An increasingly used treatment for end-stage ankle osteoarthritis is total ankle replacement (TAR). However, implant loosening and subsidence are commonly reported complications, leading to relatively high TAR failure rates. Malalignment of the TAR has often been postulated as the main reason for the high incidence of these complications. It remains unclear to what extent malalignment of the TAR affects the stresses at the bone-implant interface. Therefore, this study aims to elucidate the effect of TAR malalignment on the contact stresses on the bone-implant interface, thereby gaining more understanding of the potential role of malalignment in TAR failure. FE models of the neutrally aligned as well as malaligned CCI Evolution TAR implant (Van Straten Medical) were developed. Separate models were developed for the tibial and talar segment, with the TAR components in neutral alignment and 5° and 10° varus, valgus, anterior and posterior malalignment, resulting in a total of 9 differently aligned TAR models. Loading conditions of the terminal stance phase of the gait cycle, when the force on the ankle joint is highest (5.2x body weight), were applied. Peak and mean contact pressure and shear stress at the bone-implant interface were analyzed. Also, stress distributions on the bone-implant interface were visualized. In the neutrally aligned tibial and talar TAR models, peak contact pressures of respectively 98.4 MPa and 68.2 MPa, and shear stresses of respectively 49.3 MPa and 39.0 MPa were found. TAR malalignment increases peak contact pressure and shear stress on the bone-implant interface. A maximum peak contact pressure of 177 MPa was found for the 10° valgus malaligned tibial component and the highest shear stress found was 98.5 MPa for the 10° posterior malaligned talar model. Upon TAR malalignment contact stresses increase substantially, suggesting that proper orientation of the TAR is needed to minimize peak stresses on the bone-implant interface. This is in line with previous studies, which state that malalignment considerably increases bone strains, micromotion, and internal TAR contact pressures, which might increase the risk of TAR failure. Further research is needed to investigate the relationship between increased contact stresses at the bone-implant interface and TAR failure.
Malalignment is often postulated as the main reason for the high failure rate of total ankle replacements (TARs). Only a few studies have been performed to correlate radiographic TAR malalignment to the clinical outcome, but no consistent trends between TAR alignment parameters and the clinical outcome were found. No standard TAR alignment measurement method is present, so reliable comparison between studies is difficult. Standardizing TAR alignment measurements and increasing measurable parameters on radiographs in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurement on radiographs in the clinic. A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed and used by two observers to measure TAR alignment parameters of ten patients. The Intraclass Coefficient (ICC) was calculated and accuracy was compared to the manual measurement method commonly used in the clinic. The tool showed an accuracy of 76% compared to 71% for the method used during follow-up in the clinic. ICC values were 0.94 (p<0.01) and higher for both inter-and intra-observer reliability. The tool presents an accurate, consistent, and reliable method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to any TAR design, it offers a valuable addition in the clinic and for research purposes.
Complications after spinal fusion surgery are common, with implant loosening occurring in up to 50% of osteoporotic patients. Pedicle screw fixation strength reduces as a result of decreased trabecular bone density, whereas sublaminar wiring is less affected by these changes. Therefore, pedicle screw augmentation with radiopaque sublaminar wires (made with Dyneema Purity® Radiapque fibers, DSM Biomedical, Geleen, the Netherlands) may improve fixation strength. Furthermore, sublaminar tape could result in a gradual motion transition to distribute stress over multiple levels and thereby reduce implant loosening. The objective of this study is to test this hypothesis in a novel experimental setup in which a cantilever bending moment is applied to individual human vertebrae. Thirty-eight human cadaver vertebrae were stratified into four different groups: ultra-high molecular weight polyethylene sublaminar tape (ST), pedicle screw (PS), metal sublaminar wire (SW) and pedicle screw reinforced with sublaminar tape (PS+ST). The vertebrae were individually embedded in resin, and a cantilever bending moment was applied bilaterally through the spinal rods using a universal material testing machine. This cantilever bending setup closely resembles the loading of fixators at transitional levels of spinal instrumentation. The pull-out strength of the ST (3563 ± 476N) was not significantly different compared to PS, SW or PS+ST. The PS+ST group had a significantly higher pull-out strength (4522 ± 826N) compared to PS (2678 ± 292N) as well as SW (2931 ± 250N). The higher failure strength of PS + ST compared to PS indicates that PS augmentation with ST may be an effective measure to reduce the incidence of screw pullout, even in osteoporotic vertebrae. Moreover, the lower stiffness of sublaminar fixation techniques and the absence of damage to the cortices in the ST group suggest that ST as a stand-alone fixation technique in adult spinal deformity surgery may also be clinically feasible and offer clinical benefits.
