The management of femoral bone loss is challenging during revision hip arthroplasty. In patients with Paprosky grade IIIB and IV defects, obtaining fixation and rotational stability using traditional surgical constructs is difficult. The use of a custom-made internal proximal femoral replacement prostheses has been proposed as a solution in patients, with severe femoral bone stock loss. However, there is a paucity in the literature on their use and long-term outcomes. We report on the clinical and radiological results of our cohort. We retrospectively reviewed all patients who underwent internal proximal femoral replacement for revision hip arthroplasty between April 1996 and April 2019. All patients had at least 2 years of follow-up time. 160 patients underwent limb salvage at our institution using internal proximal femoral replacement. The mean follow-up was 79.7 months (S.D 41.3). Indications for revision included periprosthetic fractures, aseptic loosening, and deep infection. The mean Oxford hip score increased from 13.8 (0–22) to 31.5 (18–43) (paired t-test, p < 0.001). Kaplan-Meier prosthesis survival analysis with revision as the endpoint was 87% at 5 years. None required revision of the femoral stem. There were four dislocations (5%) and there was failure to eradicate the deep infection in four. This technique allows instant distal fixation, allowing for early mobilisation. Long-term clinical and radiological outcomes are encouraging and the complication rates are acceptable for this patient group.
Autologous chondrocyte implantation is a NICE approved intervention however it involves the morbidity of two operations, a prolonged rehabilitation and substantial healthcare costs. This study describes a novel, one-step, bone marrow (BM) derived mesenchymal stem cell (MSC) transplantation technique for treating knee osteochondral lesions and presents our prospective clinical study investigating the success of this technique in 206 lesions over a 5 year period. The surgical technique involves harvesting BM from patients’ anterior superior iliac spines, centrifugation to isolate MSCs and seeding into a type 1 collagen scaffold (SyngenitTM Biomatrix). Autologous fibrin glue is used to secure the scaffold into the defect. Inclusion criteria included patients aged 15 – 55 years old with symptomatic osteochondral lesions >1cm2. Exclusion criteria included patients with ligament instability, uncorrected alignment, inflammatory arthropathy and a Body Mass Index >35 kg/m2. Outcome measures included the Modified Cincinnati Knee Rating System (MCKRS), complications and reoperations.Abstract
Background
Methodology
Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed.Abstract
Introduction
Methodology
Custom acetabular components have become an established method of treating massive acetabular bone defects in hip arthroplasty. Complication rates, however, remain high and migration of the cup is still reported. Ischial screw fixation (IF) has been demonstrated to improve mechanical stability for non-custom, revision arthroplasty cup fixation. We hypothesise that ischial fixation through the flange of a custom acetabular component aids in anti-rotational stability and prevention of cup migration. Electronic patient records were used to identify a consecutive series of 49 custom implants in 46 patients from 2016 to 2022 in a unit specializing in complex joint reconstruction. IF was defined as a minimum of one screw inserted into the ischium passing through a hole in a flange on the custom cup. The mean follow-up time was 30 months. IF was used in 36 cups. There was no IF in 13 cups. No difference was found between groups in age (68.9 vs. 66.3, P = 0.48), BMI (32.3 vs. 28.2, P = 0.11) or number of consecutively implanted cups (3.2 vs. 3.6, P = 0.43). Aseptic loosening with massive bone loss was the primary indication for revision. There existed no difference in Paprosky grade between the groups (P = 0.1). 14.2% of hips underwent revision and 22.4% had at least one dislocation event. No ischial fixation was associated with a higher risk of cup migration (6/13 vs. 2/36, X2 = 11.5, P = 0.0007). Cup migration was associated with an increased risk for all cause revision (4/8 vs. 3/38, X2 = 9.96, P = 0.0016, but not with dislocation (3/8 vs. 8/41, X2 = 1.2, P = 0.26). The results suggest that failure to achieve adequate ischial fixation, with screws passing through the flange of the custom component into the ischium, increases the risk of cup migration, which, in turn, is a risk factor for revision.
