Spinal cord injury is an inevitable but rare occurrence in sports. Identifying trends and working to minimise risk is an integral part of sports management. All patients suffering a spinal cord injury in Scotland will be transferred to the Queen Elizabeth National Spinal Injuries Unit (QENSIU). Our records give an accurate account of trends in spinal cord injury. This study details the number of spinal cord injuries caused by sports and leisure pursuits in Scotland since 1992. 1451 patients have suffered a spinal cord injury in Scotland from 1992-2008. 142 (9.8%) arose from injuries during sport. The average age at injury was 32, and patients were predominantly male (91%). The commonest cause was diving (40, 28%) followed by cycling (29, 20%) climbing and hillwalking (15, 11%) and rugby union (12, 8%). Smaller numbers were seen in horse-riding (11), aerial sports (6), motor sports (6), snow sports (5), and football (5). Overall, there was evidence of an increasing trend in the number and severity of injuries in rugby and cycling. The number of spinal injuries, caused by diving, rugby and cycling remains disproportionally high and the increasing trends identified merit further investigation.
Patients with ankylosing spondylitis (AS) are vulnerable to cervical spine injury following relatively minor trauma. The authors present a retrospective review to determine the characteristics, treatment and outcome following cervical spine injury in these patients. Retrospective analysis of case notes and images of patients with AS admitted to the Spinal Injury Unit over a 10-year period.Purpose
Methods
Patients with spinal injuries are very vulnerable to early complications or secondary spinal cord injuries before and during transfer, which may delay their rehabilitation. We designed transfer guidelines following concerns raised in a pilot study of the transfer of 16 patients. We then examined the effectiveness of the guidelines in 100 consecutive patients and completed the cycle by re-auditing a further 254 consecutive admissions after incorporating changes from the initial audit. The transfer guidelines addressed ten areas of clinical concern. We recorded a 50% improvement in airway monitoring and management. There was also improvement in anti-ulcer therapy and thromboprophylaxis (from 50% to 96%). We saw a 50% improvement in the use of appropriate support staff during the transfer. The re-audit showed that initial improvements were maintained and further improvements were noted in the transfer of relevant documentation and investigations. Improvement was also noted in the use of a vacuum mattress for the transfer of spinal injury patients and subsequently reduced incidence of pressure sores by a statistically significant level, which helped in the early rehabilitation of these patients. The majority of transfers were safe. The transfer guidelines were easy to use and improved patient care by ensuring that common problems had been addressed before and during transfer. This system reduced the risk of preventable complications during inter-hospital transfer. There may be wider application of similar guidelines to other trauma patients who require inter-hospital transfer, where there is a possibility of preventable secondary injury.
After spinal cord injury (SCI) rapid muscle atrophy and extensive bone loss occur in the paralysed limbs resulting in increased fracture incidence (mostly at the epiphyses in the distal and proximal tibia and distal femur). We investigated whether re-introducing mechanical loading of the lower-limb bones in chronic SCI through exercise could induce bone formation, in accordance with Wolff’s Law. We present cross-sectional data from the Scottish paraplegic population illustrating the time course of bone loss after SCI, and review case studies describing musculoskeletal changes following lower-limb exercise interventions in chronic SCI. Reference data were obtained from 47 subjects with SCI at neurological levels T2 to L2, ranging from 6 months to 40 years post-injury. We used peripheral Quantitative Computed Tomography (XCT3000, Stratec, Germany) to scan 4 sites in the tibia and 2 in the femur, and evaluated trabecular, cortical, and total bone data, and soft-tissue parameters. Here, we focus on trabecular bone mineral density (BMDtrab) at the epiphyses, which provides an indicator of bone integrity. The same scans were performed pre- and post-training in chronic paraplegics who undertook a period of lower-limb exercise training (body-weight-supported treadmill training (BWSTT) or electrically-stimulated leg cycle (FES-cycle) training); these results are reviewed. The temporal pattern of bone loss is characterised by exponential decline in BMDtrab, reaching steady-state at 100 mg/cm3 in the distal tibia after 7 years and at 130 mg/cm3 in the distal femur after 3 years. A subject with incomplete SCI (18 years post-injury) showed an increase in BMDtrab in the distal tibia following 5-months BWSTT. In a separate study, subjects with complete SCI had varying responses to FES-cycle training. Bone loss appears to plateau after 7 years post-SCI. The effectiveness of physical interventions aimed at reversing bone loss in chronic SCI seemingly depends on the details of the associated bone-loading patterns.
