Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 124 - 124
1 Jul 2020
Woodmass J Wagner E Borque K Chang M Welp K Warner J
Full Access

Chronic massive irreparable rotator cuff tears represent a treatment challenge and the optimal surgical technique remains controversial. Superior capsular reconstruction (SCR) has been proposed as a means to provide superior stability to the glenohumeral joint, thus facilitating restoration of shoulder function. However, despite the growing use of SCR there is a paucity of data evaluating the outcomes when performed using a dermal allograft. The purpose of this study was to (1) report the overall survival rate (reoperation and clinical failure) of SCR (2) evaluate for pre-operative factors predicting reoperation and clinical failure.

From January 1, 2015 to November 31, 2017, 65 patients were diagnosed with irreparable rotator cuff tears and consented for a superior capsular reconstruction. These surgeries were performed by 6 surgeons, all fellowship trained in either sports or shoulder and elbow fellowships. Outcomes were graded as excellent, satisfactory, or unsatisfactory using the modified Neer scale. An unsatisfactory result was defined as a clinical “failure”. The Kaplan-Meier survival models were created to analyze reoperation-free and failure-free survival for the entire group. The reconstruction was performed using a dermal allograft. There were 31 patients excluded due to insufficient follow-up (< 6 months), leaving 34 included in this study. The mean follow-up was 12 months (range, 6–23). The average number of prior surgeries was 0.91 (range, 0–5), with 52.9% of patients receiving a prior rotator cuff repair and 38.2% of patients with a prior non-rotator cuff arthroscopy procedure.

The one and two-year survival-free of surgery was 64% and 44% and the one and two-year survival free of failure was 34% and 16% following SCR, respectively. For the patients that underwent a reoperation, 62.5% (n= 5/8) underwent reverse shoulder replacements, 25% (n= 2/8) latissimus dorsi tendon transfers, and 12.5% (n= 1/8) a diagnostic arthroscopy. The average period between the primary and revision surgery was 10.2 months (range, 2.1–18.5). All but two patients (75%, n= 6/8) had at least one surgery prior to the SCR. There were 14/34 (41.2%) patients who experienced pain, weakness, and restricted range of motion. These patients were defined as clinical failures with an unsatisfactory grading on Neer's criteria. Previous surgery predicted reoperation (80% vs 43%, p = 0.03). Female gender predicted clinical failure (100% vs 43%, p < 0 .01).

Superior Capsule Reconstruction performed for large to massive rotator cuff tears has a high rate of persistent pain and limited function leading to clinical failure in 65% (n= 22/34) of patients. The rate of failure is increased in revision cases, female gender and increased Goutallier fatty infiltration of the infraspinatus. Narrowed indications are recommended given the surgical complexity and high rate of early failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 456 - 456
1 Dec 2013
Borque K Gold J Ismaily S Patel R Incavo S Noble P
Full Access

Purpose:

Knee pain and instability during high demand activities such as stair descent are reported by patients after TKA. Previous studies theorized that this pain is from increased demand on the quadriceps required to stabilize the femur on the tibia. In this study we explore the relationship between implant design, the posterior cruciate ligament (PCL), and AP stability of the knee during stair descent.

Methods:

CTs of 6 fresh-frozen human cadaveric knees (average age: 61 ± 6.5 years) with functioning cruciates were prepared. All specimens were mounted in a computer controlled, 6 DOF simulator programed to apply physiologic muscle loads and flexion/extension moments simulating the highest demand phase of stair descent (terminal swing to initial contact). A contemporary design of TKA was implanted in each specimen by an experienced surgeon. Testing was repeated after implantation of tibial inserts of the CR, CS with and without a PCL and PS designs.