Novel biomaterials are being developed and studied, intended to be applied as bone graft substitute materials. Typically, these materials are being tested in in vitro setups, where among others their cytotoxicity and alkaline phosphatase activity (as a marker for osteoblastic differentiation) are being evaluated. However, it has been reported that in vitro tests correlate poorly with in vivo results and therefore many promising biomaterials may not reach the clinic as a bone graft substitute product. One of the reasons for the poor correlation, may be the minimal complexity of the in vitro tests, as compared to the in vivo environment. Ex vivo models, mimicking the natural tissue environment whilst maintaining control of culture parameters, may be a promising alternative to assess biomaterials for bone formation. Assess the possibility of an ex vivo culture platform to test biomaterials on their potential to stimulate new bone formation. Osteochondral plugs (cylinders n=10, Ø 10 mm, height 15 mm) were drilled from fresh porcine knees, from the slaughterhouse. A bone defect (Ø 6 mm) was created and which was filled with a biomaterial graft (S53P4 bioactive glass (n=3); collagen sponges loaded with BMP-2 (n=3, as positive control)) or kept empty (n=4). The explants were cultured in custom-made two-chamber bioreactors for six weeks (LifeTec Group BV). Cartilage and bone were physically separated, similar to the in vivo situation, by a sealing ring. The two tissues were cultured in separate compartments, allowing for specific culture medium for each tissue. Medium was changed every 2–3 days and weekly micro computed tomography (µCT) images were obtained to longitudinally monitor the formation of new bone. An MTT assay was performed on half of the samples after six weeks of culture. The other samples were fixed for histology, to determine which cells were present after six weeks. The MTT metabolic assay showed that a number of cells in the bone were viable after six weeks. The further away from the border, the fewer living cells were observed. The cells in the cartilage also survived. No significant bone formation was observed with µCT in either of groups, even though abundant bone formation was expected in the BMP-2 group. Explanations of the negative results of the positive group might be that too few viable cells remain after six weeks, or that the cells that are still present are not able to form bone. No significant bone formation was observed in the bone defects in osteochondral explants that were cultured with, or without, biomaterials for six weeks. However, the platform showed that it is capable to successfully culture osteochondral explants for six weeks. Histology needs to be performed to evaluate which cells were present at the end of the culture and this will be compared to the cells present directly after drilling the explants.