Metal-on-metal (MOM) hip resurfacing devices are known to release metal ions locally and into the systemic circulation. Previous studies suggest that larger prosthetic head size will correlate to reduced wear properties and may result in lower systemic release of metal ions. This project assessed the effect of femoral head size on serum cobalt (Co) and chromium (Cr) levels in subjects after unilateral hip resurfacing with the Cormet 2000 prosthesis. We prospectively collected patient characteristics, outcome, and serum samples from device implanted subjects at six months, one, two, and three years following surgery. Serum Co/Cr levels were determined using high-resolution inductively coupled plasma mass spectrometry. Students t-test was used to compare ion levels in two groups based on femoral head size. Thirty-five subjects (twenty male) were followed. Co/Cr levels were increased at all time points when compared to control levels. A significant negative correlation was observed between Co and Cr levels and femoral head size. Co/Cr levels in subjects with larger femoral heads were significantly lower when compared to those implanted with smaller heads (Co, −35.8%; Cr, −33.0%). This correlated with significantly higher Co/Cr levels in females versus males, with females receiving significantly smaller heads on average. Elevated serum Co/Cr levels were observed at all time points following implantation and in females and in subjects with femoral heads.
SEREX was used to identify candidate tumor antigens in the nonimmunogenic fibrosarcoma (NFSA) tumor model. One of the six clones identified was of particular interest. NFSA-5 was identified as the receptor for hylaronan-acid-mediated motility (RHAMM), which is involved in cell growth and metastasis. RHAMM is expressed in a variety of human tumors. RHAMM is differentially expressed, with significant levels not found in normal tissues other than testis, placenta, and thymus. Therefore, RHAMM may be an appealing target for human tumor vaccines. The identification of murine homologs to human tumor antigens may aid in the preclinical development of human tumor vaccines. The goal of our studies was to use serological analysis of antigens by recombinant expression cloning (SEREX) to identify candidate tumor antigens in a nonimmunogenic murine fibrosarcoma model. SEREX provides a rapid means of identifying candidate tumor antigens in murine cancer models. The identification of murine homologs to human tumor antigens may aid in the preclinical development of human tumor vaccines. The SEREX approach included construction of a cDNA expression library from NFSA tumors followed by immunoscreening of the library with sera from C3H mice growing NFSA tumors. The nucleotide sequence of insert cDNA was determined for positive clones. Sequence alignments were performed with BLAST software on GenBank database. Six positive clones were identified. Two clones coded for proteins with known expression in normal tissues. Two clones represented heat-shock proteins, known to be upregulated in human and murine tumors. Two of the clones were of particular interest. Clone NFSA-1 was the homolog to NY-REN-58, an antigen previously identified by SEREX analysis of renal cell carcinoma patients. NFSA-5 was identified as the receptor for the hylaronan-acid-mediated motility (RHAMM), which is involved in cell growth and metastasis. RHAMM was recently identified as a leukemia-associated antigen and is expressed in a variety of human solid tumors including renal cell carcinoma, breast carcinoma, and ovarian carcinoma. RHAMM is differentially expressed, with significant levels not found in normal tissues other than testis, placenta, and thymus. Therefore, RHAMM may be an appealing target for human tumor vaccines.
