Advertisement for orthosearch.org.uk
Results 1 - 20 of 56
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 613 - 617
1 Jul 1991
O'Driscoll S Horii E Carmichael S Morrey B

The anatomy of the cubital tunnel and its relationship to ulnar nerve compression is not well documented. In 27 cadaver elbows the proximal edge of the roof of the cubital tunnel was formed by a fibrous band that we call the cubital tunnel retinaculum (CTR). The band is about 4 mm wide, extending from the medial epicondyle to the olecranon, and perpendicular to the flexor carpi ulnaris aponeurosis. Variations in the CTR were classified into four types. In type 0 (n = 1) the CTR was absent. In type Ia (n = 17), the retinaculum was lax in extension and taut in full flexion. In type Ib (n = 6) it was tight in positions short of full flexion (90 degrees to 120 degrees). In type II (n = 3) it was replaced by a muscle, the anconeus epitrochlearis. The CTR appears to be a remnant of the anconeus epitrochlearis muscle and its function is to hold the ulnar nerve in position. Variations in the anatomy of the CTR may explain certain types of ulnar neuropathy. Its absence (type 0 CTR) permits ulnar nerve displacement. Type Ia is normal and does not cause ulnar neuropathy. Type Ib can cause dynamic nerve compression with elbow flexion. Type II may be associated with static compression due to the bulk of the anconeus epitrochlearis muscle


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 823 - 827
1 Jun 2010
Gong HS Chung MS Kang ES Oh JH Lee YH Baek GH

The outcome of surgery in patients with medial epicondylitis of the elbow is less favourable in those with co-existent symptoms from the ulnar nerve. We wanted to know whether we could successfully treat such patients by using musculofascial lengthening of the flexor-pronator origin with simultaneous deep transposition of the ulnar nerve. We retrospectively reviewed 19 patients who were treated in this way. Seven had grade I and 12 had grade IIa ulnar neuropathy. At a mean follow-up of 38 months (24 to 48), the mean visual analogue scale pain scores improved from 3.7 to 0.3 at rest, from 6.6 to 2.1 with activities of daily living, and from 7.9 to 2.3 at work or sports, and the mean disabilities of the arm, shoulder and hand scores improved from 42.2 to 23.5. These results suggest that this technique can be effective in treating patients with medial epicondylitis and coexistent ulnar nerve symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 777 - 779
1 Sep 1996
Geutjens GG Langstaff RJ Smith NJ Jefferson D Howell CJ Barton NJ

We carried out a prospective randomised study comparing medial epicondylectomy with anterior transposition for the treatment of ulnar neuropathy at the elbow. The mean follow-up period was 4.5 years and we assessed the patients neurologically and orthopaedically. Neither procedure appeared to have a significant effect on elbow function. Our study showed better results after medial epicondylectomy; in particular patient satisfaction was higher than after ulnar nerve transposition. There were no significant differences in motor power or nerve-conduction rates and sensory fibres appeared to be more vulnerable to devascularisation


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 390 - 393
1 May 1997
Tsujino A Itoh Y Hayashi K Uzawa M

We operated on 16 patients for ulnar neuropathy associated with osteoarthritis of the elbow. They were all male manual workers, with an average age of 51 years at the time of surgery. The severity of the symptoms was McGowan grade 1 in five patients, grade 2 in nine and grade 3 in two. The mean follow-up was 36 months. The operation consists of resecting the osteophytes around the postcondylar groove. The shallow and narrow cubital tunnel is made deep and wide and the ulnar nerve is replaced with its surrounding soft tissues in the enlarged groove. All patients were relieved of discomfort and all showed some improvement or full recovery of motor and sensory function. The ulnar nerve showed no evidence of irritation or adhesion. This procedure also allows early movement of the elbow after operation, because the subcutaneous tissues and muscles have not been detached


