Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 298 - 298
1 Jul 2011
Langton D Jameson S Joyce T Ramasetty N Natu S Antoni N
Full Access

In our independent centre, from 2002 to 2009, 155 BHRs (mean F/U 60 months) have been implanted as well as 420 ASR resurfacings and 75 THRs using ASR XL heads on SROM stems (mean F/U 35)

During this period we have experienced a number of failures with patients complaining of worsening groin pain at varying lengths of time post operatively. Aspiration of the hip joints yielded a large sterile effusion on each occasion. At revision, there were copious amounts of green grey fluid with varying degrees of necrosis. There were 17 failures of this nature in patients with ASR implants (12 females) and 0 in the BHR group. This amounts to a failure of 3.5% in the ASR group.

Tissue specimens from revision surgery showed varying degrees of “ALVAL” as well as consistently high numbers of histiocytes. Particulate metal debris was also a common finding.

The mean femoral size and acetabular anteversion and inclination angles of the ARMeD group/all asymptomatic patients was 45/49mm (p< 0.001), 27/20°(p< 0.001) and 53/48°(p< 0.08). Median blood chromium(Cr) and cobalt(Co) was 29 and 69 μg/L respectively in the ARMeD group versus 3.9 and 2.7 μg/L in the asymptomatic patients (n=160 with ion levels). Explant analysis confirmed greater rates of wear than expected.

Lymphocyte proliferation studies involving ARMeD patients showed no hyper reactivity to Cr and Co in vitro implying that these adverse clinical developments are mediated by a toxic reaction or a localised immune response.

Our overall results suggest that the reduced arc of cover of the fourth generation ASR cup has led to an increased failure rate secondary to the increased generation of metal debris. This failure rate is 7% in ASR devices with femoral components _47mm.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 95 - 95
1 May 2011
Alshryda S Sharda P Shetty A Vaghela M Logishetty R Tulloch C Antoni N Mason J
Full Access

Introduction: Today’s aging population has resulted in an increase in the number of major orthopaedic surgical interventions in the elderly. Total knee replacement (TKR) is one of the commonest operations in orthopaedic practice. The fourth annual report of the National Joint Registry showed that there were 60 986 TKR performed in England and Wales in 2006. The true figure is probably much higher. Literature showed that 20–70% of patients who had TKR needed 1–3 units of blood.

Although safer than ever, allogeneic transfusion is still associated with risks for the recipient (haemolysis, infection, immunosuppression, transfusion-related acute lung injury and even death).

Tranexamic acid (TA) is a synthetic antifibrinolytic agent that has been successfully used to stop bleeding after dental operation, removal of tonsils, prostate surgery, heavy menstrual bleeding, eye injuries and in patients with Haemophilia.

In this study Tranexamic acid was applied topically to the exposed tissue around the knee joint prior to the wound closure and tourniquet release. It is anticipated that this method of administration is quick, easy, associated with less systemic side effect. Also, it provides a higher concentration of the Tranexamic acid at the bleeding site.

Objectives: To find out whether Tranexamic acid can reduce blood loss and subsequent blood transfusion significantly after total knee replacement when applied topically without extra side effects.

Design: A double blind randomised controlled trial of 150 patients who underwent unilateral primary cemented total knee replacement. This number gives a 90% power to detect a 50% reduction in blood loss and 80% power to detect a reduction in blood transfusion from current local standard 30% to 10%.

Outcome Measures: Blood loss, transfusion, Length of stay, complications, Euroqol and Oxford Knee Score.

Results: The two groups were comparable in age, weight, height, BMI, Tourniquet time, and type of anaesthesia. There has been significant differences in the amount of blood loss and blood transfusion in favour of tranexamic acid (p-values are 0.001 and 0.007 respectively). Fourteen patients needed blood transfusion ranged from 2–6 units. Thirteen were in the Placebo group and only one in the Tranexamic acid. There has been no significant difference among other outcomes in particular complications rates such as DVT and pulmonary embolism.