Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 537 - 537
1 Aug 2008
Chandran P Mereddy PKR Azzabi M Andrews M Bradley JG
Full Access

Aim: To compare the difference in periprosthetic bone density between cemented and uncemented total hip replacement at a minimum follow up of 10 years.

Patients and methods: We looked at a cohort of 17 patients who have had bilateral total hip replacement with cemented Charnley total hip on one side and uncemented Furlong total hip on the other side between 1984 and 1994 (minimum follow up 10 years). Harris and Oxford hip scores were used to determine the function, SF 36 was used to measure quality of life and Dual energy X-Ray absorptiometry (DEXA) scan was used to quantify bone mineral density adjacent to the prosthesis. The results from the DEXA scan for cemented and the uncemented hips were analysed using Paired samples two tailed t-tests. To compare the Harris hip scores, a non-parametric Wilcoxon test was used. Pearson correlations were carried out to examine the relationship between the bone density measures (averaged for each zone) and the quality of life measures.

Results: Bone mineral density was higher on the Furlong side in Gruen Zones 2, 3, 5 and 6 of the proximal femur and DeLee Charnley Zone 1 of the acetabulum. In all other zones there was no statistical difference. Comparison of Harris hip scores and Oxford hip scores showed no statistically significant difference between the two hips (p = 0.108). Age is negatively correlated with bone density in Gruen zones 6 and 7 and acetabular zones 2 and 3.

Conclusion: Bone density is better preserved around the uncemented HAC coated stem compared to the Charnley cemented stem.