Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 65 - 65
23 Jun 2023
Koller T Reisinger C Beck M
Full Access

To quantify the acetabular coverage of the femoral head, Lequesne's vertical-center-anterior edge (VCA) angle is used on the false profile view. Lateral coverage is determined by Wiberg's lateral-center-edge (LCE) angle on an ap pelvic view. The delimitation of the weightbearing area is defined by the end of the subchondral sclerosis line for both views. To our knowledge the exact anatomic location of the points used for measurement on the acetabular rim are not known.

Six hips from three cadaver pelvises (3 male and 3 female) were investigated. The anterior and lateral points of interested were identified radiographically using fluoroscopy and marked with 1mm ceramic bullets. Standard false profile views and ap pelvic views in neutral inclination and rotation were taken to check the correct location of the ceramic bullets. A CT of each pelvis was made to locate the ceramic bullets and to define the exact anatomic location of the measurement points on the o'clock position. 6 o‘clock was defined as the midpoint between anteroinferior and the posteroinferior rim edges. Values were normalized for a right hip.

The mean clockface location for the VCA was 1:33 (range, 1:15 to 1:40) and for the LCE 0:38 (range, 0:20 to 0:50).

The LCEA is slightly anterior to the 12 o'clock position and remains useful to quantify the lateral coverage. Surprisingly, the point used for measuring the VCA is only about 30° (1h) anterior of the point used for measuring the LCEA. Its value for determining anterior cover has to be questioned. The discrepancy to other studies in the literature is because this study identifies and measures the end of the weight bearing zone, and not the border of the bony acetabulum.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1662 - 1668
1 Nov 2021
Bhanushali A Chimutengwende-Gordon M Beck M Callary SA Costi K Howie DW Solomon LB

Aims

The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements.

Methods

Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1578 - 1584
1 Dec 2019
Batailler C Weidner J Wyatt M Pfluger D Beck M

Aims

A borderline dysplastic hip can behave as either stable or unstable and this makes surgical decision making challenging. While an unstable hip may be best treated by acetabular reorientation, stable hips can be treated arthroscopically. Several imaging parameters can help to identify the appropriate treatment, including the Femoro-Epiphyseal Acetabular Roof (FEAR) index, measured on plain radiographs. The aim of this study was to assess the reliability and the sensitivity of FEAR index on MRI compared with its radiological measurement.

Patients and Methods

The technique of measuring the FEAR index on MRI was defined and its reliability validated. A retrospective study assessed three groups of 20 patients: an unstable group of ‘borderline dysplastic hips’ with lateral centre edge angle (LCEA) less than 25° treated successfully by periacetabular osteotomy; a stable group of ‘borderline dysplastic hips’ with LCEA less than 25° treated successfully by impingement surgery; and an asymptomatic control group with LCEA between 25° and 35°. The following measurements were performed on both standardized radiographs and on MRI: LCEA, acetabular index, femoral anteversion, and FEAR index.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 712 - 719
1 Jun 2018
Batailler C Weidner J Wyatt M Dalmay F Beck M

Aims

The primary aim of this study was to define and quantify three new measurements to indicate the position of the greater trochanter. Secondary aims were to define ‘functional antetorsion’ as it relates to abductor function in populations both with and without torsional abnormality.

Patients and Methods

Three new measurements, functional antetorsion, posterior tilt, and posterior translation of the greater trochanter, were assessed from 61 CT scans of cadaveric femurs, and their reliability determined. These measurements and their relationships were also evaluated in three groups of patients: a control group (n = 22), a ‘high-antetorsion’ group (n = 22) and a ‘low-antetorsion’ group (n = 10).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 6 - 6
1 Jun 2017
Wyatt M Weidner J Pfluger D Beck M
Full Access

The definition of osseous instability in radiographic borderline dysplastic hips is difficult. A reliable radiographic tool that aids decision-making specifically, a tool that might be associated with instability-therefore would be very helpful for this group of patients. The aims of this study were:

(1) To compare a new radiographic measurement, which we call the Femoro-Epiphyseal Acetabular Roof (FEAR) index, with the lateral centre-edge angle (LCEA) and acetabular index (AI), with respect to intra- and interobserver reliability; (2) to correlate AI, neck-shaft angle, LCEA, iliocapsularis volume, femoral antetorsion, and FEAR index with the surgical treatment received instable and unstable borderline dysplastic hips; and (3) to assess whether the FEAR index is associated clinical instability in borderline dysplastic hips.

