Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Full Access

To date, few studies have investigated the feasibility of the loop-mediated isothermal amplification (LAMP) assay for identifying pathogens in tissue samples. This study aimed to investigate the feasibility of LAMP for the rapid detection of methicillin-susceptible or methicillin-resistant Staphylococcus aureus (MSSA or MRSA) in tissue samples, using a bead-beating DNA extraction method. Twenty tissue samples infected with either MSSA (n = 10) or MRSA (n = 10) were obtained from patients who underwent orthopedic surgery for suspected musculoskeletal infection between December 2019 and September 2020. DNA was extracted from the infected tissue samples using the bead-beating method. A multiplex LAMP assay was conducted to identify MSSA and MRSA infections. To recognize the Staphylococcus genus, S. aureus, and methicillin resistance, 3 sets of 6 primers for the 16S ribosomal ribonucleic acid (rRNA) and the femA and mecA genes were used, respectively. The limit of detection and sensitivity (detection rate) of the LAMP assay for diagnosing MSSA and MRSA infection were analyzed. The results of this study suggest that the LAMP assay performed with tissue DNA samples can be a useful diagnostic method for the rapid detection of musculoskeletal infections caused by MSSA and MRSA.


Purpose

We aimed to investigate whether the anterior superior iliac spine could provide consistent rotational landmark of the tibial component during mobile-bearing medial unicompartmental knee arthroplasty (UKA) using computed tomography (CT).

Methods

During sagittal tibial resection, we utilized the ASIS as a rotational landmark. In 47 knees that underwent postoperative CT scans after medial UKA, the tibial component position was assessed by drawing a line tangential to the lateral wall of the tibial component. Rotation of the tibial component was measured using two reference lines: a line perpendicular to the posterior cortical rim of the tibia (angle α) and Akagi's line (angle β). Instant bearing position and posterior cruciate ligament fossa involvement were also evaluated. External rotation of the tibial component relative to each reference line and external rotation of the bearing relative to the lateral wall of the tibial component were considered positive values.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1071 - 1076
1 Aug 2012
Lim H Bae J Song S Kim S

Medium-term survivorship of the Oxford phase 3 unicompartmental knee replacement (UKR) has not yet been established in an Asian population. We prospectively evaluated the outcome of 400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at the time of operation of 69 years (48 to 82). The mean follow-up was 5.2 years (1 to 10). Clinical and radiological assessment was carried out pre- and post-operatively. At five years, the mean Knee Society knee and functional scores had increased significantly from 56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively. The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival rate was 94% (95% confidence interval 90.1 to 98.0). A total of 14 UKRs (3.5%) required revision. The most common reason for revision was dislocation of the bearing in 12 (3%). Conversion to a total knee replacement was required in two patients who developed osteoarthritis of the lateral compartment.

This is the largest published series of UKR in Korean patients. It shows that the mid-term results after a minimally invasive Oxford phase 3 UKR can yield satisfactory clinical and functional results in this group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 185 - 189
1 Feb 2012
Lim H Bae J Park Y Park Y Park J Park J Suh D

The purpose of this study was to evaluate the long-term functional and radiological outcomes of arthroscopic removal of unstable osteochondral lesions with subchondral drilling in the lateral femoral condyle. We reviewed the outcome of 23 patients (28 knees) with stage III or IV osteochondritis dissecans lesions of the lateral femoral condyle at a mean follow-up of 14 years (10 to 19). The functional clinical outcomes were assessed using the Lysholm score, which improved from a mean of 38.1 (sd 3.5) pre-operatively to a mean of 87.3 (sd 5.4) at the most recent review (p = 0.034), and the Tegner activity score, which improved from a pre-operative median of 2 (0 to 3) to a median of 5 (3 to 7) at final follow-up (p = 0.021). The radiological degenerative changes were evaluated according to Tapper and Hoover’s classification and when compared with the pre-operative findings, one knee had grade 1, 22 knees had grade 2 and five knees had grade 3 degenerative changes. The overall outcomes were assessed using Hughston’s rating scale, where 19 knees were rated as good, four as fair and five as poor.

We found radiological evidence of degenerative changes in the third or fourth decade of life at a mean of 14 years after arthroscopic excision of the loose body and subchondral drilling for an unstable osteochondral lesion of the lateral femoral condyle. Clinical and functional results were more satisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 120 - 125
1 Jan 2011
Lim H Bae J Song H Teoh SH Kim H Kum D

Medial open-wedge high tibial osteotomy has been gaining popularity in recent years, but adequate supporting material is required in the osteotomy gap for early weight-bearing and rapid union. The purpose of this study was to investigate whether the implantation of a polycaprolactone-tricalcium phosphate composite scaffold wedge would enhance healing of the osteotomy in a micro pig model. We carried out open-wedge high tibial osteotomies in 12 micro pigs aged from 12 to 16 months. A scaffold wedge was inserted into six of the osteotomies while the other six were left open. Bone healing was evaluated after three and six months using plain radiographs, CT scans, measurement of the bone mineral density and histological examination.

Complete bone union was obtained at six months in both groups. There was no collapse at the osteotomy site, loss of correction or failure of fixation in either group. Staining with haematoxylin and eosin demonstrated that there was infiltration of new bone tissue into the macropores and along the periphery of the implanted scaffold in the scaffold group. The CT scans and measurement of the bone mineral density showed that at six months specimens in the scaffold group had a higher bone mineral density than in the control group, although the implantation of the polycaprolactone-tricalcium phosphate composite scaffold wedge did not enhance healing of the osteotomy.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 117 - 117
1 Mar 2010
Lim H Bae J Cho J Lee J Song S
Full Access

Spontaneous osteonecrosis of the knee (SONK) is a distinct clinical condition occurring in patients without any associated risk factors. There is controversy as to the best method of treatment, and the available literature would suggest that patients with SONK have a worse outcome. We evaluated the clinical and radiographic outcomes of unicompartmental knee arthroplasty using Oxford prosthesis in patients with spontaneous osteonecrosis

Between September 2002 and March 2008, 20 knees (18 patients) with SONK were treated with Oxford unicompartmental knee arthroplasty. There were fifteen women and three men with a mean age of 61.1 years old. The mean follow up was 37 months. The clinical assessment was performed using the American knee society score rating system. The preoperative radiography and MRI were analyzed according to size and stage of the osteonecrotic lesion and the osteoarthritic changes. Postoperatively, new osteonecrotic lesion, loosening of implant, subsidence, arthritic changes of other compartment were recorded.

The mean preoperative knee score and the knee function score were 52.5 and 56.0 points, respectively. The knee score was improved to 89.2 points (p < 0.05) and the knee function score was also improved to 85.2 points (p < 0.05) at last follow up. There were no implant failures. There was no new necrotic lesion in the lateral compartment, loosening, subsidence and arthritic change.

The Oxford Unicompartmental knee arthroplasty for spontaneous osteonecrosis of the knee provided satisfactory clinical and radiological results in a short to medium term. However, a longer term follow up will be needed.