Advertisement for orthosearch.org.uk
Results 1 - 20 of 55
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 983 - 989
1 Nov 1998
Murray DW Goodfellow JW O’Connor JJ

Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by unicompartmental arthroplasty using fully congruous mobile polyethylene bearings. At review, 34 knees were in patients who had died and 109 were in those who were still living. The mean elapsed time since operation was 7.6 years (maximum 13.8). We established the status of all but one knee. There had been five revision operations giving a cumulative prosthetic survival rate at ten years (33 knees at risk) of 98% (95% CI 93% to 100%). Considering the knee lost to follow-up as a failure, the ‘worst-case’ survival rate was 97%. No failures were due to polyethylene wear or aseptic loosening of the tibial component. One bearing which dislocated at four years was reduced by closed manipulation. The ten-year survival rate is the best of those reported for unicompartmental arthroplasty and not significantly different from the best rates for total knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 653 - 657
1 Jul 2002
Robinson BJ Rees JL Price AJ Beard DJ Murray DW Smith PM Dodd CAF

When the Oxford unicompartmental meniscal bearing arthroplasty is used in the lateral compartment of the knee, 10% of the bearings dislocate. A radiological review was carried out to establish if dislocation was related to surgical technique. The postoperative radiographs of 46 lateral unicompartmental arthroplasties were analysed. Five variables which related to the position and alignment of the components were measured. Dislocations occurred in six knees. Only one of the five variables, the proximal tibial varus angle, had a statistically significant relationship to dislocation. This variable quantifies the height of the lateral joint line. The mean proximal tibial varus angle for knees the bearings of which had dislocated was 9° and for those which had not it was 5°. In both groups it was greater than would be expected in the normal knee (3°). Our study suggests that a high proximal tibial varus angle is associated with dislocation. The surgical technique should be modified to account for this, with care being taken to avoid damage to or over-distraction of the lateral soft tissues


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 89 - 89
1 Mar 2012
Sarasin S Lewis J Padgett J Davies A
Full Access

Patellofemoral unicompartmental joint replacement is a controversial subject with a relatively small evidence base. Of the 50,000 total knee arthroplasties performed each year in the UK, approximately 10% are performed for predominantly patellofemoral arthritis. There are several patellofemoral unicompartmental prostheses on the market with the National Joint Registry recording 745 such prostheses used in 2007. Most evidence in favour of this procedure comes from experience with the Avon prosthesis (Stryker) predominantly from designer-surgeons. The FPV patellofemoral joint replacement (Wright Medical) has been in use in Europe for several years. The instruments have recently been redesigned and the device marketed in the UK. In 2007 the FPV had 5.9% market share (n=44). We present our early experience with the FPV patellofemoral joint replacement, which to our knowledge, is the first clinical outcome series for this prosthesis. 33 consecutive FPV joint replacements in 29 patients were performed between April 2007 and September 2009 for unicompartmental patellofemoral OA. All cases were performed or directly supervised by the senior author. Results are presented with a minimum follow-up of six months. Oxford and American Knee Society scores (AKSS) were obtained on all patients preoperatively and at subsequent outpatient visits. Mean preoperative AKSS knee score was 49.7 points and postoperative scores at 6 months and 1 year were 82.5 and 86.4 respectively. Mean Oxford score preoperatively was 30.4 (37%) and at 6 months and 1 year were 21.3 (56%) and 11.2 (77%) respectively. There were no complications related to the implant. One knee required a secondary open lateral release due to inadequate balancing at the index procedure. Further medium to long-term follow up data are required, but our initial experience with this device is encouraging


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 783 - 789
1 Sep 1999
Weale AE Murray DW Crawford R Psychoyios V Bonomo A Howell G O’Connor J Goodfellow JW