To determine whether sacral chordoma is monoclonal or polyclonal in origin, a new assay to study the polymorphic human androgen receptor locus (HUMARA) was applied. The ratio of maternal inactive X-chromosone to the paternal inactive X (Lyon hypothesis) was determined via a methylation-specific polymerase chain reaction (PCR) technique. Seven of seven informative samples showed a polyclonal proliferation pattern. This study suggests that chordomas are more comparable to mesenchymal neoplasms than to monoclonal hematopoeitic neoplasms. The purpose of this study was to determine whether sacral chordoma is monoclonal or polyclonal in origin via a new molecular genetic assay of the x-chromosome. A polyclonal proliferation pattern was identified in all informative samples studied. Characterization of the genetic tumorigenesis of this unpredictable neoplasm may lend insight into its biological behavior and offer novel therapeutic intervention. Utilizing a new assay to study the polymorphic human androgen receptor locus (HUMARA), the ratio of maternal inactive X-chromosome to the paternal inactive X (Lyon hypothesis) is determined via a methylation-specific polymerase chain reaction (PCR) technique to detect X-chromosome polymorphisms. Eight female chordoma patients had their DNA harvested and their x-chromosome inactivation pattern and polymorphisms determined and compared to control. A polyclonal proliferation pattern was identified in seven of seven informative samples. The eighth sample showed a single x chromosome allele in normal and tumor tissue and was thus viewed as uninformative.
Infection is one of the major reasons leading to early revision of total hip joint replacements. Traditionally, samples have been taken for microscopy, culture and sensitivity at the time of surgery. However, this doesn’t always reveal a causative organism. Molecular techniques have now been refined to improve sensitivity in bacterial detection. In this study, samples were taken from acetabular and femoral components at the time of revision hip surgery for suspected infection. These underwent conventional culturing and also PCR and DNA sequencing. The white cell count, CRP and ESR were also recorded. Results are available for 6 cases. All of these patients had an elevated CRP level (17–169). Microscopy at the time of surgery showed scanty white cells and no organisms on at least 1 sample from 2 cases. Subsequent culture was negative. When sonication techniques were used to remove bacterial DNA, followed by PCR and sequencing, one of these cases yielded
This study demonstrated that we may be under-diagnosing infection in hip revision patients. These new techniques could prove invaluable in detecting low yet significant levels of bacteria which may lead to a change in current antibiotic policy for joint replacements and subsequently a reduction in the number of revisions required for loosening due to infection.
Substantial bone loss and bone defects are the most challenging problems faced by the surgeon performing revision surgery. Of the many techniques available, impaction bone grafting aims to achieve stability of an implant with the use of compacted, morselized bone graft and subsequently allows restoration of bone stock by bone ingrowth. This technique was proposed with a highly polished double tapered stem. This technique has also been subsequently used with stems of varying surface finish and shape. We report here our experience with impaction grafting using Charnley stem and variants with 8–10 year results assessing the radiological appearance and subsequent behaviour of the impacted allograft. A prospective radiological study of revision hip arthroplasty done for aseptic loosening with femoral bone loss is presented. Pre operative bone loss was assessed using the Endo Klinik grading system. Impaction grafting with fresh frozen femoral head allograft and the flanged 40 size Charnley stem was used in 17 cases and extra heavey flanged 40 size was used in 9 casaes. Post operative and annual review radiographs were examined for graft distribution, graft consolidation, cortical repair and subsidence of the stem. Twenty six revisions performed in 25 patients between May 1994 and November 1996 were followed up for 8–10 years. Mean age was 66 years(range 26–83 years). There were eighteen male and 7 female patients. One patient died 2 years and 9 months after the operation. Pre operatively Endo Klinik grade 2 bone loss was seen in 7 cases and grade 3 bone loss was seen in 19 cases. Post operative radiographs showed even graft distribution in twenty cases, five patients had poor filling in Gruen zone 3 and one patient had poor filling in zone 2. All cases demonstrated evidence of graft consolidation by one year. Twenty two cases showed no further changes after 8–10 years. Two cases of subsidence have been revised and one patient is awaiting revision ( 8 years after revision). Two of these were extra heavy flanged 40 stems. Three cases showed subsidence >
5mm and were associated with graft deficiency in zone 2 or 3. Out of these three one had an extra heavy flanged 40 stem inserted. There were no medical complications or deep infection following surgery in these patients. One patient had dislocation. In conclusion, femoral revision using impaction grafting with the Charnley stem produces satisfactory radiological results in the medium to long term. Good graft distribution on a postoperative radiograph is associated with graft consolidation, cortical repair and minimal stem subsidence. Extra heavy flanged 40 stems perform less satisfactorily compared to the flanged 40 stems. Inadequate graft filling is associated with stem subsidence and revision. These findings highlight the importance of meticulous surgical technique to ensure even graft distribution. This study supports the taper of the Charnley stem and suggests that a vaquasheen finish is not contraindicated.
