Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1481 - 1487
1 Nov 2015
van der Veen HC Reininga IHF Zijlstra WP Boomsma MF Bulstra SK van Raay JJAM

We compared the incidence of pseudotumours after large head metal-on-metal (MoM) total hip arthroplasty (THA) with that after conventional metal-on-polyethylene (MoP) THA and assessed the predisposing factors to pseudotumour formation.

From a previous randomised controlled trial which compared large head (38 mm to 60 mm) cementless MoM THA with conventional head (28 mm) cementless MoP THA, 93 patients (96 THAs: 41 MoM (21 males, 20 females, mean age of 64 years, standard deviation (sd) 4) and 55 MoP (25 males, 30 females, mean age of 65 years, sd 5) were recruited after a mean follow-up of 50 months (36 to 64).

The incidence of pseudotumours, measured using a standardised CT protocol was 22 (53.7%) after MoM THA and 12 (21.8%) after MoP THA. Women with a MoM THA were more likely to develop a pseudotumour than those with a MoP THA (15 vs 7, odds ratio (OR) = 13.4, p < 0.001). There was a similar incidence of pseudotumours in men with MoM THAs and those with MoP THAs (7 vs 5, OR = 2.1, p = 0.30). Elevated cobalt levels (≥ 5 microgram/L) were only associated with pseudotumours in women with a MoM THA. There was no difference in mean Oxford and Harris hip scores between patients with a pseudotumour and those without.

Contrary to popular belief, pseudotumours occur frequently around MoP THAs. Women with a MoM THA and an elevated cobalt level are at greatest risk. In this study, pseudotumours had no effect on the functional outcome after either large head MoM or conventional MoP THA.

Cite this article: Bone Joint J 2015;97-B:1481–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1540 - 1545
1 Nov 2014
Dierselhuis EF van den Eerden PJM Hoekstra HJ Bulstra SK Suurmeijer AJH Jutte PC

Atypical cartilaginous tumours are usually treated by curettage. The purpose of this study was to show that radiofrequency ablation was an effective alternative treatment.

We enrolled 20 patients (two male, 18 female, mean age 56 years (36 to 72) in a proof-of-principle study. After inclusion, biopsy and radiofrequency ablation were performed, followed three months later by curettage and adjuvant phenolisation. The primary endpoint was the proportional necrosis in the retrieved material. Secondary endpoints were correlation with the findings on gadolinium enhanced MRI, functional outcome and complications.

Our results show that 95% to 100% necrosis was obtained in 14 of the 20 patients. MRI had a 91% sensitivity and 67% specificity for detecting residual tumour after curettage. The mean functional outcome (MSTS) score six weeks after radiofrequency ablation was 27.1 (23 to 30) compared with 18.1 (12 to 25) after curettage (p < 0.001). No complications occurred after ablation, while two patients developed a pathological fracture after curettage.

We have shown that radiofrequency ablation is capable of completely eradicating cartilaginous tumour cells in selective cases. MRI has a 91% sensitivity for detecting any residual tumour. Radiofrequency ablation can be performed on an outpatient basis allowing a rapid return to normal activities. If it can be made more effective, it has the potential to provide better local control, while improving functional outcome.

Cite this article: Bone Joint J 2014;96-B:1540–5.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 321 - 321
1 Jul 2011
Hosman AH van der Mei HC Bulstra SK Busscher HJ Neut D
Full Access

Background and Purpose: The remarkably low wear of metal-on-metal (MOM) bearings involving cobalt-chromium (Co-Cr) alloys has led to a resurgence in its use. However, consequences of these wear particles and the corrosion products are for the most part unclear. Recent research efforts towards the bacteriological influences of the MOM-degradation products suggested that particulate MOM debris promotes planktonic bacterial growth. On the other hand, extremely high concentrations of metal ions, derived from salts, have shown to possess bacteriostatic effects (growth reduction) on planktonic growth and on biofilm formation. The effects of salt-derived metal ions were found to be inhibitory and not bactericidal (lethal to bacteria). However, these two findings were both found under static growth conditions and no studies have investigated these findings under more clinically resembling dynamic growth conditions. In addition, influences of Co-Cr particles on biofilm formation have not yet been studied. Therefore, the aim of this study was to evaluate how Co-Cr particles and Co-Cr ions affect biofilm formation under static and dynamic growth conditions.