We determined the outcome of 56 ‘Oxford’ unicompartmental replacements performed for anteromedial osteoarthritis of the knee between 1982 and 1987. Of these, 24 were in patients who had died without revision, one was lost to follow-up and two had been revised. Of the remaining 29 knees, 26 were examined clinically and radiologically, two were only examined clinically and one patient was contacted by telephone. The mean age of the patients was 80.3 years. At a mean follow-up of 11.4 years (10 to 14) the measurements of the knee score, range of movement and degree of deformity were not significantly different from those made one to two years after operation, except that the range of flexion had improved. Comparison of fluoroscopically-controlled radiographs at a similar interval of time showed no change in the appearance of the lateral compartments. The retained articular cartilage continued to function for ten or more years which suggests that anteromedial osteoarthritis may be considered as a focal disorder of the knee. This justifies continued efforts to develop methods of treatment which preserve intact joint structures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 22 - 22
1 Oct 2020
Dodd CAF Kennedy J Murray DW
Full Access

Background

Lateral Unicompartmental Knee Arthroplasty (UKA) is a recognised treatment option in the management of lateral Osteoarthritis (OA) of the knee. Whilst there is extensive evidence on the indications and contraindcations in Medial UKA there is limited evidence on this topic in Lateral UKA. The aim of this study was to assess our experience of mobile lateral UKR and to look specifically at the effect of Contraindications on the outcome.

Method

A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and presence of full- thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 791 - 800
19 Oct 2023
Fontalis A Raj RD Haddad IC Donovan C Plastow R Oussedik S Gabr A Haddad FS

Aims. In-hospital length of stay (LOS) and discharge dispositions following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, it is imperative to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge dispositions following robotic arm-assisted total knee arthroplasty (RO TKA) and unicompartmental arthroplasty (RO UKA) versus conventional technique (CO TKA and UKA). Methods. This large-scale, single-institution study included patients of any age undergoing primary TKA (n = 1,375) or UKA (n = 337) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for post anaesthesia care unit (PACU) admission, anaesthesia type, readmission within 30 days, and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge. Results. The median LOS in the RO TKA group was 76 hours (interquartile range (IQR) 54 to 104) versus 82.5 (IQR 58 to 127) in the CO TKA group (p < 0.001) and 54 hours (IQR 34 to 77) in the RO UKA versus 58 (IQR 35 to 81) in the CO UKA (p = 0.031). Discharge dispositions were comparable between the two groups. A higher percentage of patients undergoing CO TKA required PACU admission (8% vs 5.2%; p = 0.040). Conclusion. Our study showed that robotic arm assistance was associated with a shorter LOS in patients undergoing primary UKA and TKA, and no difference in the discharge destinations. Our results suggest that robotic arm assistance could be advantageous in partly addressing the upsurge of knee arthroplasty procedures and the concomitant healthcare burden; however, this needs to be corroborated by long-term cost-effectiveness analyses and data from randomized controlled studies. Cite this article: Bone Jt Open 2023;4(10):791–800


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 56 - 56
1 Mar 2012
Arumilli B Ng A Oyekanmi F Patel A Ellis D Hirst P
Full Access

Background. The cemented mobile bearing metal backed low contact stress patellofemoral arthroplasty (LCS PFA) is a newer design belonging to the second generation of inlay type implant, based on the more successful knee arthroplasty model. The advantage is the patella can articulate with the trochlear implant as well as the femoral component of a total knee replacement (TKR). Patients. This series is a cohort of 21 patients who underwent 24 (3 bilateral) unicompartmental PFA replacements for isolated patellofemoral osteoarthritis. We have used the mobile bearing LCS PFA in all of them. There were 3 males and 18 females. Average age was 51(40-58) years. The Oxford Knee score was used to assess the results. Results. At the latest follow-up averaging 2.7 (0.5 to 4) years, 9 patients showed excellent improvement in their knee scores, 5 patients showed fair improvement and 7 patients very little. There were 9 revisions in 7 patients either due to mechanical problems or with persistent symptoms. We had 4 patients with mechanical complications who underwent revision and 4 patients had a conversion to TKR. The revision rate at 2 years was 33%. There were no infections or loosening of trochlear implants. Conclusion. The revision rate for this implant seems to be very high and mainly with the patellar implant (at the metal polyethylene interface). The Australian Orthopaedic association annual joint registry report 2008 reported a higher revision rate for the same implant at 5% from a pool of 1057 patients. The young active patient having a patellofemoral replacement may put extreme force on their patellar implant. We strongly advocate patellofemoral arthroplasties to be analysed separately from the unicompartmental knees in the National Joint Registries to highlight any persistent issues with this implant


