Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 1 - 1
1 Jul 2020
Fernquest S Palmer A Gimpel M Birchall R Broomfield J Wedatilake T Dijkstra H Lloyd T Pereira C Newman S Carr A Glyn-Jones S
Full Access

Background

Cam morphology develops during adolescence and predisposes individuals to future hip pain and osteoarthritis. An improved understanding of cam development is required to determine whether the process is modifiable.

Hypothesis/Purpose

The aim of this study was to characterise the risk factors, timing, and pathogenesis of cam formation.


Bone & Joint Research
Vol. 7, Issue 7 | Pages 440 - 446
1 Jul 2018
Woods AK Broomfield J Monk P Vollrath F Glyn-Jones S

Objectives

The aim of this study was to investigate the structural integrity of torn and non-torn human acetabular labral tissue.

Methods

A total of 47 human labral specimens were obtained from a biobank. These included 22 torn specimens and 25 control specimens from patients undergoing total hip arthroplasty with macroscopically normal labra. The specimens underwent dynamic shear analysis using a rheometer to measure storage modulus, as an indicator of structural integrity.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 37 - 37
1 May 2018
Ferguson R Broomfield J Malak T Palmer A Whitwell D Taylor A Glyn-Jones S
Full Access

Background

Short bone-conserving femoral stem implants were developed to achieve more physiological, proximal bone loading than conventional femoral stems. Concerns have arisen, however, that improved loading may be offset by lower primary stability because of the reduced potential area for bony contact.

Aims

The aim of this study was to determine the primary stability of a novel short femoral stem compared with a conventional femoral stem following cementless total hip arthroplasty (THA), in a prospective, blinded, randomised, controlled trial using radiostereometric analysis.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 41 - 48
1 Apr 2017
Fernquest S Arnold C Palmer A Broomfield J Denton J Taylor A Glyn-Jones S

Aims

The aim of this study was to examine the real time in vivo kinematics of the hip in patients with cam-type femoroacetabular impingement (FAI).

Patients and Methods

A total of 50 patients (83 hips) underwent 4D dynamic CT scanning of the hip, producing real time osseous models of the pelvis and femur being moved through flexion, adduction, and internal rotation. The location and size of the cam deformity and its relationship to the angle of flexion of the hip and pelvic tilt, and the position of impingement were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 144 - 144
1 Sep 2012
Broomfield J Ralte P Neophytou C Waseem M
Full Access

Since November 2003 there have been 62 Metacarpophalangeal Joint (MCPJ) replacements carried out on 16 patients at Macclesfield District general hospital. 11 of the patients were female and 5 were male. The mean patient age at procedure was 64.9 years, with an age range of 28 to 80. Of the 62 MCPJ replacements carried out, 58 (93.5%) were as a result of rheumatoid arthritis, with only 4 (6.5%) as a result of osteo-arthritis. The primary objective of this study is to assess their outcomes to date. Data was collected retrospectively by means of case note review. Outcomes measured were patient rating of pain and function at post operative review and post operative complications. All operations were carried out by a single surgeon, using his standard operative technique, and all replacements used the Neuflex Finger Joint Implant System. All 16 patients attended for post operative review. At the time of discharge 13 patients rated their outcome as excellent to good, 1 patient was deceased and 2 patients are currently under follow up with no reported complications. Mean time to discharge was 19 months (2–68). Of the total 62 joints replaced, 10 revisions were carried out. Of these, 3 were as a result of dislocation, 6 were for subluxation and 1 as a result of failure of the prosthesis. There were 3 other post operative complications; 1 was for superficial wound infection, 1 resulting from a prominent prosthesis and 1 hypertrophic scar. Results showed that 81.3% of patients rated their range of movement as good to excellent and 87.5% reported an improvement in pain. Overall, 81% of patients rated their outcome at discharge as good to excellent. From the data available we conclude that the Neuflex system is an effective treatment method with a low complication rate.