Objective of this study was to analyse results of two stage revisions in infected megaprostheses in lower limb.
Infection occurred in 80 cases (7.7%) at mean time of 4 yrs (min 1 month, max 19 yrs) in 18 KMFTR®, 47 HMRS®, 5 HMRS® Rotating Hinge, 10 GMRS®. Sites: 51 distal femurs, 21 proximal tibias, 6 proximal femurs, 1 total femur and 1 extrarticular knee resection. Most frequent bacteria causing infection were: Staphilococcus Epidermidis (39 cases), Staphilococcus Aureus (17) and Pseudomonas Aeruginosa (5). Infection occurred postoperatively within 4 weeks in 9 cases, early (within 6 months) in 12 cases, late (after 6 months) in 59 cases. Usual surgical treatment was “two stage” (removal of implant, one or more cement spacers with antibiotics, new implant), with antibiotics according with coltures. One stage treatment was used for immediate postoperative infections, only since 1998. Functional results after treatment of infection were assessed using the MSTS system.
In 3 cases an amputation was primarily performed, to proceed with chemotherapy. Revisions for infection were successful in 63 pts (79%), while 17 pts were amputated (21%). Functional results evaluated in 53 revised cases were good or excellent in 43 (81.1%).
Patients included 44 females and 38 males, ranging in age from 14 to 74 years. Mean follow-up was 9.5 years (min. 3, max. 27). Histopathological findings included chordomas in 55 cases and giant cell tumor (GCT) in 27. Most pts. had iv antibiotic therapy with amikacin and teicoplanin. Surgery of chordoma was resection, surgery of GCT was intralesional excision. In 6 sacral resections a miocutaneous transabdominal flap of rectus abdominis was used for posterior closure.
Mean surgical time was 14 hours for resections and 6 hours for excisions. No significant difference was found comparing deep wound infections with levels of resection (15/33 resections proximal to S3-45% and 8/19 resections below or at S3-42%), previous intralesional surgery elsewhere (4/9 patients previous treated elsewhere-44% and 19/46 primarily treated patients-41%) and age at surgery.
S. Epidermidis and S. Aureo were the most frequent bacteria causing infection (45%). Two stage treatment of infection was chosen: removal of the implant and temporary substitution with cement spacer with antibiotics (usually vancomycin) until infection healed. But a new prostheses was actually implanted in 3 cases only (at mean time of 5.7 mos), while in 17 the spacer was never removed by patients choice due to the acceptable result with the spacer. Systemic antibiotics were associated according to cultural results. Infection healed in all patients.
Gorham-Stout disease (GSD) is rare, characterized by proliferation of vascular channels resulting in progressive distruction of bone. In the Rizzoli files we found 15 cases of GSD from 1968 to 2008. Two were excluded for insufficient documentation. For 13 cases clinical data, imaging and histology were analysed. Histopathologic features included benign vascular proliferation, vascular pattern of osteolytic angioma, fibro-connective tissue component and bony destruction. A final diagnosis was established based on clinical, radiological and histopathologic features. Imaging included X-rays in 11 cases and CT or MRI in 5. All lesions were lytic, with associated sclerosis in two cases. There was one lesion only in 4 cases, multiple lesions in the same bone in 1 and multiple bones involved in 6. Primary sites were proximal femur in 7 cases, pelvis in 2, hip and knee, calcaneus, humerus and cervical spine in 1 case each. Two patients had no treatment, 2 conservative treatment (cast or brace), 5 surgery, 6 medical treatment (byphosphonates, calcitonin, zoledronic acid, interferon, steroids), 1 radiotherapy, 2 selective arterial embolization. Surgery consisted of internal fixation of pathologic fractures in 4 patients and reconstruction of the entire humerus with a double composite allograft in 1. Treatment was surgery only in 2 patients, medical treatment in 4 (1 also embolization), surgery and medical treatment in 2 (1 also embolization), radiotherapy only in 1, conservative treatment in 2. Four patients were lost at follow up. Mean follow up was 17 ys.(min 2, max 30) in 9 patients: 2 dead, 3 healed, 3 with stable disease, 1 alive with disease at 24 ys. No conclusive treatment recommendations are possible; surgery is indicated in pathologic fractures or reconstruction of massively destroyed bones, medical treatment and selective embolization are helpful. In literature prosthetic reconstruction is preferred due to the risk of allografts resorption.
Between 1983 and 2006 at Rizzoli 669 knee modular uncemented prostheses were implanted after resection of the distal femur, total femur or proximal tibia. These prostheses include 126 KMFTR prostheses and 543 second generation HMRS prostheses. Patients were followed periodically in the clinic. Data was obtained from clinical charts and imaging studies with special attention to major complications requiring revision surgery. Revision for polyethylene wear was considered a minor complication, since it did not imply failure of the implant. Functional results were assessed according to the MSTS system. Since data could be misleading due to deaths in an oncologic population (although 2/3 of patients were cured or long survivors), to censore the implant unrelated events Kaplan-Meyer curves of implant survival were studied. In 126 KMFTR group infection rated 13.5%, stem breakage 13%, aseptic loosening 9.5%; change of polyethylene rated 44%. In 543 HMRS prostheses infection rated 8.6%, stem breakage 3%, aseptic loosening 4.8%; revision for polyethylene wear rated 9.6%. Techniques of revisions and their outcome analysed showed about 2/3 of good results, but increased risk of further complications in revised implants. Functional results (MSTS system) were good or excellent in 80% of KMFTR prostheses and in 90% of HMRS. Decrease of major complications in newer prosthetic design was statistically significant and possibly due to newer materials and modified stem design. Polyethylene wear also decreased significantly. Function was satisfactory in most patients without complications for both groups. Revision surgery is technically demanding and appropriate timing of revision is crucial, since early treatment can improve final outcome.
From October 2003 to September 2007 at Rizzoli 161 GMRS® prostheses were implanted after resections of the lower limb. This is a modular system with a knee rotating hinge mechanism, cemented and uncemented stems, in titanium and chromium-cobalt-molybdenum, curved and straight-fluted, with or without hydroxyapatite coating. Adaptors are available to revise HMRS® prostheses with hybrid implants. This study includes 88 males and 73 females ranging in age from 9 to 80 years. Sites of reconstruction were 109 distal femurs, 19 proximal femurs, 1 total femur and 32 proximal tibias. There were 149 oncologic and 12 non oncologic diagnoses, including 96 primary reconstructions and 65 revisions for failures of previous reconstructions. Analysis of imaging and complications was performed and function assessed according to MSTS system. Kaplan-Meier curves were used to statistically evaluate implant survival. At a mean follow up of 2.5 yrs. 106 patients are continuously NED, 31 NED after treatment of relapse, 7 AWD, 5 DWD. There were 10 major complications: 8 infections (4.7%) (5 in primary and 3 in secondary implants) and 2 aseptic loosenings (1.2%) (1 each). There were 9 minor complications requiring minor revisions. Comparative statistical analysis of implant survival showed no statistically significant difference between primary and secondary implants. Functional results were good or excellent in 95% of patients, without any poor. Middle term results are promising with no breakages of implant components. Besides oncological cases, there are selected indications in non oncological settings, such as revisions of prosthetic or allografts failures. While a higher complication rate was expected in secondary implants, statistical analysis shows similar survival.