Growth-guidance constructs are an alternative to growing rods for the surgical treatment of early onset scoliosis (EOS). In growth-guidance systems, free-sliding anchors preserve longitudinal spinal growth, thereby eliminating the need for surgical lengthening procedures. Non-segmental constructs containing ultra-high molecular weight polyethylene (UHMWPE) sublaminar wires have been proposed as an improvement to the traditional Luque trolley. In such a construct, UHMWPE sublaminar wires, secured by means of a knot, serve as sliding anchors at the proximal and distal ends of a construct, while pedicle screws at the apex prevent rod migration and enable curve derotation. Ideally, a construct with the optimal UHMWPE sublaminar wire density, offering the best balance between providing adequate spinal fixation and minimizing surgical exposure, is designed preoperatively for each individual patient. In a previous study, we developed a parametric finite element (FE) model that potentially enables preoperative patient-specific planning of this type of spinal surgery. The objective of this study is to investigate if this model can capture the decrease in range of motion (ROM) after spinal fixation as measured in an experimental study. In a previous INTRODUCTION
MATERIALS AND METHODS
Bio-Active Glass (BAG) is a promising bone graft substitute for large bone defect reconstruction because of its favourable osteoconductive, antibacterial and angiogenic properties. Potentially, it could also mechanically reinforce the defect, thus making it suitable for load-bearing defects. However, the mechanical properties of the reconstructive layer consisting of BAG/bone allograft mixtures are unknown. The goals of this study therefore were, first, to measure the mechanical properties of different BAG/bone graft mixtures and, second, to investigate to what extent such mixtures could reinforce distal tibial defects using micro-FE analysis and high-resolution CT scans. Four different BAG/bone graft mixtures were impacted in a cylindrical holder, mechanically tested in confined compression and scanned with micro-CT. From these images, bone graft material and glass were segmented using two different threshold values. The interface between bone and BAG was modelled separately by dilating the glass phase. Micro-Finite-Element (FE) models of the composites were made using a Young's modulus of 2.5 GPa for bone and 35 GPa for BAG. The Young's modulus for the interface region was determined by fitting experimental and micro-FE results for the same specimens. (82 μm resolution) CT scans of a 9 mm region of the distal tibia of 3 subjects were used. Micro-FE models of this region were made to determine its stiffness in the original state, with a simulated cortical defect and after a mixture of BAG/bone was modelled in the defect.Background
Materials and Methods
Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant. In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score.Background
Methods
Finite element (FE) models have become a standard pre-clinical tool to study biomechanics of spine and are used to simulate and evaluate different strategies in scoliosis treatment: examine their efficacy as well as the effect of different implant design parameters. The goal of this study is to investigate, in a system of rods and laminar wires, the effect of the number of wires and their pre-stress on whole spine stiffness. A generic FE model was developed to represent a full human spine, including vertebrae, intervertebral discs, ligaments, facet and costovertebral joints, and ribcage. Intervertebral discs were modeled with 3D rebar elements with linear elastic material properties. Vertebrae, ribs, sternum, facet joints, cartilage and endplates were modeled with brick elements, and costal muscles with shell elements with linear elastic properties. Furthermore, ligaments were modeled with truss elements with nonlinear hypo-elastic properties. The spine model was instrumented from T7 to T12 with rods and wires modeled as titanium. Nonlinear contact properties were defined for rib neck-vertebra, transverse processes-rib and facet joint sets. The FE model was loaded in flexion and the whole spine instantaneous stiffness was calculated for different wire pre-stressing levels (0.1 to 2 MPa). Similar analyses were performed with changed numbers of wires and whole spine stiffness was calculated.Background
Methods
Chronic osteomyelitis is historically treated in a two stage fashion with antibiotic-loaded polymethylmethacrylate (PMMA) as local antibacterial therapy. However, two-stage surgeries are associated with high morbidity, long hospitalization and high treatment costs. In recent years new biomaterials were developed that allow to change this treatment algorithm. S53P4 bioactive glass is such a novel biodegradable antibacterial bone graft substitute that enables a one-stage surgery in local treatment of chronic osteomyelitis. This study aimed to explore the eradication of infection and bone healing capacities of S53P4 bioactive glass in clinical practice. In this prospective longitudinal outcome study, clinical applicability of S53P4 bioactive glass in treatment of patients with chronic osteomyelitis was assessed. All patients with clinically, haematologically and radiologically evident chronic osteomyelitis were included. All patients were treated with an extensive