The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs). A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints.Aims
Methods
Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or
Aims. Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. Methods. Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. Results. In the overall group, only fixation was significantly associated with migration (p < 0.001). For
We studied the effect of a metal tray with an intramedullary stem on the micromotion of the tibial component in total knee arthroplasty. Of 32 uncemented Freeman-Samuelson knee arthroplasties performed in London and Gothenburg, nine had a metal backing and stem added to the tibial component. Micromotion of the tibial components, expressed as migration and inducible displacement, was analysed using roentgen stereophotogrammetric analysis up to two years follow-up. The addition of a metal back and a 110 mm stem to the standard polyethylene component significantly reduced both migration over two years and inducible displacement.
The purpose of this study was to evaluate a high flex porous tantalum metal monoblock component system implanted through a MIS technique. A fellowship trained surgeon proficient in MIS surgery performed 109 consecutive TKAs in 95 patients. Patients were implanted with a tantalum monoblock tibia and a fiber-metal cruciate-retaining high flex femur through a MIS midvastus approach. Ninety uncemented porous tantulum monoblock patellae and 19 cemented all polyethylene patellae were implanted. Knee Society scores and Knee Society radiographic scores were calculated in all patients. Follow-up for a minimum of 2 years was performed in 109 knees. The average follow up was 39 months. Sixty-six percent of the patients were female and 34% male. The average age was 66 years. The average preoperative Knee Society Knee score was 36. The average preop Knee Society Functional Score was 46. Osteoarthritis was the primary diagnosis in 104 knees. Rheumatoid arthritis and Hemophilia was the diagnosis in two knees each. The average Knee Society Knee Score improved to 89. The average Knee Society Function score improved to 86. 106 of the knees were rated good or excellent and three knees were rated poor. Two patellar revisions were performed for loose components and one for patellar misalignment. One patella fracture occurred that required ORIF. One femoral component was revised for loosening. There were nonprogressive radiographic lucencies demonstrated on 4 tibial components. One tibial component was rated loose. There were radiographic lucencies on 5 femoral components, all nonprogressive. There were two uncemented tantalum patellar components with stable radiolucencies. Early results in 109 consecutive porous tantalum metal tibial and high flex cruciate-retaining femoral components implanted through an MIS midvastus approach have a high rate of success at a minimum followup of two years.
Bone mineral density (BMD) and bone mineral content (BMC) have not been previously assessed in unicompartmental knee replacement (UKR). We studied the early bone changes beneath the uncemented Oxford medial UKR. Our hypothesis was that this implant should decrease the shear stresses across the bone-implant interface and result in improved BMD and BMC beneath the tibial component. Using the Lunar iDXA and knee specific software we developed 7 regions of interest (ROI) in the proximal tibia and assessed 38 patients with an uncemented Oxford UKR at 2 years. We measured the replaced knee and contralateral unreplaced knee using the same ROI and compared the BMD and BMC. The initial precision study in 20 patients demonstrated high precision in all areas. There were 12 males and 16 females with an average age of 65.8 years (46–84 years). ROI 1 and 2 were beneath the tibial tray and had significantly less BMC (p=0.023 and 0.001) and BMD (p=0.012 and 0.002). ROI 3 was the lateral tibial plateau and this area also had significantly less BMC (p=0.007) and BMD (p=0.0001). ROI 4 and 5 immediately below the tibial keel had no significant change. These changes were independent of gender and age. These results were surprising in that the universal loss of BMC and BMD suggested that bone loading of the proximal tibia was not improved even after a UKR. The better BMD and BMC adjacent to the keel confirms other studies that show improved bone in-growth around keels and pegs in the
Aims: To prospectively study the optimum fixation of the tibial component in patients younger than 65 years, where the mode of fixation is randomized. Methods: 35 patients (mean age 56 years, range 29 to 64) were operated with the Profix (Smith&
Nephew) TKA due to gonarthrosis grade III to V. The patients were randomly allocated to fixation of the tibial component with cement (Group C) (n=6), uncemented fixation with hydroxyapatite coating (HA) without screws (Group HA−) (n=14), or uncemented fixation with HA coating and with screws (Group HA+) (n=15). Radiostereometry (RSA) was performed postop., 3, 12 and 24 months postop. Results: There were no complications or revisions during the follow-up. Up to 3 months the cemented implants migrated the least and the HA- group the most (P = 0.009 – 0.036). From 3 to 24 months however, the implants in all three groups displayed very small migration, magnitudes well below the detection limit of RSA, and there were no differences between the three groups. Conclusions: The
Purpose: To investigate the effect that gender may have on the RSA defined migration pattern of cemented and
Purpose: To investigate the association between pre-operative gait patterns and the RSA defined migration migration pattern of cemented and