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 922 - 928
1 Aug 2019
Garner A van Arkel RJ Cobb J

Aims. There has been a recent resurgence in interest in combined partial knee arthroplasty (PKA) as an alternative to total knee arthroplasty (TKA). The varied terminology used to describe these procedures leads to confusion and ambiguity in communication between surgeons, allied health professionals, and patients. A standardized classification system is required for patient safety, accurate clinical record-keeping, clear communication, correct coding for appropriate remuneration, and joint registry data collection. Materials and Methods. An advanced PubMed search was conducted, using medical subject headings (MeSH) to identify terms and abbreviations used to describe knee arthroplasty procedures. The search related to TKA, unicompartmental (UKA), patellofemoral (PFA), and combined PKA procedures. Surveys were conducted of orthopaedic surgeons, trainees, and biomechanical engineers, who were asked which of the descriptive terms and abbreviations identified from the literature search they found most intuitive and appropriate to describe each procedure. The results were used to determine a popular consensus. Results. Survey participants preferred “bi-unicondylar arthroplasty” (Bi-UKA) to describe ipsilateral medial and lateral unicompartmental arthroplasty; “medial bi-compartmental arthroplasty” (BCA-M) to describe ipsilateral medial unicompartmental arthroplasty with patellofemoral arthroplasty; “lateral bi-compartmental arthroplasty” (BCA-L) to describe ipsilateral lateral unicompartmental arthroplasty with patellofemoral arthroplasty; and tri-compartmental arthroplasty (TCA) to describe ipsilateral patellofemoral and medial and lateral unicompartmental arthroplasties. “Combined partial knee arthroplasty” (CPKA) was the favoured umbrella term. Conclusion. We recommend bi-unicondylar arthroplasty (Bi-UKA), medial bicompartmental arthroplasty (BCA-M), lateral bicompartmental arthroplasty (BCA-L), and tricompartmental arthroplasty (TCA) as the preferred terms to classify CPKA procedures. Cite this article: Bone Joint J 2019;101-B:922–928


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 89 - 89
1 Jul 2012
Bhattacharya R Scott C Morris H Wade F Nutton R
Full Access

Purpose. The aim of the present study was to look at survivorship and patient satisfaction of a fixed bearing unicompartmental knee arthroplasty with an all-polyethylene tibial component. Materials and Methods. We report the survivorship of 91 fixed bearing unicompartmental arthroplasties with all-polyethylene tibial components (Preservation DePuy UK), which were used for medial compartment osteoarthritis in 79 patients between 2004 and 2007. The satisfaction level of patients who had not undergone revision of the implant was also recorded. For comparison, we reviewed 49 mobile bearing unicompartmental arthroplasties (Oxford UKA Biomet UK Ltd), which had been used in 44 patients between 1998 and 2007. Results. Mean length of follow up of patients with the fixed bearing implant was 44.7 months (range 24 - 74 months) and for the mobile bearing replacement, the mean follow up was 67.6 months (24 - 119). In the fixed bearing design, at maximum follow up period of 74 months, 8 implants (8.8%) had been revised (or were listed for revision) to total knee replacement and in the mobile bearing design over the maximum follow up period of 119 months there had been only one revision (2.0%). Patients who had not undergone revision were asked if they were satisfied with their knee following the unicompartmental arthroplasty. In the fixed bearing design, 83.5% said that they were satisfied with the outcome of the operation compared to 93.9% of the patients receiving the mobile bearing design. Conclusion. We conclude that there is a higher incidence of revision of this fixed bearing design using an all-polyethylene tibial component compared to the mobile bearing design. We found that those patients who had not required revision had a lower rate of satisfaction with the fixed bearing compared to the mobile bearing design


