Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Bone & Joint Research
Vol. 2, Issue 9 | Pages 200 - 205
1 Sep 2013
Amarasekera HW Campbell PC Parsons N Achten J Masters J Griffin DR Costa ML

Objectives

We aimed to determine the effect of surgical approach on the histology of the femoral head following resurfacing of the hip.

Methods

We performed a histological assessment of the bone under the femoral component taken from retrieval specimens of patients having revision surgery following resurfacing of the hip. We compared the number of empty lacunae in specimens from patients who had originally had a posterior surgical approach with the number in patients having alternative surgical approaches.


Bone & Joint Research
Vol. 1, Issue 5 | Pages 86 - 92
1 May 2012
Amarasekera HW Roberts P Costa ML Parsons N Achten J Griffin DR Williams NR

Objectives

To study the vascularity and bone metabolism of the femoral head/neck following hip resurfacing arthroplasty, and to use these results to compare the posterior and the trochanteric-flip approaches.

Methods

In our previous work, we reported changes to intra-operative blood flow during hip resurfacing arthroplasty comparing two surgical approaches. In this study, we report the vascularity and the metabolic bone function in the proximal femur in these same patients at one year after the surgery. Vascularity and bone function was assessed using scintigraphic techniques. Of the 13 patients who agreed to take part, eight had their arthroplasty through a posterior approach and five through a trochanteric-flip approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 442 - 445
1 Apr 2008
Amarasekera HW Costa ML Foguet P Krikler SJ Prakash U Griffin DR

We used Laser Doppler flowmetry to measure the effect on the blood flow to the femoral head/neck junction of two surgical approaches during resurfacing arthroplasty. We studied 24 hips undergoing resurfacing arthroplasty for osteoarthritis. Of these, 12 had a posterior approach and 12 a trochanteric flip approach. A Laser probe was placed under radiological control in the superolateral part of the femoral head/neck junction. The Doppler flux was measured at stages of the operation and compared with the initial flux. In both groups the main fall in blood flow occurred during the initial exposure and capsulotomy of the hip joint.

There was a greater reduction in blood flow with the posterior (40%) than with the trochanteric flip approach (11%).