Low Contact Stress(LCS) total knee arthroplasty was developed to reduce contact stress on the bearing surface and to minimise stresses at the interface between the host bone and the implant surface leading to long term implant survival. The rotating platform was introduced as the bearing interface when both cruciates are sacrificed. It has a central cone which engages into a matching cone in the tibial tray. This allows unconstrained axial rotation of the bearing surface. However, this potentially leaves the platform susceptible to subluxation/dislocation. The reported rate of this complication varies from 0.5% to 4.65%. In this study from a single center we report the incidence and highlight the associated causative factors found in our series. There were 1053 Low Contact Stress total knee arthroplasties performed between 1994 and 2003. We reviewed 10 knees in 9 patients who had dislocation of the polyethylene rotating platform. This amounts to 0.95% in our series. All the patients with dislocation were women. Average age was 72 years(range 62–84). Osteoarthritis was the primary diagnosis in 8 patients. One patient was suffering from rheumatoid arthritis was on long term steroid therapy and had bilateral dislocations. One patient with Osteoarthritis with Parkinson’s disease went onto have 2 recurrent dislocations. Pre-operative deformity was varus in 9 knees(range 4–10 degrees) and valgus of 15 degrees was noted in one. Time from index operation to dislocation ranged from as early as 10 days to 10 months. There was history of trauma and acute presentation only in one patient. In one patient the knee dislocated while she twisted her knee in bed and in another while climbing up the stairs. In the remaining seven patients the presentation was subacute with symptoms such as pain, decreased range of motion, swelling and a clunking sensation while walking. Although manipulation under anaesthesia was successful in 3 patients, all of them had recurrent dislocations and two patients had revision to a deepdish platform. Failed closed reduction led to open reduction in two patients with replacement of the rotating platform to deepdish (12.5 mm) type in one. Following both procedures knee was immobilised in a cast for 6 weeks. Five patients were directly revised without attempting closed reduction to a deepdish rotating platform. At revision in all cases the platform was found to be rotated medialy and posteriorly. Soft tissue imbalance and laxity were seen in all but one. At an average followup of 48.5 months (range 11–84 months) no patient had recurrent instability. Increasing age, questionable soft tissue integrity and varus deformity were significantly associated with rotating platform dislocation. Closed reduction may be possible but invariably leads to recurrence of dislocation and open reduction with revision of the rotating platform gives reliable results. Replacing the rotating platform with a thicker deepdish bearing provides satisfactory stability at revision surgery. Meticulous surgical technique with accurate soft tissue balancing are important in reducing the incidence of dislocations.
We followed prospectively 69 patients with 78 proximal femoral allografts performed for revision of total hip arthroplasty for an average of 36 months (range 29 to 68). Large fragment proximal femoral allografts and cortical strut allografts were successful in 85%. Grafts smaller than 3 cm in length (calcar grafts) were clinically successful in 81%, but 50% underwent significant radiographic resorption. We conclude that large proximal femoral allografts and cortical strut allografts provide dependable reconstruction of bone stock deficiencies during revision total hip arthroplasty.