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 88 - 88
1 Jul 2012
Davies AP
Full Access

The purpose of this paper was to investigate the predictability of outcome of a consecutive series of cemented unicompartmental or total knee replacements in a single surgeon series. Between September 2006 and February 2009, ninety-nine cemented, fixed bearing TKR were performed with patellar resurfacing. 52 cemented Miller Galante (Zimmer) Tibio-femoral UKR were performed in the same time interval. The minimum follow up was 6 months. Oxford and AKSS knee scores were collected prospectively at pre-operative and at routine follow up appointments. Pre-operative mean AKSS Knee score for TKR group was 33.9 and improved to 84.2 at 1 year. Mean scores for Tibiofemoral UKR were 40.4 improving to 84.3 at 1 year. Pre-operative mean Oxford knee score for TKR group was 34.6 (28%) and improved to 16.6 (65%) at 1 year. Mean scores for UKR were 28.5 (41%) improving to 14.0 (71%) at 1 year. These data would suggest that unicompartmental replacement performs as well as TKR. However, in the TKR group, 59% achieved a knee score >85 and 23% an Oxford score >80%. In the UKR group, 67% achieved knee score >85 and 45% an Oxford score >80%. Conversely, only 5% of TKR achieved knee score <50 and 20% Oxford score <50% whilst 10% of UKR had a knee score <50 and 26% and Oxford score <50%. These data show that whilst mean outcomes for TKR and UKR look similar, TKR offers a more predictable outcome with fewer clinical failures but also fewer excellent results. UKR offers a more polarised set of outcomes with far more clinically excellent results but also more clinical failures. These data can inform the ongoing debate regarding the role of unicompartmental arthroplasty. Patient selection is clearly critical but remains an inexact process


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 887 - 892
1 Jul 2006
Pandit H Beard DJ Jenkins C Kimstra Y Thomas NP Dodd CAF Murray DW

The options for treatment of the young active patient with isolated symptomatic osteoarthritis of the medial compartment and pre-existing deficiency of the anterior cruciate ligament are limited. The potential longevity of the implant and levels of activity of the patient may preclude total knee replacement, and tibial osteotomy and unicompartmental knee arthroplasty are unreliable because of the ligamentous instability. Unicompartmental knee arthroplasties tend to fail because of wear or tibial loosening resulting from eccentric loading. Therefore, we combined reconstruction of the anterior cruciate ligament with unicompartmental arthroplasty of the knee in 15 patients (ACLR group), and matched them with 15 patients who had undergone Oxford unicompartmental knee arthroplasty with an intact anterior cruciate ligament (ACLI group). The clinical and radiological data at a minimum of 2.5 years were compared for both groups. The groups were well matched for age, gender and length of follow-up and had no significant differences in their pre-operative scores. At the last follow-up, the mean outcome scores for both the ACLR and ACLI groups were high (Oxford knee scores of 46 (37 to 48) and 43 (38 to 46), respectively, objective Knee Society scores of 99 (95 to 100) and 94 (82 to 100), and functional Knee Society scores of 96 and 96 (both 85 to 100). One patient in the ACLR group needed revision to a total knee replacement because of infection. No patient in either group had radiological evidence of component loosening. The radiological study showed no difference in the pattern of tibial loading between the groups. The short-term clinical results of combined anterior cruciate ligament reconstruction and unicompartmental knee arthroplasty are excellent. The previous shortcomings of unicompartmental knee arthroplasty in the presence of deficiency of the anterior cruciate ligament appear to have been addressed with the combined procedure. This operation seems to be a viable treatment option for young active patients with symptomatic arthritis of the medial compartment, in whom the anterior cruciate ligament has been ruptured


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 5 - 5
1 Oct 2018
Gerow D Greco NJ Berend ME Berend KR Lombardi AV
Full Access