We defined and validated the FEAR index in 10 standardized radiographs of asymptomatic controls using two blinded independent observers. Interrater and intrarater coefficients were calculated, supplemented by Bland-Altman plots. We compared its reliability with LCEA and AI. We performed a case-control study using standardized radiographs of 39 surgically treated symptomatic borderline radiographically dysplastic hips and 20 age-matched controls with asymptomatic hips (a 2:1 ratio), the latter were patients attending our institution for trauma unrelated to their hips but who had standardized pelvic radiographs between January 1, 2016 and March 1, 2016.

Patient demographics were assessed using univariate Wilcoxon two-sample tests. There was no difference in mean age (overall: 31.5 ± 11.8 years [95% CI, 27.7–35.4 years]; stable borderline group: mean, 32.1± 13.3 years [95%CI, 25.5–38.7 years]; unstable borderline group: mean, 31.1 ± 10.7 years [95% CI, 26.2–35.9 years]; p = 0.96) among study groups. Treatment received was either a periacetabular osteotomy (if the hip was unstable) or, for patients with femoroacetabular impingement, either an open or arthroscopic femoroacetabular impingement procedure. The association of received treatment categories with the variables AI, neck-shaft angle, LCEA, iliocapsularis volume, femoral antetorsion, and FEAR index were evaluated first using Wilcoxon two-sample tests (two-sided) followed by stepwise multiple logistic regression analysis to identify the potential associated variables in a combined setting. Sensitivity, specificity, and receiver operator curves were calculated. The primary endpoint was the association between the FEAR index and instability, which we defined as migration of the femoral head either already visible on conventional radiographs or recentering of the head on AP abduction views, a break of Shenton's line, or the appearance of a crescent-shaped accumulation of gadolinium in the posteroinferior joint space at MR arthrography.

The FEAR index showed excellent intra- and interobserver reliability, superior to the AI and LCEA. The FEAR index was lower in the stable borderline group (mean, −2.1 ± 8.4; 95% CI, −6.3 to 2.0) compared with the unstable borderline group (mean, 13.3 ± 15.2; 95% CI, 6.2–20.4) (p < 0.001) and had the highest association with treatment received. A FEAR index less than 5° had a 79% probability of correctly assigning hips as stable and unstable, respectively (sensitivity 78%; specificity 80%).

A painful hip with a LCEA of 25° or less and FEAR index less than 5° is likely to be stable, and in such a situation, the diagnostic focus might more productively be directed toward femoroacetabular impingement.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 127 - 127
1 Mar 2017
Zurmuehle C Steppacher S Beck M Siebenrock K Zheng G Tannast M
Full Access

Introduction

The limited field of view with less-invasive hip approaches for total hip arthroplasty can make a reliable cup positioning more challenging. The aim of this study was to evaluate the accuracy of cup placement between the traditional transgluteal approach and the anterior approach in a routine setting.

Objectives

We asked if the (1) accuracy, (2) precision, and (3) number of outliers of the prosthetic cup orientation differed between three study groups: the anterior approach in supine position, the anterior approach in lateral decubitus position, and the transgluteal approach in lateral decubitus position.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 34 - 34
1 Nov 2015
Welsh F Helmy N De Gast A Beck M French G Baines J
Full Access

Introduction

Obesity is known to influence surgical risk in total hip replacement (THR), with increased Body Mass Index (BMI) leading to elevated risk of complications and poorer outcome scores. Using a multinational trial data of a single implant, we assess the impact of BMI and regional variations on Harris Hip scores (HHS).