Methods: A collection of clinically isolated bacterial strains were exposed to Co-Cr particles and Co-Cr ions in concentrations as found in serum and above as found in adjacent tissue. The experiments were conducted as well under static, as under dynamic growth conditions. Biofilm formation in wells, stained with live/dead viability staining and visualized by confocal laser scanning microscopy, was analyzed with COMSTAT, yielding biovolume, biofilm thickness, and live/dead ratio of the bacteria within the biofilm.

Results: Co-Cr particle concentrations of 20 g/L reduced biofilm formation significantly. Moreover, these particle concentrations were found to be bactericidal (killed the bacteria). The live/dead ratio decreased when culturing was done under dynamic growth conditions when compared to the static growth condition. Under both growth conditions, biofilm formation was inhibited at concentrations of 10/5 mg/L Co-Cr ions, as reported to occur in synovial fluids. Co-Cr ion concentrations up to 1/0,5 mg/L revealed no consistent influence on biofilm formation.

Interpretation: Long-term clinical data on infection rates for Co-Cr MOM-bearings are not yet available, but the current results suggest that Co-Cr ions may yield these prostheses less prone to biofilm formation and subsequent infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 710 - 718
1 Jul 1999
Geesink RGT Hoefnagels NHM Bulstra SK

We performed a prospective, randomised double-blind study in 24 patients undergoing high tibial osteotomy to evaluate the effectiveness of human recombinant osteogenic protein (OP-1) on a collagen type-I carrier in a critically-sized fibular defect. The study had two phases, each evaluated by clinical, radiological and DEXA methods during the first postoperative year. The first concerned the validation of the model of the fibular defect, using positive (demineralised bone) and negative (untreated) controls. The second phase concerned the osteogenic potential of OP-1 on collagen type-I ν collagen type-I alone.

The results of the first phase established the critically-sized nature of the defect. In the untreated group no bony changes were observed while, in the demineralised bone group, formation of new bone was visible from six weeks onwards. The results of the second phase showed no significant formation of new bone in the presence of collagen alone, while in the OP-1 group, all patients except one showed formation of new bone from six weeks onwards. This proved the osteogenic activity of OP-1 in a validated critically-sized human defect.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 437 - 440
1 May 1998
Douw CM Bulstra SK Vandenbroucke J Geesink RGT Vermeulen A

We describe six knees in five patients, referred to us after accidental irrigation with chlorhexidine 1% in aqueous solution during arthroscopy.

All six knees developed persisting pain, swelling and crepitus with loss of range of movement. Radiographs showed loss of joint space in all three compartments due to extensive chondrolysis, with many loose bodies and synovitis. Histological examination showed partial necrosis of the cartilage, with slight non-specific inflammation and fibrosis of synovial specimens.

Care is needed in checking irrigation fluids, and these should have a distinctive colour.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 892 - 898
1 Nov 1996
Bulstra SK Geesink RGT Bakker D Bulstra TH Bouwmeester SJM van der Linden AJ

We have investigated the use of a conically-shaped cement plug made of Polyactive (PA), a biodegradable copolymer. The flexibility and hydrogel properties were thought to facilitate occlusion of the femoral canal even when it was oval or irregular in shape. The function of the plug was first compared with that of the Thackray polyethylene model in 16 artificial plastic femora.

The maximum intramedullary pressure achieved during cementing was ten times higher with the biodegradable model. Migration or leakage of cement did not occur when the diameter of the femoral canal was equal to or smaller than the diameter of the plug. We also showed that the biodegradable properties of this implant were such that it did not require removal during revision.

The new plug was tested in a pilot clinical trial. At two years only two out of 21 patients had evidence of migration or leakage of cement, probably due to a mismatch in the size of plug and femoral canal. There were no local changes in the femur.