In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.Aims
Methods
Partial knee arthroplasty (PKA) has demonstrated the potential to improve patient satisfaction over total knee arthroplasty. It is however perceived as a more challenging procedure that requires precise adaptation to the complex mechanics of the knee. A recently developed PKA system aims to address these challenges by anatomical, compartment specific shapes and fine-tuned mechanical instrumentation. We investigated how closely this PKA system replicates the balance and kinematics of the intact knee. Eight post-mortem human knee specimens (age: 55±11 years, BMI: 23±5, 4 male, 4 female) underwent full leg CT scanning and comprehensive robotic (KUKA KR140 comp) assessments of tibiofemoral and patellofemoral kinematics. Specimens were tested in the intact state and after fixed bearing medial PKA. Implantations were performed by two experienced surgeons. Assessments included laxity testing (anterior-posterior: ±100 N, medial-lateral: ±100 N, internal-external: ±3 Nm, varus- valgus: ±12 Nm) under 2 compressive loads (44 N, 500 N) at 7 flexion angles and simulations of level walking, lunge and stair descent based on in-vivo loading profiles. Kinematics were tracked robotically and optically (OptiTrack) and represented by the femoral flexion facet center (FFC) motions. Similarity between intact and operated curves was expressed by the root mean square of deviations (RMSD) along the curves. Group data were summarized by average and standard deviation and compared using the paired Student's T-test (α = 0.05).Introduction
Materials and Methods
Trabecular Titanium is an open-cell regular structure composed by hexagonal cells of controlled pore, manufactured by Electron Beam Melting (EBM) technology, that allows moulding of cellular solid structures. The Lima Delta TT revision cups are One and Revision, which is characterized by a caudal hook and fins. Both allow internal modularity and cranial TT augments. The aim of this prospective study is to evaluate the short to medium-term clinical and radiographic outcomes of acetabular revision cups in TT. Between December 2008 and March 2013 we performed 60 cup revisions, 33 with the Revision cup and 27 with the One cup. The bone defect was classified according to Paprosky acetabular classification: type IIb and IIc presenting continent anterior and posterior acetabular wall were treated by Delta One TT; type IIIa and IIIb were treated with Delta TT Revision. In 20 cases (3.3%) stem revision was associated. Causes of revision were: aseptic loosening in 48 cases, periprosthetic acetabular fractures in 5 cases, recurrent dislocation in 5 cases, infection in 2 cases. In 52 cases bone grafts were used to fill cavitary defects (AIR 1–4). Hemispheric TT augments were used in 13 cases with the same aim. Internal modules were used in 39 cases to restore correct offset. The mean age of patients was 69.6 years (range 29–90). The average follow-up was 39 months (range 19–70).INTRODUCTION
METHODS
Smaller increments in the antero-posterior dimensions of femoral components allows significant improvements in balancing of the knee after TKA with restoration of more normal soft-tissue stability. The soft-tissue stability of the knee after TKA is often compromised by the fact that only a finite set of implantable component sizes is available to match bony anatomy. While this could be overcome with custom components, a more practical solution is a set of femoral components with smaller increments in the antero-posterior (AP) dimension. However, this results in a larger assortment of sizes of both implants and trial components. This study was performed to determine whether smaller increments in the AP sizing of knee prostheses would lead to real benefits in restoration of normal knee function and stability after TKA.Summary:
Introduction:
Engineered bone tissue to recreate the continuity of damaged skeletal segments is one of the field of interest of tissue engineering. Trabecular titanium has very good mechanical properties and high in vitro and in vivo biocompatibility: it can be used in biomedical applications to promote osteointegration demonstrating that it can be successfully used for regenerative medicine in orthopaedic surgery (1). Purpose of this investigation was to evaluate the behavior of adipose tissue derived stem cells (hASCs) cultured on scaffolds of Trabecular TitaniumTM (Lima-Lto) (TT). hASCs are considered to be multipotent mesenchymal stem cells that are easily induced to differentiate into functional osteoblasts both in vitro and in vivo (2). The hASCs were obtained from the subcutaneous adipose tissue of healthy donors during total hip replacement procedures after digestion with collagenase. They were seeded on monolayer and on the TT scaffolds, and incubated at 37 degrees C in 5% CO2 with osteogenic medium or control medium. The expression of bone-related genes using RT-PCR, time course of alkaline phosphatase activity and morphological investigation with Scanning Electron Microscopy (SEM) were performed to evaluate the osteogenic differentiation of hASCs. Alkaline phosphatase activity, marker of the differentiation toward the osteogenic pattern, was significantly higher in hASCs grown with osteogenic medium than in cells grown with control medium, both in monolayer and TT scaffolds; moreover, also alkaline phosphatase of hASCs grown on TT scaffolds in the presence of control medium increased with time, differently from that of cells grown on monolayer. The osteogenic differentiated hASCs expressed the bone-related genes type I collagen, osteocalcin, Runx-2 and alkaline phosphatase. SEM observations showed that hASCs differentiated toward osteoblast-like cells: they produced a big amount of extracellular matrix that covered the surface of the porous scaffolds with bridges between the pore walls. These data suggest that hASCs are able to adhere to TT scaffolds, to acquire an osteoblastic phenotype and to produce abundant extracellular matrix, with but also without osteogenic medium. We can therefore conclude that this material carries osteinductive properties being responsible of ostegenic differentiation; consequently, this scaffold/cells construct is effective to regenerate damaged tissue and to restore the function of bone tissue.
