Clavicle fractures are common, yet debate exists regarding which patients would benefit from conservative versus operative management. Traditionally shortening greater than 2cm has been accepted as an indicator for surgery. However, clavicle length varies between individuals. In a cadaveric study clavicle shortening greater than 15% was suggested to affect outcomes. There is no clinical correlation of this in the literature. In this study we investigate outcomes following middle third clavicle fractures and the effect of percentage shortening on union rates. We identified a consecutive series of adults with primary midshaft clavicle fractures presenting to our institution from April 2015-March 2017. Clinical records and radiographs were reviewed to elicit outcomes. Time to union was measured against factors including; percentage shortening, displacement, comminution and smoking. Statistical significance was calculated.Abstract
Objectives
Methods
Operative management of distal humerus fractures is challenging. In the past, plates were manually contoured intraoperatively, however this was associated with high rates of fixation failure, nonunion and metalwork removal. Anatomically pre-contoured distal humerus locking plates have since been developed. Owing to the rarity of distal humeral fractures, literature regarding outcomes of anatomically pre-contoured locking plates is lacking and patient numbers are often small. The purpose of this study is to investigate the outcomes of these patients. We retrospectively identified patients with distal humeral fractures treated at our institution from 2009–2018. Inclusion criteria were patients with a distal humeral fracture, who underwent two-column plate fixation with anatomically pre-contoured locking plates. Clinical records and radiographs were reviewed to elicit outcome measures, including range of motion, complications and reoperation rate.Abstract
Objectives
Methods