Objectives. This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted
Objectives.
There has been significant interest in day-case and rapid discharge pathways for
Abstract. Background. The Oxford Domed Lateral (ODL)
In recent years, reduction in the length of stay in patients undergoing UKA has gained considerable interest. This has led to development of ‘fast-track' and even day-case protocols aimed at decreasing length of stay (LOS), enhancing post-operative recovery and decreasing post-operative morbidity. One potential barrier to faster discharge and patient recovery is the need for post-operative haemoglobin checks and allogenic blood transfusion; which has been shown to increase LOS. Allogenic blood transfusion itself is not without risk, including immunological reactions, transfusion associated lung injury, infection and transmission of disease, thus reducing blood loss and the need for transfusion is imperative. Currently there is a knowledge gap regarding post-operative transfusion need and blood loss following UKA. We aimed to investigate blood loss and transfusion rates following UKA. Our primary aim was to evaluate the extent of post-operative transfusion need following UKA and identify which patients are at higher risk of needing transfusion. Following institutional approval, a retrospective analysis of all patients undergoing
Background. In the United Kingdom (UK), the fastest growing population demographic is the over 85 years of age, but despite this, outcomes achieved in the octogenarian population with a
Summary Statement. This project proves that Patellofemoral (PF) joint degeneration is not a contraindication to medial unicompartmental knee replacement. Introduction.
Great interest in
UKA with mobile bearing is a one of the treatment of medial osteoarthritis. However, some reports refer to the risk of dislocation of the mobile bearing. Past reports pointed out that medial gap might be enlarged in deep flexion position (over 120 degrees), and says that it will lead to instability of the mobile bearing. The purpose of this study is to research the risk factors of enlargement of medial gap in deep flexion position. We performed 81 UKAs with mobile bearing system from November 2013 to December 2015, and could evaluate 41 knees. This study of 41 knees included 9 males and 32 females, with average operation age of 75.4years(63–89years). The diagnosis was osteoarthritis in 39 knees and osteonecrosis in 2 knees. The UKA(Oxford partial knee microplasty, Biomet, Warsaw, IN) was used in all cases. We performed distal femur and proximal tibia osteotomy using CT-Free navigation system(Stryker Navigation System II/precision Knee Navigation ver4.0). And we inserted femoral and tibial trial component, then we placed an UKA tensioner on the medial component of the knee. Using tensioner under 30 lbs, we measured joint medial gap at 0,20,45,90,130(deep flexion) degrees. When we compared medial gap at 90 degrees position with at 130 degrees, we defined it as ‘instability group’ if there was gap enlargement more than 1mm, and defined it as ‘stability group’ if there wasn't. We compared this two groups with regard to age, BMI, femoro-tibial angle (FTA), the diameter of anterior cruciate ligament (ACL), tibial angle and tibial posterior slope angle of the implant. We evaluated preoperative and postoperative FTA by weightbearing long leg antero-posterior alignment view X-rays. We measured ACL diameter at its condyle level in coronal view of MRI. Also we evaluated tibial component implantation angle by postoperative CT using 3D template system. These measurement were analyzed statistically using The stability group contained 26 knees, and the instability group contained 15 knees. Compared with the stability group, the instability group indicated higher FTA (p=0.001). Between 20 and 90 degrees flexion position, there was no change of medial gap. Dislocation of the mobile bearing is one of the complications of UKA and it will need re-operation. It is said to be caused by impingement of the bearing and osteophyte of femur. However, some reports said that dislocation was happened when the knee was flexed deeply or twisted, and there was no impingement. We think it may means that dislocation could be caused by medial gap enlargement. This study indicates that higher FTA could be risk factor of dislocation of mobile bearing. It is important to evaluate preoperatively FTA by X-ray.
The purpose of this study is to evaluate accuracy of tibia cutting and tibia implantation in UKA which used navigation system for tibia cutting and tibia component implantation, and to evaluate clinical results. We performed 72 UKAs using navigation system from November, 2012. This study of 72 knees included 56 females and 16 males with an average operation age of 74.2 years and an average body mass index (BMI) of 24.8 kg/m2. The diagnosis was osteoarthritis (OA) in 67 knees and osteonecrosis (ON) in 5 knees. The UKA (Oxford partial knee microplasty, Biomet, Warsaw, IN) was used all cases. We evaluated patients clinically using the Japanese orthopaedic association (JOA) score, range of motion (ROM), operation time, the amount of bleeding and complications. Patients were evaluated clinically at preoperation and final follow up in JOA score and ROM. As an radiologic examination, we evaluated preoperative and postoperative lower limb alignment in FTA (femoro-tibial angle) by weightbearing long leg antero-posterior alignment view X-rays. Also we evaluated a tibial component implantation angle by postoperative CT, and tibia cutting angle by intraoperative navigation system. We defined the tibial angle which a tibia functional axis and the tibia component made in coronal plane, also tibial posterior slope angle which a tibia axis and tibia component made in sagittal plane by CT. We measured tibial angle and tibial posterior slope angle by 3D template system. We performed UKA in all cases mini-midvastus approach. At first we performed osteotomy of the proximal medial tibia using CT-Free navigation. At this procedure we performed osteotomy to do re-cut if check did cutting surface in navigation, and there was cutting error (>3°), and then to do check again in navigation. Next we did not use navigation and went the osteotomy of the distal femur with an IM rod and drill guide of microplasty system. And then we performed a trial and decided bearing gap and moved to cementing. At first we went cementing of the tibia component. At this procedure we went to drive implant again if check did implant surface in navigation, and there was implantation error(>3°), and to do check. We checked did tibia cutting, tibia implantation carefully in navigation. In addition, We sterilize a clips and use it came to be in this way possible for the check of the first osteotomy side exactly. ROM was an average of 122.7° of preoperation became an average of 128.2° at final follow up, and JOA score was an average of 50.5 points of preoperation improved an average of 86.6 points at final follow up after UKA. An average of the operation time was 94 minutes, an average of the amount of bleeding was 137.7ml, and complications were one proximal type deep venous thrombosis (DVT) and one pin splinter joining pain by navigation, .Asetic loosening(tibial component) was one case, and this conversed the TKA. In the radiologic evaluation, FTA was an average of 182.1° of preoperation corrected an average of 175.9°after UKA. In other words, an average of 6.2° were corrected by UKA. The tibia component implantation angle was an average of 90.18° in a measurement by the CT after UKA, intoraoperative tibia component implantation angle was an average of 90.32° in a measurement by the navigation system. These two differences did not accept the significant difference at an average of 1.33°.(P=0.5581). Similarly, the posterior slope angle were as follow; average of 5.65°by CT and average of 5.75°by navigation. These two differences did not accept the significant difference at an average of 1.33°. (P=0.6475) Discussion: We performed UKA using navigation and evaluated the implantation accuracy for tibia osteotomy, tibia implantation. They were good alignment with an average of 90.18°, and outliers more than 3° were two cases(2.8%). It will be necessary to examine long-term progress including clinical results complications in future. We are performed UKA now in femur side using PSI(patient specific instruments) and tbia side using Navigation.
Introduction. Knee arthroplasty (KA), encompassing Total Knee Replacement (TKR) and
Introduction and Objective. In recent studies, robotic-assisted surgical techniques for
Details of orthopaedic implants in Scotland are recorded on a national database. The results are used by the Scottish Arthroplasty Project to record survival and complication rates for both knee and hip replacements. The aim of our study was to assess the accuracy of recorded data for
Polyethylene wear of joint replacements can cause severe clinical complications, including; osteolysis, implant loosening, inflammation and pain. Wear simulator testing is often used to assess new designs, but it is expensive and time consuming. It is possible to predict the volume of polyethylene implant wear from finite element models using a modification of Archard's classic wear law [1–2]. Typically, linear elastic isotropic, or elasto-plastic material models are used to represent the polyethylene. The purpose of this study was to investigate whether use of a viscoelastic material model would significantly alter the predicted volumetric wear of a mobile-bearing
Study of failed Oxford medial unicompartmental knee replacements at the Royal Cornwall Hospital. Objective. we set up a retrospective study to identify the various reasons for failure of oxford medial unicompartmental knee replacements and to assess their outcome following revision. Materials and Method. Over 5 years (2006- 2010) we identified 26 failed
Background. Despite an ageing population and a rise in the number of joint replacements being performed, the mean age of patients undergoing surgery remains static. One explanation for this is continued concern over the risks of performing surgery on the very elderly. We aim to investigate the outcome of Total Knee Replacement (TKR) in a nonagenarian population. Methods. The Elective Orthopaedic Centre, Epsom has an established patient reported outcome measures (PROMs) programme into which all patients are routinely enrolled. We retrospectively reviewed our data set for a cohort of nonagenarians undergoing primary TKR, between April 2008 and October 2011. Post-operative complications, mortality rates and functional outcomes were compared to those of a time matched 70–79 year old cohort. Only patients with a primary diagnosis of osteoarthritis were included whereas an exclusion criterion consisted of patients undergoing revision surgery, simultaneous bilateral replacements or conversion from a