Since 1999 we have adopted the ceramic on ceramic bearing in total hip arthroplasty. We started with sandwich liners, abandoned afterwards in favor of all ceramic liners. We witnessed the progressive evolution of the diameters of the femoral heads from 28 mm to the actual 40 mm. Out of more than 500 implants, we experienced 1 case of fracture of the ceramics, 5 cases of squeaking and 5 dislocations. A total of 5 implants underwent revision.
We performed, from 1999, to March 2009 511 implants in 465 patients (46 bilateral). 320 patients were women, 145 men. Mean follow up is 5.3 years (6 months-10 years). Mean age was 68,4 years (18–80).
We had 5 cases of squeaking: in 1 case it recovered itself, in 2 cases the phenomenon is occasional and in 1 case it’s persistent. No revision surgery has been required by these 4 patients. 1 patient developed squeaking after a subdislocation and needed revision for substitution of the head. We revised 3 other implants: 2 for infection and 1 for a periprosthetic fracture. On the radiological side there were no signs of mobilization of the cup or of the stem. We found radiolucent lines in 35 cases: 13 in zone 1 according to Gruen, 6 in zone 2 and 16 in zone 3. Radiolucent lines were always less than 2 mm wide and stable at all radiographic controls.
The skeleton is tuned for sensing and responding to mechanical forces: a global bone strain moves the extra-cellular fluid through the lacunocanalicular network of compact bone, so gene expression of osteocytes is mechanically modulated by extra cellular fluid flow shear stress. Several studies showed that shear stress modulates bone cells gene expression: in vitro mechanical stimulation impacts the levels of alkaline phosphatase, cAMP, intracellular calcium, NO, prostaglandin E2, c-fos, COX-2, osteopontin and osteocalcin. Aim of this study is to investigate the effect of shear stress on SAOS-2 human osteoblasts proliferation, bone matrix production and mineralization, using a biostable polyurethane as scaffold and a perfusion bioreactor. Polyurethane scaffolds with an average porediameter of 624 micron were utilized. Scaffolds were sterilized and placed in to standard well-plates (condition A) and into a bioreactor with forced perfusion at a rate of 3 ml/min (condition B). Human osteosarcoma cell lineSAOS-2 was obtained from the ATCC and cultured in McCoy’s 5A modified medium. A suspension of 7′105 osteoblasts was added onto the top of each scaffold. Medium was changed every 3 days and sampled for osteopontin and-osteocalcin ELISA kits. After 16 days culture DNA and calcium contents were measured, light microscopy and SEM analysis were performed. In condition B, in comparison to A, we observed 33% higher cells proliferation, 12.6-fold higher osteopontin secretion, 99.6-foldhigher osteocalcin secretion and 8-fold higher calcium deposition. Microscopy observations revealed that in condition A osteoblasts were few with thin discontinuous extracellular matrix; in contrast shear stress induced 3D modeling of cells and matrix organization, so several cells were in multilayer with highly developed matrix and no surfaces were cell free. Statically cultured osteoblasts showed normal proliferation, but a very low matrix synthesis. Into bioreactor, which provides physiological levels of shear stress, the osteoblasts proliferated and showed increased metabolic activity.
For the post-operative evaluation and for the critical comparison of the two groups we’ve considered the following parameters:length of operation,blood loss,ROM(at discharge,at 1 month,at 3 months,at 6 months),functional scores(using the Knee Society Assessment&
Function Score),implants position and postoperative pain.In order to evaluate the differences among the two groups over time,we adopted a general linear model for repeated measures with calculation of Huber White robust standard errors to account for intra-patients correlation over time: a 2 sided p-value<
0.0125 was considered significant and Bonferroni correction was applied for post-hoc test.
The use of conventional stems in hip arthroplasty may be difficult in cases of dysplasia, coxa vara or coxa valga, after fracture or proximal femur osteotomy. In fact the morphologic alterations of the proximal femur might require prosthetic components characterised by small size and different neck angles to restore correct joint biomechanics. In these cases we are often compelled to compromise between the ideal implant aneiversion and fit and what we can really achieve. An alternative to conventional prostheses is represented by custom-made prostheses. For 3 years we have been using the Modulus stem in the treatment of morphologic disorders of the hip. The conic shape of the stem easily fits the different morphologies of the proximal femur, whereas the modularity of the neck makes it possible to correct length, inclination and declination of the femural neck. We studied 59 patients by clinical and radiographic examination before surgery and 1, 3, 6 and 12 months postoperatively. We recorded a statistically significant improvement in the clinical score already at 1 month but this was even better at 6 months after surgery, with respect to the pre-operative examination. With the use of this prosthesis, the recovery of correct joint biomechanics together with high tribologic standards could improve the implant survival, leading to cost reduction and patient satisfaction.