Intro/Purpose. Lateral partial knee replacement is indicated as an alternative to total knee replacement for isolated end stage lateral compartment degenerative joint disease. The purpose of this study is to report the surgical technique and clinical results of a large series of lateral partial knee replacements from two institutions. Methods. A retrospective review identified 205 lateral unicompartmental arthroplasty procedures performed in two practices over a six-year period (Aug 2011 – June 2017). Patients indicated for surgery met specific preoperative clinical and radiographic criteria confirming lateral compartment arthritic disease with a correctable deformity, intact full-thickness medial cartilage, competent anterior cruciate ligament, and minimal disease in the patellofemoral compartment. A single cemented fixed bearing tibial component design was used in all cases specifically designed for lateral compartment anatomy. Results. The average age was 65 years old and 76% were female. Average follow-up in the lateral partials was 1.7 years (range 0.5 years to 6 years). Knee Society Scores improved from 45 (pre-op) to 88 points (post-op). Range of motion improved from 6–115o (pre-op) to 0–122 o (post-op). No knees were revised to a TKA. One knee had an additional medial partial knee placed at 1.1 years post lateral partial knee replacement for medial disease progression. Two knees required an irrigation and debridement for traumatic wound dehiscence. Conclusion. This is the largest series of lateral partial knee replacements reported. Clinical improvements, range of motion, and survivorship were excellent at short-term follow-up. Long-term follow-up is needed for additional understanding of a novel implant designed specifically for the lateral compartment and the survivorship of the unreplaced compartments. We believe the lateral partial knee replacement to be a viable option for isolated lateral compartment disease in approximately 4% of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1488 - 1492
1 Nov 2005
Price AJ Dodd CAF Svard UGC Murray DW

We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the < 60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the ≥ 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford unicompartmental arthroplasty can achieve ten-year results that are comparable to total knee arthroplasty in patients < 60 years of age. We conclude that for patients aged over 50, age should not be considered a contraindication for this procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 44 - 48
1 Jan 2006
Keene G Simpson D Kalairajah Y

Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for unicompartmental arthroplasty. In each patient the planned alignment was the same for both knees. Overall, the mean planned post-operative alignment was to 2.3° of varus (0° to 5°). The side and starting order of surgery were randomised, using conventional instrumentation for one knee and computer-assisted surgery for the opposite side. The mean variation between the pre-operative plan and the achieved correction in the navigated and the non-navigated limb was 0.9° (. sd. 1.1; 0° to 4°) and 2.8° (. sd. 1.4; 1° to 7°), respectively. Using the Wilcoxon signed rank test, we found the difference in variation statistically significant (p < 0.001). Assessment of lower limb alignment in the non-navigated group revealed that 12 (60%) were within ± 2° of the pre-operative plan, compared to 17 (87%) of the navigated cases. Computer-assisted surgery significantly improves the post-operative alignment of medial unicompartmental knee arthroplasty compared to conventional techniques in patients undergoing bilateral simultaneous arthroplasty. Improved alignment after arthroplasty is associated with better function and increased longevity


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 786 - 792
1 Jun 2015
Hutt JRB Farhadnia P Massé V Lavigne M Vendittoli P

This randomised trial evaluated the outcome of a single design of unicompartmental arthroplasty of the knee (UKA) with either a cemented all-polyethylene or a metal-backed modular tibial component. A total of 63 knees in 45 patients (17 male, 28 female) were included, 27 in the all-polyethylene group and 36 in the metal-backed group. The mean age was 57.9 years (39.6 to 76.9). At a mean follow-up of 6.4 years (5 to 9.9), 11 all-polyethylene components (41%) were revised (at a mean of 5.8 years; 1.4 to 8.0) post-operatively and two metal-backed components were revised (at one and five years). One revision in both groups was for unexplained pain, one in the metal-backed group was for progression of osteoarthritis. The others in the all-polyethylene group were for aseptic loosening. The survivorship at seven years calculated by the Kaplan–Meier method for the all-polyethylene group was 56.5% (95% CI 31.9 to 75.2, number at risk 7) and for the metal-backed group was 93.8% (95% CI 77.3 to 98.4, number at risk 16) This difference was statistically significant (p <  0.001). At the most recent follow-up, significantly better mean Western Ontario and McMaster Universities Arthritis Index Scores were found in the all-polyethylene group (13.4 vs 23.0, p = 0.03) but there was no difference in the mean Knee injury and Osteoarthritis Outcome scores (68.8; 41.4 to 99.0 vs 62.6; 24.0 to 100.0), p = 0.36). There were no significant differences for range of movement (p = 0.36) or satisfaction (p = 0.23). This randomised study demonstrates that all-polyethylene components in this design of fixed bearing UKA had unsatisfactory results with significantly higher rates of failure before ten years compared with the metal-back components. Cite this article: Bone Joint J 2015;97-B:786–92