debridement surgery, S53P4 bioactive glass implantation and systemic antibiotic administration. Primary endpoint of this study is eradication of infection. During follow-up eradication was analysed based on clinical outcomes, blood samples (inflammatory parameters) and radiological outcomes. The secondary endpoint, bone healing, is assessed using conventional radiographic images of the treated region. Between 2011 and 2016, 25 patients were included in this study, with a mean follow-up of 23 months (range 4 – 57). Hospital stay was short with a mean of 18 days (range 4 – 40) and patients required an average of 1,4 surgeries (range 1 – 4). The inflammatory parameter C-reactive protein (CRP) showed a normalization after a mean duration of 46 days (range 0 – 211). At the end of follow-up haematological and clinical outcomes showed eradication of infection in 24 (96%) of all patients. Radiologically none of all patients showed persisting signs of infection and bone healing was observed in 22 (88%) patients based on changes on conventional radiographic images. One patient had a persistent infection without any bone healing, this patient had an infected non-union prior to surgery. There were two other patients with an initial infected non-union fracture which was not consolidated at last follow-up, although they had successful infection treatment. Another patient had a femoral fracture after surgery that needed additional surgery which did not interfere with eradication of infection. Four (16%) of all patients had initial wound healing problems related to compromised skin and/or soft tissue prior to surgery. Based on the results of our clinical experience, S53P4 bioactive glass can successfully be used in a one-stage procedure for treatment of chronic osteomyelitis. Eradication of infection was successful in almost all patients and so far no patients required a second surgery due to infection recurrence. Bone healing (incorporation of the bioactive glass) was seen in all patients except for the patients with an initial infected non-union fracture. As a consequence of these results, we changed our institutional protocol for treatment of chronic osteomyelitis to a one-stage approach instead of a two-step approach.
Total ankle replacement (TAR) is increasingly used in the treatment of end-stage ankle arthropathy, but much debate exists about the clinical result. The goals of present study are: 1) to provide an overview of the clinical outcome of 58 TAR's in a single centre and 2) to assess the association between radiological characteristics and clinical outcome. We reviewed a prospective included cohort of 58 TAR's in 54 patients with a mean age of 66.9 (range 54–82) and a mean follow-up of 21.6 months (range 1.45–66.0). The TAR's where performed by a single surgeon in a single centre (MUMC) between 2010 and 2015, using the CCI ankle replacement. A standard surgical protocol and standardized post-op rehabilitation was used. Patients were followed-up pre-op and at 1 day, 6 weeks, 3–6–12 months and yearly thereafter post-op. The AOFAS and range of motion (ROM) were assessed and all complications, re-operations and the presence of pain were recorded. Radiographic assessment consisted of the estimation of prosthesis alignment, migration, translation and radiolucent lines using the Rippstein protocol (1). The clinical outcome was compared with a systematic review of TAR outcome. Ten intra-operative complications occurred and 9 were malleolar fractures. Post-operative complications occurred in 20 out of the 54 patients (37.0%). Impingement (5/54 patients), deep infection (4/54 patients), delayed wound healing (3/54 patients) and minor nerve injuries (3/54 patients) were the most frequently recorded. 18 patients (31.0%) underwent one or more re-operations and 12 of these 18 patients underwent a component revision (mostly the PE insert) or a conversion to arthrodesis. Despite the complications and revisions, the functional outcome improved. Radiologically 15.8% of the TAR's were positioned in varus and 1.8% in valgus. Migration in the frontal and sagittal plane is seen in 3 and 2 TAR's respectively. Radiolucency is significantly increasing with the follow-up time (p=0.009). Migration in the frontal plane is significantly associated with conversion to arthrodesis (p=0.005) and migration in the sagittal plane to revision of a component or conversion to arthrodesis (p=0.04). Finally, pain is significantly associated with re-operations (p=0.023) and complications (p=0.026). Remarkable is that the clinical outcome is independent of the direct post-op alignment of the TAR. The complication-, re-operation and revision or conversion to arthrodesis rates makes the clinical outcome of TAR still questionable favourable. Especially the complication and re-operation incidences are greater than found in the systematic review. However, it is remarkable that the minor complications and re-operations not related to the TAR are not often mentioned in the literature. Radiographic characteristics could be of value in predicting this clinical outcome and thereby influence the post-operative handling. In conclusion, our results show relatively high incidences of complications (37.0%) and re-operations (31.0%) when minor complications and re-operations are included. TAR clinical outcome can be predicted by radiographic migration characteristics and pain.