The primary aim of this study was to evaluate the outcomes of fungal knee periprosthetic joint infection following knee arthroplasty. The secondary aim was to evaluate risk factors for acquiring a fungal PJI. This was a retrospective analysis of patients presenting with a confirmed fungal PJI of the knee in two tertiary centres. There were a total of 45 cases. Isolated fungal infections along with mixed bacterial and fungal infections were included. Mean follow up was 40 months (range 3–118).Abstract
Aims
Patients and Methods
Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure. This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt.Background
Methods
Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim. Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR).Background
Methods
Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of surgical training, it is harder for junior trainees to gain exposure to these operations, resulting in reduced practice. Additionally, methods of simulation using workshop bones do not utilise the imaging component due to the associated radiation risks. We present a digital fluoroscopy software, FluoroSim, a realistic, affordable, and accessible fluoroscopic simulation tool that can be used with workshop bones to simulate the first step of the DHS procedure. Additionally, we present the first round of accuracy tests with this software. The software was developed at the Royal National Orthopaedic Hospital, London, England. Two orthogonally placed cameras were used to track two coloured markers attached to a DHS guide-wire. Affine transformation matrices were used in both the anterior-posterior (AP) and cross table lateral (CTL) planes to match three points from the camera image of the workshop bone to three points on a pre-loaded hip radiograph. The two centre points of each marker were identified with image processing algorithms and utilised to digitally produce a line representing the guide-wire on the two radiographs. To test the accuracy of the system, the software generated 3D guide-wire apex distance (GAD) (from the tip of the guide-wire to a marker at the centre of calibration) was compared to the same distance measured with a digital calliper (MGAD). In addition, the same accuracy value was determined in a simulation scenario, from 406 attempts by 67 medical students.Background
Methods
The Birmingham Hip Resurfacing (Smith & Nephew London, UK) is the most popular hip resurfacing (HR) in the UK. However, it is now subject to two Medical Device Alerts (MDA) from the Medicines and Healthcare products Regulatory Agency (MHRA). A cross-sectional survey of primary metal-on-metal hip procedures recorded on the National Joint Registry for England, Wales and Northern Ireland (NJR) until 5th November 2013 was performed. Cost-analysis was based on an algorithm for surveillance of HR at a tertiary referral centre and followed previous MHRA guidance. NIHR NHS Treatment costs were used. The local protocol encompassed: patient outcome scoring (Oxford hip score), blood metal ion measurement (cobalt, chromium), cross-sectional imaging (MRI) and discussion at an internet-enabled multidisciplinary team meeting (iMDT) in addition to routine hip surveillance.Introduction
Patients/Materials & Methods
THR is one of the most frequently performed operations nationally. A large number of prostheses are available, and the procedure is therefore associated with variation in practice and outcomes. NICE guidelines aim to standardise best practice, and are informed by separate, independent bodies, such as the NJR and ODEP, which monitor data about the implants used and their performance. This study aims to determine whether clinical practice and component use has changed since the publication of NJR data. NJR reports from 2006–2014 were analysed, with record made of the different prostheses used in THR, noting ODEP ratings of components used. Analysis was also performed by component type (i.e. cemented and cementless stems and cups), and combinations of components, according to their frequency of use in a given year. The Kruksal-Wallis test was used for statistical analysis.Introduction
Methods
Surgical simulation and ‘virtual’ surgical tools are becoming recognised as essential aids for speciality training in Trauma & Orthopaedics, as evidenced by the BOA T&O Simulation Curriculum 20131,2. The current generation of hip arthroplasty simulators, including cadaveric workshops, offers the trainee limited exposure to reproducible real life bony pathology. We developed and implemented a novel training course using pathological dry bone models generated from real patient cases to support senior orthopaedic trainees and new consultants in developing knowledge and hands on skills in complex total hip arthroplasty. A two-day programme for 20 delegates was held at a specialist centre for hip arthroplasty. Three complex femoral and three complex acetabular cases were identified from patients seen at our centre. 3D models were printed from CT scans and dry bone models produced (using a mold-casting process), enabling each delegate to have a copy of each case at a cost of around £30 per case per delegate (Figure 1). The faculty was led by 4 senior Consultant revision hip surgeons. A computerised digitising arm was used to measure cup positioning and femoral stem version giving candidates immediate objective feedback (Figure 2). Candidate experience and satisfaction with the course and models was evaluated with a standardised post-course questionnaire.Introduction
Patient/Materials & Methods
Uncertainties in the management of patients with MOM hip implants continue to be a problem for all surgeons. Guidelines vary and do not fully define or quantify thresholds. We aimed to assess the differences in decision-making amongst an international community of six specialist orthopaedic institutions. Five international tertiary referral orthopaedic units (one UK, two USA, and two European) were invited to participate. Each unit organised an MDT panel consisting of 2 or more hip surgeons and a musculoskeletal radiologist. All units discussed the same 10 patients. A full clinical dataset was provided including blood test and all imaging. Differences in the interpretation of findings, management decision and rationale for decisions were compared between institutions.Introduction
Methods
The Royal National Orthopaedic Hospital has completed an extensive trial of ACI versus MACI in the treatment of symptomatic osteochondral defects of the knee. A new technique has now been proposed which is quicker and easier to perform. This is the Gel-Type Autologous Chondrocyte Transplantation, CHONDRONTM. At Stanmore CHONDRON has been used for the past 17 months. Our aim was to assess the short term functional outcome of patients who have undergone CHONDRONTM using validated outcome scoring questionnaires. We retrospectively reviewed the notes of 43 patients that had undergone CHONDRONTM over one year ago and scored them using the Modified Cincinnati Score, the Visual Analogue Score and the Benltey Stanmore Functional Rating Score. The mean pre-operative Modified Cincinnati Score was 39.9, which improved to a mean of 59.8 post-operatively. The mean Visual Analogue Score improved from 6.7 to 5.1 post-operatively. The median Bentley Functional Rating Score was 3 pre-operatively and 2 post-operatively. These early results show that 76% of the patients who were treated with CHONDRONTM experienced a reduction in pain and improvement in post-operative function. In the patients in whom the symptoms were worse, the deterioration in score could be partly explained by numerous previous procedures on the same site, presence of early osteoarthritis or the presence of multiple osteochondral lesions. This highlights the importance of careful patient selection in order to gain maximum benefit from the procedure.RESULTS