Bone & Joint Open
Vol. 4, Issue 12 | Pages 948 - 956
15 Dec 2023
Vella-Baldacchino M Webb J Selvarajah B Chatha S Davies A Cobb JP Liddle AD

Aims

With up to 40% of patients having patellofemoral joint osteoarthritis (PFJ OA), the two arthroplasty options are to replace solely the patellofemoral joint via patellofemoral arthroplasty (PFA), or the entire knee via total knee arthroplasty (TKA). The aim of this study was to assess postoperative success of second-generation PFAs compared to TKAs for patients treated for PFJ OA using patient-reported outcome measures (PROMs) and domains deemed important by patients following a patient and public involvement meeting.

Methods

MEDLINE, EMBASE via OVID, CINAHL, and EBSCO were searched from inception to January 2022. Any study addressing surgical treatment of primary patellofemoral joint OA using second generation PFA and TKA in patients aged above 18 years with follow-up data of 30 days were included. Studies relating to OA secondary to trauma were excluded. ROB-2 and ROBINS-I bias tools were used.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims

The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients.

Methods

All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m2 (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1591 - 1595
1 Dec 2006
Price AJ Oppold PT Murray DW Zavatsky AB

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces. The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1126 - 1130
1 Nov 2002
Ashraf T Newman JH Evans RL Ackroyd CE

We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis. At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period. We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%. Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable unicompartmental replacement for isolated lateral compartment osteoarthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 71 - 71
1 Jul 2012
Beard D Holt M Mullins M Massa E Malek S Price A
Full Access

Purpose. Late stage medial unicompartmental osteoarthritic disease of the knee can be treated by either Total Knee Replacement (TKR) or Unicompartmental Replacement (UKR). As a precursor to the TOPKAT study this work tested the postulate that individual surgeons show high variation in the choice of treatment for individual patients. Method. Four surgeons representing four different levels of expertise or familiarity with partial knee replacement (UKR design centre knee surgeon, specialist knee surgeon, arthroplasty surgeon and a year six trainee) made a forced choice decision of whether they would perform a TKR or UKR based on the same pre-operative radiographic and clinical data in 140 individual patients. Consistency of decision was also evaluated for each surgeon 3 months later and the effect of additional clinical data was also evaluated. The sample consisted of the 100 patients who had subsequently undergone UKR and 40 who had undergone TKR. Results. The specialist knee surgeon from the design centre would have performed UKR in 80% of the patients. The other surgeons would have performed a UKR in between 32-43% of the patients representing a variation in decision making of up to 59%. The choice of treatment for each surgeon remained unchanged in between 80-87% of cases after viewing additional clinical data. There was high intra surgeon repeatability in decision making when assessed 3 months later. Conclusion. Despite being given identical information, surgeons show high variability in decision making for patients with medial OA of the knee. A knee surgeon with a special interest in partial knee replacement is twice as likely to choose UKR for a patient with medial compartment OA than a non specialist surgeon. The choice is predominantly based on radiological findings but decision making for each individual surgeon is reassuringly consistent. The implications are that if TKR and UKR have unequal efficacy, some patients may be undergoing a suboptimal procedure