Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 52 - 52
1 Jan 2004
Mazel C Marmorat J William J Antonetti P Terracher R Guingand O de Thomasson E
Full Access

Purpose: We analysed retrospectively 32 cases of posterior cervicothoracic fixation for spinal tumours. We evaluated spinal stability, spinal alignment, and associated complications.

Material and methods: Thirty-two patients underwent surgery: 27 men and five women, mean age 52 years, age range 17–72 years. We implanted 96 articular screws in C4 to C6, 54 screws in C7 and 180 pedicular screws in T1 to T8. Nineteen patients had primary lung cancer with spinal invasion, eleven had spinal metastases, one had a chondrosarcoma and one had a myeloma. For the first group of 19 patients, en bloc resection of the tumour with the vertebra was performed: four total vertebrectomies, 15 partial vertebrectomies. In a second group of 15 patients, palliative posterior fixation was performed with laminectomy decompression.

Results: Follow-up ranged from three to 54 months with a mean of 15 months. Mean survival after total or partial vertebrectomy was 16 months (range 3 – 54 months). Survival after palliative decompression was eleven months with a range from five to 19 months. There were no changes in the sagittal alignment in 30 patients: two patients developed mechanical complications late after surgery requiring revision. We did not have any case of screw, plate or rod fracture. There were no neurological complications related to screw insertion either at the thoracic level (180 screws) or the cervical level (96 screws in C4C5C6 and 54 screws in C7). A control scan was available for 21 patients and revealed a malposition of the implanted screws for 2.5% of the screws with no clinical impact.

Discussion: Posterior screw fixation is a good method to stabilise the cervicothoracic spine during tumour surgery. Articular cervical screws and transpedicular thoracic screws provide effective stability postoperatively. In addition, this type of instrumentation does not interfere should subsequent laminectomy or wider resection be necessary.