Method

We assessed BMI in 11 regional centres and associations with HHS at one year. Data were collected from 744 patients prospectively from 11 centres in the UK, Germany, Switzerland, Austria, New Zealand and Netherlands as part of a multicentre outcome trial. All Arthroplasties used RM Pressfit vitamys components (Mathys, Switzerland). Demographic, operative data and HHS were analysed with General Linear Model Anova, Minitab 16 (Minitab Inc, Pennsylvania).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 232 - 232
1 Sep 2012
Beck M Kohl S
Full Access

INTRODUCTION

The lifetime of UHMWPE implants may be limited by wear and oxidative degeneration. Wear produced particles are in general biologically active, and may induce osteolysis. As threshold of PE wear rate below which osteolysis is rarely observed is postulated to be less tahn 0.1 mm per year. Moreover, PE delamination and breakage are consequences of the embrittlement of the PE due to oxidation. Both demonstrate, that improving the clinical behaviour of UHMWPE means reduction of wear particles. The first can be achieved by cross-linking the second by the anti-oxidative stabiliser vitamin E. The highly cross-linked PE vitamys ® used for the isoelastic monobloc cup RM Pressfit (Mathys AG Bettlach, Bettlach, Switzerland) is mixed with 0.1% of synthetic vitamin E and is the first and only highly cross-linked PE used in total hip replacement that meets all requirements for the best grade UHMWPE in yield strength, ultimate tensile strength and elongation at break.

METHODS AND MATERIAL

With the first implantation of RM Pressfit vitamys® a prospective multicentre study was started. So far 256 cases in 7 clinics from Europe and New Zealand are included. This report presents the first clinical experiences of one Swiss clinic from the multicentre study. Prospective data collection includes Harris Hip score (HHS), patient satisfaction and radiographic analysis. Clinical and radiographic follow-up is done after 6 weeks, 6, 12 and 24 months, and thereafter for long-term results. Standardized documentation of surgery and postoperative course is performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 223 - 228
1 Feb 2011
Neumann M Nyffeler R Beck M

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck.

In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases.

Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 519 - 519
1 Oct 2010
Howie D Beck M Costi K Ganz R Pannach S Solomon L
Full Access

Introduction: Periacetabular osteotomy is a complex procedure which is associated with significant complications during the learning period and difficult to maintain such expertise when it is undertaken infrequently. Results were reviewed to determine if this difficult PAO procedure can be safely learnt by a process of mentoring and review.

Methods: A structured mentoring program was adopted by the senior author. A double approach was used in the first 11 cases to enhance exposure and minimise the risk of complications. Fifteen osteotomies have subsequently been undertaken using a single approach. The median patient age was 28 years (13–41 years). The median follow-up was 5 years (2–14 years). The clinical and radiographic results were examined.

Results: Two cases in the double approach series progressed to total hip replacement and there were two other major reoperations. Two cases in the single approach series had an ischial non-union not requiring reoperation. The median Harris hip score at latest review was 82 (35–100) and 80 (26–100) for the double and single approach series respectively. All radiographic indices indicated correction of the acetabulum for both series.

Discussion and Conclusion: A structured program of mentoring and review has allowed a complex surgical procedure to be learnt and surgical expertise maintained at a distant centre while avoiding the complications previously associated with the learning curve and achieving the acetabular correction similar to the originator of the procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1317 - 1324
1 Sep 2010
Solomon LB Lee YC Callary SA Beck M Howie DW

We dissected 20 cadaver hips in order to investigate the anatomy and excursion of the trochanteric muscles in relation to the posterior approach for total hip replacement. String models of each muscle were created and their excursion measured while the femur was moved between its anatomical position and the dislocated position. The position of the hip was determined by computer navigation.

In contrast to previous studies which showed a separate insertion of piriformis and obturator internus, our findings indicated that piriformis inserted onto the superior and anterior margins of the greater trochanter through a conjoint tendon with obturator internus, and had connections to gluteus medius posteriorly. Division of these connections allowed lateral mobilisation of gluteus medius with minimal retraction. Analysis of the excursion of these muscles revealed that positioning the thigh for preparation of the femur through this approach elongated piriformis to a maximum of 182%, obturator internus to 185% and obturator externus to 220% of their resting lengths, which are above the thresholds for rupture of these muscles.

Our findings suggested that gluteus medius may be protected from overstretching by release of its connection with the conjoint tendon. In addition, failure to detach piriformis or the obturators during a posterior approach for total hip replacement could potentially produce damage to these muscles because of over-stretching, obturator externus being the most vulnerable.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 63 - 63
1 Mar 2009
Krueger A Kohl S Leunig M Siebenrock K Beck M
Full Access

Purpose: The purpose of this study was to examine the arthroscopy findings in the hips of patient with persistent pain after surgical hip dislocation for femoroacetabular impingement syndrome.

