Advertisement for orthosearch.org.uk
Results 1 - 20 of 348
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims. The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. Methods. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients. Results. Preparation of the prosthesis was a mean of 8.0 days (SD 1.5), during which time no patients experienced tumour progression. The mean operating time and intraoperative blood loss were 158.1 minutes (SD 67.6) and 176.9 ml (SD 187.8), respectively. All of the prostheses were implanted successfully. During a mean follow-up of 25.7 months (SD 7.8), no patients died, but four had complications (two superficial wound problems, one temporary palsy of radial nerve, and one dislocation). No aseptic loosening, structural failure, infection, heterotopic ossification, or degenerative arthritis was seen in this study. The mean flexion of the elbow was 119.6° (SD 15.9°) and the mean extension lag was 11.9° (SD 13.8°). The mean Musculoskeletal Tumor Society 93 score and Mayo Elbow Performance Score were 28.4 (SD 0.9) and 97.7 (SD 4.4), respectively. Conclusion. The custom-made, 3D-printed megaprosthesis with hemiarthroplasty is a feasible option for functional reconstruction after resection of a tumour in the distal humerus or proximal ulna. Cite this article: Bone Joint J 2022;104-B(6):747–757


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1180 - 1188
1 Oct 2022
Qu H Mou H Wang K Tao H Huang X Yan X Lin N Ye Z

Aims. Dislocation of the hip remains a major complication after periacetabular tumour resection and endoprosthetic reconstruction. The position of the acetabular component is an important modifiable factor for surgeons in determining the risk of postoperative dislocation. We investigated the significance of horizontal, vertical, and sagittal displacement of the hip centre of rotation (COR) on postoperative dislocation using a CT-based 3D model, as well as other potential risk factors for dislocation. Methods. A total of 122 patients who underwent reconstruction following resection of periacetabular tumour between January 2011 and January 2020 were studied. The risk factors for dislocation were investigated with univariate and multivariate logistic regression analysis on patient-specific, resection-specific, and reconstruction-specific variables. Results. The dislocation rate was 13.9% (n = 17). The hip COR was found to be significantly shifted anteriorly and inferiorly in most patients in the dislocation group compared with the non-dislocation group. Three independent risk factors were found to be related to dislocation: resection of gluteus medius (odds ratio (OR) 3.68 (95% confidence interval (CI) 1.24 to 19.70); p = 0.039), vertical shift of COR > 18 mm (OR 24.8 (95% CI 6.23 to 128.00); p = 0.001), and sagittal shift of COR > 20 mm (OR 6.22 (95% CI 1.33 to 32.2); p = 0.026). Conclusion. Among the 17 patients who dislocated, 70.3% (n = 12) were anterior dislocations. Three independent risk factors were identified, suggesting the importance of proper restoration of the COR and the role of the gluteus medius in maintaining hip joint stability. Cite this article: Bone Joint J 2022;104-B(10):1180–1188


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1168 - 1173
1 Oct 2022
Gazendam AM Schneider P Vélez R Ghert M

Aims

The aim of this study was to determine the prevalence and impact of tourniquet use in patients undergoing limb salvage surgery with endoprosthetic reconstruction for a tumour around the knee.

Methods

We retrieved data from the Prophylactic Antibiotic Regimens in Tumor Surgery (PARITY) trial; specifically, differences in baseline characteristics, surgical details, and postoperative functional outcomes between patients who had undergone surgery under tourniquet and those who had not. A linear regression model was created to evaluate the impact of tourniquet use on postoperative Toronto Extremity Salvage Scores (TESSs) while controlling for confounding variables. A negative-binomial regression model was constructed to explore predictors of postoperative length of stay (LOS).


Bone & Joint Open
Vol. 4, Issue 6 | Pages 442 - 446
12 Jun 2023
Toda Y Iwata S Kobayashi E Ogura K Osaki S Fukushima S Mawatari M Kawai A

Aims

The risk of postoperative complications after resection of soft-tissue sarcoma in the medial thigh is higher than in other locations. This study investigated whether a vessel sealing system (VSS) could help reduce the risk of postoperative complications after wide resection of soft-tissue sarcoma in the medial thigh.

