Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 193 - 199
1 Feb 2022
Wang Q Wang H A G Xiao T Kang P

Aims

This study aimed to use intraoperative free electromyography to examine how the placement of a retractor at different positions along the anterior acetabular wall may affect the femoral nerve during total hip arthroplasty (THA) when undertaken using the direct anterior approach (THA-DAA).

Methods

Intraoperative free electromyography was performed during primary THA-DAA in 82 patients (94 hips). The highest position of the anterior acetabular wall was defined as the “12 o’clock” position (middle position) when the patient was in supine position. After exposure of the acetabulum, a retractor was sequentially placed at the ten, 11, 12, one, and two o’clock positions (right hip; from superior to inferior positions). Action potentials in the femoral nerve were monitored with each placement, and the incidence of positive reactions (defined as explosive, frequent, or continuous action potentials, indicating that the nerve was being compressed) were recorded as the primary outcome. Secondary outcomes included the incidence of positive reactions caused by removing the femoral head, and by placing a retractor during femoral exposure; and the incidence of femoral nerve palsy, as detected using manual testing of the strength of the quadriceps muscle.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 179 - 179
1 May 2012
R. B A. G K. W D. B W. A B. D J. W P. F
Full Access

Background

The Kotz Modular Femoral Tibial Replacement system has been one of the most widely utilised uncemented modular systems for bone and joint reconstruction after tumour resection. We have identified a significant incidence of mechanical failure and breakage of the prosthesis. The purpose of this investigation is to review the modes of implant failure and the outcomes after prosthetic revision for a broken Kotz prosthesis.

Methods

Over 20 years there were 121 distal femoral, 55 proximal tibial, 47 proximal femoral and 12 total femoral replacements performed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 123 - 123
1 May 2012
P. L A. S G. R D. B O. S A. G
Full Access

Introduction

Young, high-demand patients with large post-traumatic tibial osteochondral defects are difficult to treat. Fresh osteochondral allografting is a joint-preserving treatment option that is well-established for such defects. Our objectives were to investigate the long-term graft survivorships, functional outcomes and associated complications for this technique.

Methods

We prospectively recruited patients who had received fresh osteochondral allografts for post-traumatic tibial plateau defects over 3cm in diameter and 1cm in depth with a minimum of 5 years follow-up. The grafts were retrieved within 24 hours, stored in cefalozolin/bacitracin solution at 4°C, non-irradiated and used within 72 hours. Tissue matching was not performed but joints were matched for size and morphology. Realignment osteotomies were performed for malaligned limbs. The Modified Hospital for Knee Surgery Scoring System (MHKSS) was used for functional outcome measure. Kaplan-Meier survivorship analysis was performed with conversion to TKR as end point for graft failure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 116 - 116
1 May 2012
G. R P. L O. S D. B A. G
Full Access

Background

An osteochondral defect in the knees of young active patients represents a treatment challenge to the orthopaedic surgeon. Early studies with allogenic cartilage transplantation showed this tissue to be immunologically privileged, showed fresh grafts to maintain hyaline cartilage, and surviving chondrocytes several years after implantation.

Methods

Between January 1978 and October 1995 we enrolled 63 patients in a prospective non-randomised study of fresh osteochondral allografts for post-traumatic distal femur defects in our institute. Five international patients who were lost to follow-up were excluded from this study. The indications for the procedure were: patients younger than 50 years of age having unipolar post-traumatic defects, or osteochondritis dissecans larger than three cm in diameter and one cm in depth.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 182 - 182
1 May 2012
R. B K. W W. A D. B A. G P. F J. W R. B
Full Access

Introduction

Pathologic humerus fractures secondary to metastases are associated with significant pain, morbidity, loss of function, and diminished quality of life. Here we report our experience with stabilisation using intramedullary polymethylmethacrylate (PMMA) cement and non-locking plates.

Methods

A retrospective review was undertaken of patients treated at a tertiary musculoskeletal oncology centre from 1989 to 2009. Patients who underwent surgery for an impending or completed pathologic humerus fracture with a diagnosis of metastatic disease or myeloma were included. All patients underwent intralesional curettage of the tumour followed by fixation with intramedullary PMMA and plating.