CONCLUSIONS
Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included achondroplasia, spondyloepiphyseal dysplasia, pseudoachondroplasia, multiple epiphyseal dysplasia, morquio syndrome, diastrophic dysplasia and Larson's Syndrome. Patients were followed clinically and radiographically for a mean of 7 years (range, 3–11.5 years). Knee pain and function improved in all 11 joints. Mean Knee Society clinical and function scores improved from 24 (range, 14–36) and 20 points (range, 5–40) preoperatively to 68 (range, 28–80) and 50 points (range, 22–74) respectively at final follow-up. Four complications were recorded (36%), including a patellar fracture following a fall, a tibial periprosthetic fracture, persistent anterior knee pain and a femoral component revision for aseptic loosening. Our results suggest that custom rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, optimising movement and improving function. It compensates for bony deformity and ligament deficiency and reduces the need for corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than primary TKR in the general population. Submission endorsed by Mr Peter Calder, Consultant Orthopaedic Surgeon and Society member
The aim of this study was to see if the evaluation of the initial postoperative radiograph following primary knee and hip arthroplasty correlated with clinical outcome at five years postoperatively. Using our institution database we identified forty-nine hip replacements and fifty-two knee replacements performed between 2000 and 2006. All the patients underwent postoperative radiographs one day after surgery and clinical evaluation up to at least five years postoperatively. A consultant radiologist evaluated the radiographs for alignment and component position. The hip arthroplasty patients were assessed clinically using the Harris hip score, Oxford hip score, and the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). The knee arthroplasty patients were assessed using the Knee Society score, Oxford knee score, and the WOMAC score.Introduction
Methodology
The Enhanced Recovery Programme (ERP) is an evidence based initiative aimed at speeding up patient recovery after major surgery and improving their outcomes. The Royal National Orthopaedic Hospital, Stanmore (RNOH) is a specialist orthopaedic and implemented an ERP for primary knee arthroplasties from October 2010. To analyse the initial results of patients participating in our ERP for primary knee arthroplasty to identify what factors predict their Length of Stay (LoS) and establish where changes can be made to improve outcomes further.Background
Aims
Infection after knee arthroplasty is a devastating complication. Our aim is to present our outcomes of treating infected knee replacements at a tertiary referral centre. We performed a consecutive, retrospective case series of all revision knee arthroplasty for infection between January 2006 and December 2008. Case notes were reviewed and data collated on the date and institution of primary arthroplasty, procedures undertaken at our institution, microbiology and bone loss post first stage, serological markers (C-reactive protein, ESR) prior to second stage and outcome. During this three year period we performed 430 knee revision operations. 51 were in the presence of deep chronic infection. 90% were referred from other hospitals. Overall infection was successfully eradicated in 69%. Nineteen patients underwent repeat two-stage and overall eleven (58%) patients had successful eradication of infection with multiple two-stages. Of these 47% had F3/T3, the highest grading of Anderson Orthopaedic Research Institute bone loss indicating no metaphyseal bone. A further 12% had bicondylar deficiency on the tibia and no femoral metaphyseal bone (F3/T2b). Multidrug resistance present in 69% and 47% were infected with multiple organisms. All members of the unsuccessful outcome group had at least one multidrug resistant organism compared to 43% in the successful cohort (P=0.0002). Multiple organisms are associated with an unsuccessful outcome (P=0.056). Serological markers were not significantly different between the successful and unsuccessful outcome groups. Where the referring hospital had attempted revision and failed, the chance of eradicating infection dropped from 75% to 58% and the rate of above knee amputation was twelve times higher (3% vs. 36%). Custom constrained, rotating hinge prostheses enable aggressive soft tissue debridement including ligaments. Successful two-stage requires a multidisciplinary approach including tissue viability nurses, microbiologists and plastic surgeons. Where units lack revision expertise this series suggests early referral increases the chance of limb salvage.
Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome. The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010. The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 409 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites. High failure rates were noted in those with previous cartilage regenerative procedures or evidence of early osteoarthritis and those with transplantation to multiple sites. Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.
Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome. The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010. The majority of patients had several interim scores performed at varying intervals. The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 486 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites. 30% failed following this procedure at a mean time of 72 months. 52% patients stated a marked improvement in their functional outcomes within the first two years. 49% stated an excellent result following their procedure. High failure rate was noted in those with previous cartilage regenerative procedures, transplants occurring on the patella, particularly if involving multifacets. Multiple site cartilage transplantation was also associated with a high failure rate. Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.
It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome. A retrospective study of patients undergoing primary THR at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires after a minimum follow-up of 11 months. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. A factorial linear regression model was used to analyse data.Background
Methods