Methods

Of 285 patients who underwent wide resection for soft-tissue sarcoma between 2014 and 2021 at our institution, 78 patients with tumours in the medial thigh were extracted from our database. Information on clinicopathological characteristics, preoperative treatment, surgical treatment (use of VSS, blood loss volume, operating time), and postoperative course (complications, postoperative haemoglobin changes, total drainage volume, and drainage and hospitalization durations) were obtained from medical records. We statistically compared clinical outcomes between patients whose surgery did or did not use VSS (VSS and non-VSS groups, respectively).


Bone & Joint Research
Vol. 6, Issue 10 | Pages 577 - 583
1 Oct 2017
Sallent A Vicente M Reverté MM Lopez A Rodríguez-Baeza A Pérez-Domínguez M Velez R

Objectives. To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. Methods. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s t-test and Mann–Whitney U test were used. Results. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. Conclusion. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article: A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577–583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 91 - 91
1 Dec 2022
Rizkallah M Aoude A Turcotte R
Full Access

Resection of the proximal femur raises several challenges to the orthopedic oncology surgeon. Among these is the re-establishment of the abductor mechanism that might impacts on hip function. Extent of tumor resection and surgeons’ preferences dictate the reconstruction method of the abductors. While some surgeons advocate the necessity of greater trochanter (GT) preservation whenever possible, others attempt direct soft tissues reattachment to the prosthesis. Sparse data in the literature evaluated the outcomes of greater trochanter fixation to the proximal femur megaprosthesis. This is a retrospective monocentric study. All patients who received a proximal femoral replacement after tumor resection between 2005 and 2021 with a minimum follow-up of three months were included. Patients were divided into two groups: (1) those with preserved GT reattached to the megaprosthesis and (2) those with direct or indirect (tenodesis to fascia lata) abductor muscles reattachment. Both groups were compared for surgical outcomes (dislocation and revision rates) and functional outcomes (Trendelenburg gait, use of walking-assistive device and abductor muscle strength). Additionally patients in group 1 were subdivided into patients who received GT reinsertion using a grip and cables and those who got direct GT reinsertion using suture materials and studied for GT displacement at three, six and 12 months. Time to cable rupture was recorded and analyzed through a survival analysis. Fifty-six patients were included in this study with a mean follow-up of 45 months (3-180). There were 23 patients with reinserted GT (group 1) and 33 patients with soft tissue repair (group 2). Revision rate was comparable between both groups(p=0.23); however, there were more dislocations in group 2 (0/23 vs 6/33; p=0.037). Functional outcomes were comparable, with 78% of patients in group 1 (18/23) and 73% of patients in group 2 (24/33) that displayed a Trendelenburg gait (p=0.76). In group 1, 70% (16/23) used walking aids compared to 79% of group 2 (27/33) (p=0.34). Mean abductor strength reached 2.7 in group 1 compared to 2.3 in group 2 (p=0.06). In group 1, 16 of the 23 patients had GT reinsertion with grip and cables. Median survival of cables for these 16 patients reached 13 months in our series. GT displacement reached a mean of two mm, three mm, and 11 mm respectively at three, six and 12 months of follow-up in patients with grip and cables compared to 12 mm, 24 mm and 26 mm respectively at the same follow-up intervals in patients with GT stand-alone suture reinsertion(p<0.05). Although GT preservation and reinsertion did not improve functional outcomes after proximal femur resection and reconstruction with a megaprosthesis, it was significantly associated with lower dislocation rate despite frequent cable failure and secondary GT migration. No cable or grip revision or removal was recorded. Significantly less displacement was observed in patients for whom GT reattachment used plate and cables rather than sutures only. Therefore we suggest that GT should be preserved and reattached whenever possible and that GT reinsertion benefits from strong materials such as grip and cables


