Austin Moore cervicocephalic prostheses have been a therapeutical option for femoral neck fractures in patients with a reduced general condition for many years. Since treatments other than total hip arthroplasties have also been included in National arthroplasty registers during the last decade, adequate reference data for comparative analyses have recently become available. Based on a standardised methodology, a comprehensive literature analysis of clinical literature and register reports was conducted. On the one hand, the datasets were examined with regard to validity and the occurrence of possible bias factors, on the other hand, the objective was to compile a summary of the data available. The main criterion is the indicator of Revision Rate. The definitions used with respect to revisions and the methodology of calculations are in line with the usual standards of international arthroplasty registers.Introduction
Materials and Methods
By contrast, worldwide Register data refer to 733,000 primary operations, i.e. approximately 10 times as many as sample-based datasets. In general, sample-based datasets present higher revision rates than register data. The deviations are high, with a maximum factor of 64 for hip stems. Whereas the AAHKS survey exhibits lower deviations than the monocentre trials, they are still too high for this data collection tool being considered as reliable and safe to provide valid data for general conclusions. The incidence of implant fractures after total hip arthroplasty in pooled worldwide arthroplasty register datasets is 304 fractures per 100.000 implants. In other words, one out of 323 patients has to undergo revision surgery due to an implant fracture after THA in their lifetime.
For the detection of rare, but severe complications like implant fractures sample-based studies achieve the goal of providing accurate figures only to a very limited extent, even if the samples are large. Here, too, comprehensive national arthroplasty registers are the most suitable tool to identify such incidents and calculate reliable figures. Contrary to the prevalent opinion, implant fractures still are a relevant problem in arthroplasty.
Compared to other implants for unicompartmental knee arthroplasty in worldwide arthroplasty Registers, the Oxford Uni shows good results. For the assessment of the outcome of implants, register data are to be rated superior and, in terms of reference data for the detection of potential bias factors in the clinical literature, can provide an essential contribution for scientific meta-analyses.
In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years. After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial unicompartmental replacement. After total ankle replacement a mean of 3.29 revisions per 100 observed component years was seen. The outcomes of total hip and knee replacement are almost identical. Revision rates of about 6% after five years and 12% after ten years are to be expected.