modular dual-mobility were: periprosthetic joint infection treated with 2-stage exchange and subsequent reimplantation (n=8), ALTR revision (n=7), complex primary THA (n=6), and periprosthetic femoral fracture (n=1). Mean preoperative Co and Cr in patients revised for an ALTR were 29.7 µg/L and 21.5 µg/L, respectively.Introduction
Methods