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims. There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). Methods. We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal. Results. The mean MEPS significantly improved from 47 (15 to 70) points preoperatively to 95 (70 to 100) points at final follow-up (p < 0.001). Complications were noted in six elbows (23%) in six patients, and of these, four with an ulnar neuropathy and one elbow with postoperative traumatic fracture required additional surgeries. There was no revision with implant removal, and there was no radiological evidence of loosening around the components. With any revision surgery as the endpoint, the survival rates up to 25 years were 78.1% (95% confidence interval 52.8 to 90.6) as determined by Kaplan-Meier analysis. Conclusion. The clinical outcome of primary unlinked TEA for young patients with RA was satisfactory and comparable with that for elderly patients. A favourable survival rate without implant removal might support the use of unlinked devices for young patients with this disease entity, with a caution of a relatively high complication rate regarding ulnar neuropathy. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Jt Open 2023;4(1):19–26


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 212 - 218
1 Feb 2024
Liu S Su Y

Aims. Medial humeral epicondyle fractures (MHEFs) are common elbow fractures in children. Open reduction should be performed in patients with MHEF who have entrapped intra-articular fragments as well as displacement. However, following open reduction, transposition of the ulnar nerve is disputed. The aim of this study is to evaluate the need for ulnar nerve exploration and transposition. Methods. This was a retrospective cohort study. The clinical data of patients who underwent surgical treatment of MHEF in our hospital from January 2015 to January 2022 were collected. The patients were allocated to either transposition or non-transposition groups. Data for sex, age, cause of fracture, duration of follow-up, Papavasiliou and Crawford classification, injury-to-surgery time, preoperative ulnar nerve symptoms, intraoperative exploration of ulnar nerve injury, surgical incision length, intraoperative blood loss, postoperative ulnar nerve symptoms, complications, persistent ulnar neuropathy, and elbow joint function were analyzed. Binary logistic regression analysis was used for statistical analysis. Results. A total of 124 patients were followed up, 50 in the ulnar nerve transposition group and 74 in the non-transposition group. There were significant differences in ulnar nerve injury (p = 0.009), incision length (p < 0.001), and blood loss (p = 0.003) between the two groups. Binary logistic regression analysis revealed that preoperative ulnar nerve symptoms (p = 0.012) were risk factors for postoperative ulnar nerve symptoms. In addition, ulnar nerve transposition did not affect the occurrence of postoperative ulnar nerve symptoms (p = 0.468). Conclusion. Ulnar nerve transposition did not improve clinical outcomes. It is recommended that the ulnar nerve should not be transposed when treating MHEF operatively. Cite this article: Bone Joint J 2024;106-B(2):212–218


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 2 | Pages 225 - 227
1 May 1978
Murakami Y Komiyama Y


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1348 - 1351
1 Oct 2008
Rispoli DM Athwal GS Morrey BF

Ulnar neuropathy presents as a complication in 5% to 10% of total elbow replacements, but subsequent ulnar neurolysis is rarely performed. Little information is available on the surgical management of persistent ulnar neuropathy after elbow replacement. We describe our experience with the surgical management of this problem. Of 1607 total elbow replacements performed at our institution between January 1969 and December 2004, eight patients (0.5%) had a further operation for persistent or progressive ulnar neuropathy. At a mean follow-up of 9.2 years (3.1 to 21.7) six were clinically improved and satisfied with their outcome, although, only four had complete recovery. When transposition was performed on a previously untransposed nerve the rate of recovery was 75%, but this was reduced to 25% if the nerve had been transposed at the time of the replacement


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1489 - 1497
1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims. The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications. Materials and Methods. We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy). Results. This study included a total of 679 TEAs for RA (n = 482) or post-traumatic conditions (n = 197). After exclusion, all of the TEAs included in this meta-analysis were cemented with linked components. Our analysis demonstrated that the RA group was associated with a higher risk of septic loosening after TEA (odds ratio (OR) 3.96, 95% confidence interval (CI) 1.11 to 14.12), while there was an increased risk of bushing wear, axle failure, component disassembly, or component fracture in the post-traumatic group (OR 4.72, 95% CI 2.37 to 9.35). A higher MEPS (standardized mean difference 0.634, 95% CI 0.379 to 0.890) was found in the RA group. There were no significant differences in arc of range of movement, DASH questionnaire, and risk of aseptic loosening, deep infection, perioperative fracture, or ulnar neuropathy. Conclusion. The aetiology of TEA surgery appears to have an impact on the outcome in terms of specific modes of implant failures. RA patients might have a better functional outcome after TEA surgery. Cite this article: Bone Joint J 2019;101-B:1489–1497


Bone & Joint 360
Vol. 4, Issue 1 | Pages 32 - 33
1 Feb 2015

The February 2015 Research Roundup360 looks at: Markers of post-traumatic ankle arthritis; Mangoes, trees and Solomon Islanders; Corticosteroid injection and ulnar neuropathy; Moral decision-making: the secret skill?; Biomechanical studies under the spotlight; Anaesthetic risk and hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1129 - 1134
1 Nov 2000
Rozing P

We have reviewed 66 consecutive Souter-Strathclyde arthroplasties of the elbow implanted in 59 patients between 1982 and 1993. Thirteen patients (15 elbows) (19.6%) died. Sixteen elbows (24.2%) were revised, six for aseptic loosening (9%), four (6%) because of fracture or loosening after a fracture, three (4.5%) for infection and three (4.5%) for dislocation. Four patients refused to attend for review. In 33 elbows with a follow-up of 93 months (60 to 167) complete relief of pain was achieved in 22 (67%) when seen at one year. After ten years or more 36% of the elbows were painfree and 64% had occasional slight pain especially under loading or stress. The mean gain in the arc of movement was 16°, but a mean flexion contracture of 33° remained. The main early complications were intraoperative fractures of the epicondyles (9%), postoperative dislocation (4.5%) and ulnar neuropathy. The incidence of ulnar neuropathy before operation was 19%. After operation 20 patients (33%) had an ulnar neuropathy, in seven of which it had been present before operation, and of these weakness of the hypothenar muscle occurred in two. The probability of survival of the Souter-Strathclyde elbow prosthesis based on the Kaplan-Meier calculation is 69% at ten years


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims. The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA). Patients and Methods. We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis. Results. The mean MEPI scores significantly improved from 40 (10 to 75) points preoperatively to 95 (30 to 100) points at final follow-up (p < 0.0001). Complications were noted in ten elbows (ten patients; 11%). Two had an intraoperative humeral fracture which was treated by fixation and united. One had a postoperative fracture of the olecranon which united with conservative treatment and one had a radial neuropathy which resolved. Further surgery was required for one with a dislocation, three with an ulnar neuropathy and one with a postoperative humeral fracture. Revision with removal of the components was performed in one elbow due to deep infection. There was no radiographic evidence of loosening around the components.With any revision surgery or revision with implant removal as the endpoint, the rates of survival up to 14 years were 93% (95% confidence interval (CI), 83.9 to 96.6) and 99% (95% CI 91.9 to 99.8), respectively, as determined by Kaplan-Meier analysis. Conclusion. With the appropriate indications, the mid-term clinical performance of the cemented JACE TEA is reliable and comparable to other established TEAs in the management of the elbow in patients with RA. Cite this article: Bone Joint J 2018;100-B:1066–73


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 273 - 273
1 Jul 2014
Alizadehkhaiyat O Vishwanathan K Frostick S
Full Access

Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2), ulnar neuropathy (N=3), pre-prosthetic fracture (N=2), and prosthetic failure (N=1). Discussion. TER using the Discovery Elbow System is an effective arthroplasty in terms of functional improvement, pain relief and range of motion in both primary and revision patients. TER resulted in no/mild pain in 78% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 20° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSBIII (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 25° in pronation-supination arc in our series is also comparable to that of 21–28° reported the Coonrad-Morrey and 27–33° for Discovery prostheses. An infection rate of 2% is lower than several other reports for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy (3%) was lower compared to GSBIII TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%)


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 256 - 256
1 Nov 2002
Tsujino A Ochiai N Itoh Y Tanaka T Nishiura Y
Full Access

We performed a new operation for ulnar neuropathy caused by recurrent dislocation at the medial epicondyle. There were eleven patients, eight men and three women, with an average age of 52 years (24–74 years) at the time of surgery. The mean duration of symptoms was 23 months. The severity of the symptoms was McGowan grade 1 in five patients, grade 2 in five patients, and grade 3 in one patient. The operation consisted of ulnar groove plasty proximal to the cubital tunnel. The ulnar nerve was replaced into this reconstructed groove. The nerve was confirmed to be stable throughout the full range of elbow motion. The cubital tunnel retinaculum of all patients was hypoplastic and the dislocated portion of the ulnar nerves was hard. One nerve showed severe adhesion around the dislocation site. One patient had a pseudo-neuroma. All patients were relieved of discomfort, and motor and sensory function were recovered. The ulnar nerve in the groove showed neither irritation nor adhesion. In patients with grade 1, symptoms or numbness of the fingers was relieved within three months of the operation. Sensory disturbances in patients with grade 2 symptoms also improved within six months. Grade 2 patients with intrinsic muscle weakness regained normal muscular power, and these with patients with intrinsic muscle atrophy had showed increasing muscular power. The patient with grade 3 symptomes recovered normal sensation after 1 year; clawing of the ring and little fin-gers recovered, and the muscle volume was increased. Friction ulnar neuropathy has been treated traditionally by anterior transpositon or medial epicondylectomy. The ulnar nerve may become entrapped in scar tissue after these operations. We believe that this anatomical position is optimum for the nerve and that this procedure is essential for treatment of friction neuropathy


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 2 - 2
1 Mar 2013
Alizadehkhaiyat O Vishwanathan K Frostick S Al Mandhari A
Full Access

Background. The quest for the perfectly designed elbow prosthesis continues as instability and loosening remain the foremost reasons for the failure of total elbow replacement (TER). The Discovery® Elbow System (Biomet, UK) (Figure 1), which has been used in UK since 2003, is one of the latest generations of linked prosthesis. This system was designed to decrease polyethylene-bushing wear, improve anatomic stem design, restore elbow joint biomechanics, and produce a hinge that could be easily revised. This report describes the short term outcome of TER using the Discovery® Elbow System. Patients and Methods. A total of 60 TERs including 48 primary and 12 revisions were performed between 2003 and 2008. Patients included 21 males (37%) and 36 females (63%) with a mean age of 63 years. The indications for primary TER were advanced rheumatoid arthritis (n=19), osteoarthritis (n=16), post traumatic osteoarthritis (n=9), acute fractures (n=3), and haemophilic arthropathy (n=1). The outcome was assessed using pain score, Liverpool Elbow Score (LES), and range of movement during a mean follow-up of 26 months. Associated complications were documented. Radiological assessment included evaluation for loosening, instability and periprosthetic fractures. Results. The mean LES was significantly (p<0.001) improved from 3.8 (±1) pre-operatively to 6.9 (±2) at the final follow- up. Significant improvements were noted in elbow flexion from 100° (±22) to 120° (±15), supination from 41° (±28) to 65° (±20) and pronation from 52° (±22) to 72° (±18). There was no significant change in elbow extension. Mean improvement in flexion-extension and pronation-supination arc was 22° and 44°, respectively. 46 cases (77%) were completely pain-free at the final follow-up. The main complications included deep infection (4 cases – treated with staged revision TER), postoperative ulnar neuropathy (3 cases–treated with decompression), intra-operative fractures of medial condyle (3 cases – treated non-operatively with brace), and elbow haemarthrosis (1 case). Discussion. TER with Discovery® Elbow System resulted in either no pain or mild pain in 87% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 22° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSB III (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 44° in pronation-supination arc in our series is also comparable to that of 31–67° reported for GSB III and higher than the Coonrad-Morrey prosthesis (21–28°). In terms of complications, an infection rate of 6.7% is consistent with those reported for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy was lower compared to GSB III TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%). While the survival of Discovery TER was 93%, the survival of GSB III (5–6 years) and Coonrad-Morrey (5 years) has been reported as 71–85% and 72–90%. The results indicate that Discovery® Elbow System is an effective device for total elbow arthroplasty in terms of functional improvement, pain relief and range of motion at short-term follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function. No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%)