Type of study: Retrospective, consecutive series of patients

Patients and Methods: Sixteen consecutive patients (6 male/10 female; average age 33,5 years 19–60y) with persistent pain after surgical hip dislocation for the treatment of femoroacetabular impingement were included. At the index surgery, all patients had an osteo-chondroplasty of the head neck junction and a resection of the acetabular rim with reattachment of the labrum in 9 cases. All patients had a preoperative arthro-MRI and were treated with arthroscopy of the hip.

Results: At arthroscopy all reattached labra were stable. In the cases without preservation of the labrum, the joint capsule was attached level with the acetabular rim and had important synovitis. All patients had adhesions between the neck of the femur and joint capsule or between labrum and capsule. In 3 patients the arthroscopic procedure was technically limited by massive thickening of the capsule. Overall 75% (12 of 16) patients showed less pain or were pain free. MDA improved from preoperatively 13 to 16 points at last follow up.

Conclusions: Persistent pain after surgical dislocation of the hip could result from intraarticular adhesions that can be shown in the MRI. Hip arthroscopy after previous surgery can be demanding due to scarring. If the adhesions can be released good results can be achieved. Hip arthroscopy is a save therapeutical tool to treat patients with intraarticulary adhesions after surgical dislocation of the hip for femoroacetabular impingement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 64 - 64
1 Mar 2009
Leunig M Mladenov K Jamali A Meyer D Martinez A Beck M Ganz R
Full Access

Background: Acetabular retroversion has been proposed to contribute to the development of osteoarthritis of the hip. For the diagnosis of this condition, conventional AP pelvic radiographs may represent a reliable, easily available diagnostic modality as they can be obtained with a reproducible technique allowing the anterior and posterior acetabular rims to be visible for assessment. This study was designed to

establish a method to directly quantify anatomic acetabular version on AP pelvic radiographs and to

determine the validity of the radiographic “cross-over-sign” to detect acetabular retroversion.

Methods: Using 43 desiccated pelves (86 acetabuli) the anatomic acetabular versions were measured at three different transverse planes (cranially, centrally and caudally). From these pelves, standardized AP pelvic radiographs were obtained. To directly measure central acetabular version (AV), a modified radiographic method is introduced for the use of AP pelvic radiographs. Moreover, the validity of the radiographic “cross-over-sign” to detect cranial acetabular retroversion was determined.

Results: The mean central and caudal anatomic AV were approximately 20°, the mean cranial AV was 8°. Cranial retroversion (AV < 0°) was present in 19 of 86 hips (22%). A linear correlation was found between the central and cranial AV. Below 10° of central AV, all acetabuli were cranially retroverted. Between 10° and 20°, 30% of the acetabuli were cranially retroverted and above 20°, only one of 45 acetabuli was cranially retroverted. The radiographic measurement of the central AV (20.3° ± 6.5) correlated strongly with the anatomic AV (20.1° ± 6.4). The sensitivity of the ‘cross-over-sign’ to detect an cranial acetabular anteversion of less than 4° was 96%, its specificity 95%, and the positive predictive and negative predictive values 90% and 98%, respectively.

Conclusions: The cranial AV is on average 12° lower than the central AV, with the latter directly measurable from AP pelvic radiographs. A central AV of less than 10° was associated with cranial retroversion. The presence of a positive ‘cross-over-sign’ is a highly reliable indicator of cranial AV of < 4°.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 22 - 22
1 Mar 2009
Krueger A Tannast M Kohl S Beck M Siebenrock K
Full Access

Introduction: In the treatment of polytraumatised patients acetabular fractures are challenging because of the necessity of perfect open reduction of the articular surface over an anatomy respecting approach. Luxation of the femoral head with accompanying Pikin fracture, interponated fragments and labral lesions are relevant additional injuries compromising a good result after correct operative treatment. The choice of the approach is a limiting factor for the visualization of the hip joint and is of capital importance for adequate internal fixation. A modified Kocher-Langenbeck- approach with osteotomy of the grater trochanter allows an anatomic reduction under perfect visualization with protection of the soft tissue.

Patients and Methods: This prospective study was accomplished from 1995–2003 including 60 patients (16 female, 16–80years) with an actabulary fracture (posterior wall-, T-type-, and transverse fracture) treated over a modified Kocher-Langenbeck-appraoch with osteotomy of the grater tro-chanter. The included patients had a minimum follow-up of 2 years with clinical and radiological examination. The outcome was assessed with the Merle d’Aubigné-score and degenerative changes with the Tönnis classification.

