Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 62 - 62
1 Dec 2022
Bansal R Bourget-Murray J Brunet L Railton P Sharma R Soroceanu A Piroozfar S Smith C Powell J
Full Access

The aim of this study was to determine the incidence, annual trend, perioperative outcomes, and identify risk factors of early-onset (≤ 90 days) deep surgical site infection (SSI) following primary total knee arthroplasty (TKA) for osteoarthritis. Risk factors for early-onset deep SSI were assessed.

We performed a retrospective population-based cohort study using prospectively collected patient-level data from several provincial administrative data repositories between January 2013, and March 2020. The diagnosis of early-onset deep SSI was based on published Centre for Disease Control/National Healthcare Safety Network (CDC/NHSN) definitions. The Mann-Kendall Trend Test was used to detect monotonic trends in early-onset deep SSI rates over time. The effects of various patient and surgical risk factors for early-onset deep SSI were analyzed using multiple logistic regression. Secondary outcomes were 90-day mortality and 90-day readmission.

A total of 20,580 patients underwent primary TKA for osteoarthritis. Forty patients had a confirmed deep SSI within 90-days of surgery representing a cumulative incidence of 0.19%. The annual infection rate did not change over the 7-year study period (p = 0.879). Risk factors associated with early-onset deep SSI included blood transfusions (OR, 3.93 [95% CI 1.34-9.20]; p=0.004), drug or alcohol abuse (OR, 4.91 [95% CI 1.85-10.93]; p<0.001), and surgeon volume less than 30 TKA per year (OR, 4.45 [1.07-12.43]; p=0.013). Early-onset deep SSI was not associated with 90-days mortality (OR, 11.68 [0.09-90-58]; p=0.217), but was associated with an increased chance of 90-day readmission (OR, 50.78 [26.47-102.02]; p<0.001).

This study establishes a reliable baseline infection rate for early-onset deep SSI after TKA for osteoarthritis through the use of a robust methodological process. Several risk factors for early-onset deep SSI are potentially modifiable or can be optimized prior to surgery and be effective in reducing the incidence of early-onset SSI. This could guide the formulation of provincial screening programs and identify patients at high risk for SSI.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 89 - 89
1 Dec 2022
Kitzen J Paulson K Edwards B Bansal R Korley R Duffy P Dodd A Martin R Schneider P
Full Access

Dual plate constructs have become an increasingly common fixation technique for midshaft clavicle fractures and typically involve the use of mini-fragment plates. The goal of this technique is to reduce plate prominence and implant irritation, as these are common reasons for revision surgery. However, limited biomechanical data exist for these lower-profile constructs. The study aim was to compare dual mini-fragment orthogonal plating to traditional small-fragment clavicle plates for biomechanical non-inferiority and to determine if an optimal plate configuration could be identified, using a cadaveric model.

Twenty-four cadaveric clavicles were randomized to one of six groups (n=4 per group), stratified by CT-based bone mineral content (BMC). The six different plating configurations compared were: pre-contoured superior or anterior fixation using a single 3.5-mm LC-DC plate, and four different dual-plating constructs utilizing 2.4-mm and 2.7-mm reconstruction or LC-DC plates. The clavicles were plated and then osteotomized to create an inferior butterfly fracture, which was then fixed with a single interfragmentary screw (OTA 15.2B). Axial, torsional, and bending (anterior and superior surface loading) stiffness were determined for each construct through non-destructive cyclic testing, using an MTS 858 Bionix materials testing system. This was followed by a load-to-failure test in three-point superior-surface bending. Kruskal-Wallace H and Mann-Whitney U were used to test for statistical significance.

There were no significant differences in BMC (median 7.9 g, range 4.2-13.8 g) for the six groups (p=1.000). For axial stiffness, the two dual-plate constructs with a superior 2.4-mm and anterior 2.7-mm plate (either reconstruction or LC-DC) were significantly stiffer than the other four constructs (p=0.021). For both superior and anterior bending, the superior 2.4-mm and anterior 2.7-mm plate constructs were significantly stiffer when compared to the 3.5-mm superior plate (p=0.043). In addition, a 3.5-mm plate placed anterior was a stiffer construct than a superior 3.5-mm plate (p=0.043). No significant differences were found in torsional stiffness or load-to-failure between the different constructs.

Dual plating using mini-fragment plates is biomechanically superior for fixation of midshaft clavicle fractures when compared to a single superior 3.5-mm plate and has similar biomechanical properties to a 3.5-mm plate placed anteriorly. With the exception of axial stiffness, no significant differences were found when different dual plating constructs were compared to each other. However, placing a 2.4-mm plate superiorly in combination with a 2.7-mm plate anteriorly might be the optimal construct, given the biomechanical superiority over the 3.5-mm plate placed superior.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 68 - 68
1 Feb 2012
Bansal R Bouwman N Hardy S
Full Access

Background

One of the prime concerns when managing patients in plaster casts is loss of reduction. There have been studies showing that proper moulding of the plaster cast is critical in maintaining reduction. Recent studies have negated concerns that fibreglass (FG) casts do not allow swelling, when compared to plaster of Paris (POP) casts. However, their potential in maintenance of reduction has not been investigated.

Materials and methods

We compared the three-point bending properties of FG casts with POP casts over the first 48 hours. The effect of splitting the casts, at one hour and 24 hours, was studied. Three identical jigs with hinged metal rods were designed to simulate a Colles fracture. The bending force was provided by 0.5 kg weight applied at one end of the jig. The resultant displacement was measured to nearest 0.01 mm over the next 48 hours. Each test was repeated 6 times (total 6 groups and 36 tests).