The aim of this study was to study the short-term outcome of a contemporary modular revision knee system used in our centre for managing Knee revision arthroplasty Preoperative, one and two years follow up scores and radiographic analysis were recorded from 72 consecutive knee revision cases performed between 2006 and 2008. Outcome measures included the American Knee Society (AKSS), Oxford (OKS) and WOMAC scores and range of motion. The radiographic assessment included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre=op/post-op) was deemed satisfactory.PURPOSE
METHODS