Initial fixation affects ingrowth of
Introduction Cemented fixation of the tibial component is the standard treatment for patients older than 65 with long-standing excellent results. Whether cemented fixation is best even for younger patients is still debated, and if uncemented fixation is chosen, the question remains as to whether screws are necessary as an adjunct. We present the results of a prospective randomized study comparing cemented and two modes of uncemented fixation. Methods Thirty-five patients (mean age 56 years, range 29 to 64) were operated with the Profix (Smith&
Nephew) TKA for gonarthrosis grade III to V. At the operation, the patients were randomly allocated to fixation of the tibial component with cement (Group C, n=6), uncemented fixation with hydroxyapatite (HA) coating without screws (Group HA, n=14), or uncemented fixation with HA coating and with screws (Group HA+, n=15). The implants and tibiae were prepared for RSA with tantalum markers. RSA was performed post-operatively, three, 12 and 24 months post-op. Results There were no complications or revisions during the follow-up. For all three types of fixation the migration was larger during the initial three months, after which the migration leveled off. At three months, subsidence and tilting of the implant was significantly larger for group HA- compared to group C (P = 0.009 − 0.036), with the migration for group HA+ in between. This difference between the groups persisted up to 24 months. When examining the migration from three to 24 months, the implants in all three groups displayed very small migration, magnitudes well below the detection limit of RSA. There were no differences in magnitude of migration between the three groups between three and 24 months. Conclusions The
Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed.Aims
Methods
Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up.Aims
Methods
Aseptic loosening is a leading cause of uncemented arthroplasty failure, often accompanied by fibrotic tissue at the bone-implant interface. A biological target, neutrophil extracellular traps (NETs), was investigated as a crucial connection between the innate immune system’s response to injury, fibrotic tissue development, and proper bone healing. Prevalence of NETs in peri-implant fibrotic tissue from aseptic loosening patients was assessed. A murine model of osseointegration failure was used to test the hypothesis that inhibition (through Patient peri-implant fibrotic tissue was analyzed for NETs biomarkers. To enhance osseointegration in loose implant conditions, an innate immune system pathway (NETs) was either inhibited (Aims
Methods
We report our results in 24 children with malignant primary bone tumours of the distal femur treated with a Stanmore extendible endoprosthesis (SEER). This consists of a femoral component that can be lengthened, a constrained knee and an
For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization.Aims
Methods
Introduction. Initial stability of the tibial component influences the success of uncemented total knee arthroplasty. In uncemented components, osseointegration provides long-term fixation which is particularly important for the tibial component. Osseointegration is facilitated by minimising bone-implant interface micromotion to within acceptable limits. To investigate initial stability, this study compares the micromotion and initial seating of two
The primary aim of the study was to compare the knee-specific functional outcome of robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty (mTKA) for the management of isolated medial compartment osteoarthritis. Secondary aims were to compare length of hospital stay, general health improvement, and satisfaction between rUKA and mTKA. A powered (1:3 ratio) cohort study was performed. A total of 30 patients undergoing rUKA were propensity score matched to 90 patients undergoing mTKA for isolated medial compartment arthritis. Patients were matched for age, sex, body mass index (BMI), and preoperative function. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were collected preoperatively and six months postoperatively. The Forgotten Joint Score (FJS) and patient satisfaction were collected six months postoperatively. Length of hospital stay was also recorded.Aims
Methods
Hydroxyapatite coatings for uncemented fixation in total knee
arthroplasty can theoretically provide a long-lasting biological
interface with the host bone. The objective of this study was to
test this hypothesis with propriety hydroxyapatite, peri-apatite,
coated tibial components using component migration measured with radiostereometric
analysis over two years as an indicator of long-term fixation. A total of 29 patients at two centres received uncemented PA-coated
tibial components and were followed for two years with radiostereometric
analysis exams to quantify the migration of the component.Aims
Patients and Methods
Total knee arthroplasty (TKA) is a cost effective
and extremely successful operation. As longevity increases, the demand
for primary TKA will continue to rise. The success and survivorship
of TKAs are dependent on the demographics of the patient, surgical
technique and implant-related factors. Currently the risk of failure of a TKA requiring revision surgery
ten years post-operatively is 5%. The most common indications for revision include aseptic loosening
(29.8%), infection (14.8%), and pain (9.5%). Revision surgery poses
considerable clinical burdens on patients and financial burdens
on healthcare systems. We present a current concepts review on the epidemiology of failed
TKAs using data from worldwide National Joint Registries. Cite this article: