We present the indications and outcomes of a series of custom 3D printed titanium acetabular implants used over a 9 year period at our institution (Sydney, Australia), in the setting of revision total hip arthroplasty. Individualised image-based case planning with additive manufacturing of pelvic components was combined with screw fixation and off-the-shelf femoral components to treat patients presenting with failed hip arthroplasty involving acetabular bone loss. Retrospective chart review was performed on the practices of three contributing surgeons, with an initial search by item number of the Medicare Benefits Scheme linked to a case list maintained by the manufacturer. An analysis of indications, patient demographics and clinical outcome was performed. The cohort comprised 65.2% female with a median age of 70 years (interquartile range 61–77) and a median follow up of 32.9 months (IQR 13.1 - 49.7). The indications for surgery were infection (12.5%); aseptic loosening (78.1%) and fracture (9.4%), with 65.7% of cases undergoing previous revision hip arthroplasty. A tumour prosthesis was implanted into the proximal femur in 21.9% of cases. Complications were observed in 31.3% of cases, with four cases requiring revision procedures and no deaths reported in this series. Kaplan-Meier analysis of all-cause revision revealed an overall procedure survival of 88.7% at two years (95%confidence interval 69 - 96.2) and 83.8% (95%CI 62 - 93.7) at five years, with pelvic implant-specific survival of 98% (95%CI 86.6 - 99.7) at two and five year follow up. We conclude that an individualised planning approach for custom 3D printed titanium acetabular implants can provide high overall and implant-specific survival at up to five years follow up in complex cases of failed hip arthroplasty and acetabular bone loss.
PVNS or TGCT (Pigmented Villonodular Synovitis, or Tenosynovial Giant Cell tumour) is a benign tumour affecting the synovial lining of joints and tendon sheaths, historically treated with surgical excision or debridement. We have shown previously this management is fraught with high recurrence rates, especially in its diffuse form. We present the encouraging early results of medical management for this condition with use of a CSF1 inhibitor, in comparison to a cohort of 137 cases previously treated at our institution.
Correct prosthetic alignment is important to the longevity and function of a total hip replacement (THR). With the growth of 3-dimensional imaging for planning and assessment of THR, the importance of restoring, not just leg length and medial offset, but anterior offset has been raised. The change in anterior offset will be influenced by femoral anteversion, but there are also other factors that will affect the overall change after THR. Consequently, the aim of this study was to investigate the relationship between anterior offset and stem anteversion to determine the extent to which changing anteversion influences anterior offset. Sixty patients received a preoperative CT scan as part of their routine planning for THR (Optimized Ortho, Sydney). All patients received a Trinity cementless shell and a cemented TaperFit stem (Corin, UK) by the senior author through an anterolateral approach. Stem anteversion was positioned intraoperatively to align with cup anteversion via a modified Ranawat test. Postoperatively, patients received a CT scan which was superimposed onto the pre-op CT scan. The difference between native and achieved stem anteversion was measured, along with the 3-dimensional change in head centre from pre-to post-op. Finally, the relationship between change in stem anteversion and change in anterior offset was investigated.Introduction & aims
Method
The posterior condylar axis of the distal femur is the common reference used to describe femoral anteversion. In the context of Total Hip Arthroplasty (THA), this reference can be used to define the native femoral anteversion, as well as the anteversion of the stem. However, these measurements are fixed to a femoral reference. The authors propose that the functional position of the proximal femur must be considered, as well as the functional relationship between stem and cup (combined anteversion) when considering the clinical implications of stem anteversion. This study investigates the post-operative differences between anatomically-referenced and functionally-referenced stem and combined anteversion in the supine and standing positions. 18 patients undergoing pre-operative analysis with the Trinity OPS® planning (Optimized Ortho, Sydney Australia, a division of Corin, UK) were recruited for post-operative assessment. Anatomic and functional stem anteversion in both the supine and standing positions were determined. The anatomic anteversion was measured from CT and referenced to the posterior condyles. The supine functional anteversion was measured from CT and referenced to the coronal plane. The standing functional anteversion was measured to the coronal plane when standing by performing a 3D/2D registration of the implants to a weight-bearing AP X-ray. Further, functional acetabular anteversion was captured to determine combined functional anteversion in the supine and standing positions.Introduction
Method