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 668 - 671
1 May 2010
Naqui SZ Rajpura A Nuttall D Prasad P Trail IA

This is a retrospective review of the results of the Acclaim total elbow replacement in 11 older patients aged ≥ 65 years with primary osteoarthritis of the elbow, with a mean follow-up of 57.6 months (30 to 86.4). Significant reductions in pain and improvement in range of movement and function were recorded. Radiological review revealed two patients with 1 mm lucencies in a single zone, and one patient with 1 mm lucencies in two zones. No components required revision. There were no deep infections, dislocations or mechanical failures. Complications included one intra-operative medial condylar fracture and one post-operative transient ulnar neuropathy, which resolved. This study demonstrates that the Acclaim prosthesis provides good symptomatic relief and improvement of function in patients with primary osteoarthritis, with low rates of loosening or other complications. This prosthesis can therefore be considered for patients aged ≥ 65 years with primary osteoarthritis of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 234 - 239
1 Mar 1998
Kudo H

Six highly unstable elbows with severe bone loss due to rheumatoid arthritis were replaced by a non-constrained, unlinked prosthesis. Bone defects were filled with autogenous bone grafts. The mean follow-up was 4.5 years (2 to 8). The clinical results were excellent in four elbows and good in two, with good varus-valgus stability in all. Radiological follow-up showed no appreciable signs of loosening, and the bone grafts had retained most of their original size, with minimal resorption. There were no major complications such as dislocation, skin necrosis, infection or ulnar neuropathy. The study has shown that the so-called mutilans elbow can be successfully replaced using a properly selected type of non-constrained, unlinked prosthesis with bone grafting of the major defects


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 56 - 57
1 Feb 1978
Dreyfuss U Kessler I

Two cases of unusual snapping at the elbow are described. In both, the medial head of the triceps was found to be separated from the main muscle belly. During flexion of the elbow, the medial head dislocated over the medial epicondyle, producing a characteristic snapping phenomenon. Both cases were of long standing and had been asymptomatic for years. The first clinical symptoms were those of an ulnar neuropathy. In order to restore the normal position of the medial head of the triceps, its tendon was detached from the olecranon, passed under the central tendon and interlaced to it. The ulnar nerve was left in the epicondylar groove in one case and transposed anteriorly in the other. At the end of the procedure flexion of the elbow was unobstructed and the snapping phenomenon had disappeared


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 339 - 340
1 Jul 2011
Mitsionis G Manoudis G Paschos N Lykissas M Korompilias A Beris A
Full Access

The purpose of this study is to evaluate the long-term results of the surgical treatment of cubital tunnel syndrome by comparing the in-situ decompression and release of the ulnar nerve with or without partial medial epicondylectomy and the anterior transposition and release respectively. Material and Method: From 1991 since 2008, 119 patients, (81 men and 38 women) with an average age of 51(13–72 years) years were treated surgically for ulnar nerve compression at the elbow. The average duration of symptoms before surgery was 15 months (2–48 months). Preoperatively 2 patients were grade I, 52 patients were grade IIA, 31 patients were IIB and 34 were grade III according to the modified McGowan score. We performed in-situ decompression of the ulnar nerve in 35 patients, release with partial medial epicon-dylectomy in 44 patients and release with anterior transposition of the nerve in 40 patients. 17 patients were lost to follow-up. 108 patients were clinically assessed. Comparing the results among different surgical procedures, an improvement of at least one McGowan grade was obtained in 26 of 30 patients treated with simple decompression, in 29 of 35 patients treated with release and anterior transposition of the nerve and in 38 of 43 patients treated with release and medial epicondylectomy. The results of this study show that the possibility for complete recovery is inversely related to the initial neuropathy grade. Partial medial epicondylectomy is a valuable surgical procedure for treating grade I to IIB ulnar neuropathy because is an anatomic method with minimal nerve manipulation preserving regional blood supply