Results: Within 57 patients an anatomic reduction was achieved. In 3 patients the reduction was not anatomical but satisfactory (1–3mm). Arthrotic changes in the minimujm follow-up of 2 years were observed in 14 patients (8 Ps grade I, 3 Ps grade II, 3 Ps grade III). In 3 patients posttraumatic arthritis had to be treated with THR (1, 3, 8 years postoperatively). A avascular necrosis was not objected.

Conclusion: The treatment of suitable acetabular fractures over a modified Kocher-Langenbeck-approach with a osteotomy of the greater trochanter and dislocation of the femoral head is a safe method for anatomic reduction and internal fixation


Objective: Osteoporotic fractures of the distal forearm are demanding in terms of operative therapy and implants used. Volar fixed angle plating has become a standard procedure for these fractures. Recently intra-medullary nailing was introduced in clinical practice for the use in distal radial fractures. This randomized multi-center study compares both fixation techniques in terms of clinical and radiological outcome as well as quality of life score.

Material and Methods: Up to now a total of 85 patients with extra- and intraarticular unstable fractures of the distal radius were included. 53 patients (Targon DR®, B. Braun-Aesculap: n=24; 2.4 mm plate, Synthes: n=29) completed the 6 months follow-up. Follow up examinations included an osteodensitometry using pQCT, X-ray analysis and a detailed clinical function examination. In addition the SF36 questionaire for quality of life assessment was carried out.

Results: The operation time for volar plating was significantly longer than for intramedullary nailing (50.3±20.2 min versus 40.2±13.4 min), as was the time in hospital (5.4±1.8 days versus 2.2±0.6 days) (MW±SD; p< 0.05; Student-t-Test, post hoc: Bonferonni). The Gartland an Werley function score averaged 2.7±1.1 versus 1.9±0.8 for volar plating in comparision to treatment with the Targon DR® nail and thus just failed to reach statistical significance (p = 0.052). Radiological Evaluation revealed bony healing in all patients of both groups. Radial length was maintained in all but one patient (96%) in the nailing group and all but 2 patients (93%) in the plating group. A loss of volar tilt −5°was seen in 1 patient in the nailing group (4%) and 3 patients in the plating group (10%). Of interest radiological signs of bony healing developed much faster after intramedullary nailing. The Quality of life as measured by the SF36 was minimaly diminished in both groups (body/social function: Targon DR®: 56.3±25.1/63.4±21.2 points − 2.4 mm plate: 52.8±23.3/60.5±23.3 points). Osteoporotic bone loss was detected in a total of 72% of patients. Osteoporosis had no adverse effects on bony healing or functional parameters. We encountered two complications. One mild CRPS (volar plating) and in one case paraesthesia of the R. superficialis n. radialis (intramedullary nailing).

Conclusion: Both intramedullary nailing with the Targon DR® nail and volar plating using a 2.4 mm volar fixed angle plate allows stable fixation of osteoporotic distal forearm fractures. Lower operation time and minimally invasive operative procedure of intramedullary nailing is accompanied by faster mobilization.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 77 - 77
1 Mar 2006
Beck M Leunig M Ganz R
Full Access

Femoroacetabular impingement recently was recognized as cause for osteoarthritis of the hip. There are two mechanism of impingement: (1) cam impingement caused by a non-spherical head, and (2) pincer impingement due to acetabular overcover. We hypothesized that both mechanism result in different articular damage patterns. Of 302 analyzed hips only 26 had an isolated cam and 16 an isolated pincer impingement. Cam impingement caused anterosuperior acetabular cartilage damage with a separation between labrum and cartilage. During flexion the cartilage is sheared off the bone by the non-spherical part of the femoral head. In pincer impingement the cartilage damage was located circumferentially, invovolving only a narrow strip along the acetabular rim. During motion the labrum is crushed between the acetabular rim and the femoral neck causing degeneration and ossification of the labrum.

Cam and pincer impingement are two basic mechanism that lead to osteoarthrosis of the hip. The articular damage pattern differs substantially. Isolated cam or pincer impingement is rare, in most hips a combination is present. Labral damage indicates ongoing impingement and rarely occurs alone.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 10 - 10
1 Mar 2006
Beck M Martinez A Li S Ganz R
Full Access

Radiodense structures resembling ossicles at the acetabular rim have received multiple names including “Os acetabuli, Os supertilii, Os marginale superius acetabuli, and Os coxae quartum”.

Various theories regarding their origin have been postulated. These structures commonly are observed in dysplastic hips and hips suffering from femoro-acetabular impingement and represent fractures of the acetabular rim. In our series we observed acetabular rim fragments in 4.9% of the dysplastic hips and in 6.4% of the hips with femoro-acetabular impingement.

Two different pathomechanics are responsible for the occurrence of these rim fragments. In dysplasia the short acetabular roof reduces the amount of available loading surface which leads to an overload on the lateral margin of the acetabulum, propagating the development of a fatigue fracture. However, as in all hips additional cysts were visible, it must be postulated, that cysts have to be present additionally and act as stress risers through which the rim bone eventually will fail. In hips with femoro-acetabular impingement the mode of failure is different. The relative anterior overcover in retroverted hips is subjected to stress during flexion of the hip, which is further increased by the frequent presence of an non-spheric extension of the femoral head as seen in cam impingement. The nonspheric femoral head-neck junction is jammed into the rim area. By repetitive traumatization the anterior rim eventually will fracture.

The clinical importance of acetabular rim fractures in the dysplastic hip is readily understood even by an unexperienced observer. However, it has to be considered as a sign that the hip has decompensated and it usually goes with significant articular cartilage damage. Because the radiographic appearance of the hip with femoro-acetabular impingement seems normal at first sight, the mechanism leading to anterior rim fracture may be overlooked. However, recognition and adequate treatment is important to prevent further degeneration of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1012 - 1018
1 Jul 2005
Beck M Kalhor M Leunig M Ganz R

Recently, femoroacetabular impingement has been recognised as a cause of early osteoarthritis. There are two mechanisms of impingement: 1) cam impingement caused by a non-spherical head and 2) pincer impingement caused by excessive acetabular cover. We hypothesised that both mechanisms result in different patterns of articular damage. Of 302 analysed hips only 26 had an isolated cam and 16 an isolated pincer impingement. Cam impingement caused damage to the anterosuperior acetabular cartilage with separation between the labrum and cartilage. During flexion, the cartilage was sheared off the bone by the non-spherical femoral head while the labrum remained untouched. In pincer impingement, the cartilage damage was located circumferentially and included only a narrow strip. During movement the labrum is crushed between the acetabular rim and the femoral neck causing degeneration and ossification.

Both cam and pincer impingement lead to osteoarthritis of the hip. Labral damage indicates ongoing impingement and rarely occurs alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 358 - 363
1 Apr 2000
Beck M Sledge JB Gautier E Dora CF Ganz R

In order to investigate the functional anatomy of gluteus minimus we dissected 16 hips in fresh cadavers. The muscle originates from the external aspect of the ilium, between the anterior and inferior gluteal lines, and also at the sciatic notch from the inside of the pelvis where it protects the superior gluteal nerve and artery. It inserts anterosuperiorly into the capsule of the hip and continues to its main insertion on the greater trochanter.

Based on these anatomical findings, a model was developed using plastic bones. A study of its mechanics showed that gluteus minimus acts as a flexor, an abductor and an internal or external rotator, depending on the position of the femur and which part of the muscle is active. It follows that one of its functions is to stabilise the head of the femur in the acetabulum by tightening the capsule and applying pressure on the head. Careful preservation or reattachment of the tendon of gluteus minimus during surgery on the hip is strongly recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 371 - 380
1 May 1994
Gerber C Schneeberger A Beck M Schlegel U

We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Allen suture technique improved the ultimate tensile strength to 359 N for two stitches. Finally, we studied the mechanical properties of several methods of anchorage to bone using typically osteoporotic specimens. Single and even double transosseous sutures and suture anchor fixation both failed at low tensile loads (about 140 N). The use of a 2 mm thick, plate-like augmentation device improved the failure strength to 329 N. The mechanical properties of many current repair techniques are poor and can be greatly improved by using good materials, an improved tendon-grasping suture, and augmentation at the bone attachment.