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 37 - 37
1 Nov 2016
Gupta S Kafchinski L Gundle K Saidi K Griffin A Ferguson P Wunder J
Full Access

Biological reconstruction techniques after diaphyseal tumour resection have increased in popularity in recent years. High complication and failure rates have been reported with intercalary allografts, with recent studies questioning their role in limb-salvage surgery. We developed a technique in which large segment allografts are augmented with intramedullary cement and fixed using compression plating. The goal of this study was to evaluate the survivorship, complications and functional outcomes of these intercalary reconstructions. Forty-two patients who had reconstruction with an intercalary allograft following tumour resection between 1989 and 2010 were identified from our prospectively collected database. Allograft survival, local recurrence-free, disease-free and overall survival were assessed using the Kaplan-Meier method. Patient function was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The 23 women and 19 men had a mean age of 33 years (14–77). The most common diagnoses were osteosarcoma (n=16) and chondrosarcoma (n=9). There were 9 humerus, 18 femur and 15 tibia reconstructions. At a mean follow-up of 95 months (5–288), 31 patients were alive without disease, 10 were dead of disease and 1 was deceased of other causes. There were 4 local recurrences and 11 patients developed metastatic disease. 5-year local recurrence free survival was 92%, 5-year disease-free survival was 70% and overall survival was 75%. Fourteen of 42 patients (33%) experienced complications: 5 wound healing complications, 4 infections, 2 non-unions, 2 fractures and 1 nerve palsy. Four allografts (9.5%) were revised for complications and 2 (5%) for local recurrence. Mean allograft survival was 85 months (4–288). Mean time to union was 8.2 (3–36) months for the proximal osteotomy site and 8.1 (3–23) months for the distal osteotomy site. The mean score for MSTS 87 was 29.4 (+/− 4.4), MSTS 93 was 83.7 (+/−14.8) and TESS was 81.6 (+/−16.9). An intercalary allograft augmented with intramedullary cement and compression plate fixation provides a reliable and durable method of reconstruction after tumour resection. Complication rates are comparable to the literature and are associated with high levels of patient function and satisfaction


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 348 - 348
1 Mar 2004
ejovsk ZM Matejovsk Z Knobloch R Kinkor Z i°kovsk‡ K
Full Access

Aims: The purpose of this study is to evaluate the experience of the Prague tumour centre with total hip replacements after tumour resections. Methods: 180 THR were implanted between 1971 and 2001 in the Prague tumour centre after resections of primary and secondary bone tumours. 158 had special long and 22 standard stems. The patients were followed in a minimum one-year interval both clinically and radiologically until their death or for at least þve years. Clinical and radiological data are evaluated. Results: Among the 158 long stem femoral components there were 63 primary bone tumours (10 Ewing sarcoma, 10 myeloma 9 chondrosarcoma, 7 osteosarcoma, 7 malignant þbrous histiocytoma, 4 malignant lymphoma, 4 giant cell tumours and 15 other benign tumours). Most of the 95 metastatic cases originated in the breast, kidney and lungs. The range of motion was surprisingly good when muscles were reattached around the stem. Luxations occurred until the antiluxating cup was developed. Even if these patients showed a higher risk of infection, reoperation was not a severe problem. Conclusions: THR with a long stem is a good salvage method after primary tumour resection around the hip. It is a method of choice in meta-static patients with or without pathologic fractures especially in solitary bone metastasis. Luxation can be a problem when not using an antiluxa-ting cup as well as replacement in children with unþnished skeletal development. Reattachment of the Ç muscle ring È improves the outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 38 - 38
1 Mar 2012
Jaiswal P Aston W Grimer R Abudu A Carter S Blunn G Briggs T Cannon S
Full Access

We performed a retrospective review of 98 patients with malignant tumours of the periacetabular region, treated by resection and endoprosthetic reconstruction between 1971 and 2005 at the Royal National Orthopaedic Hospital, Stanmore and The Royal Orthopaedic Hospital, Birmingham. The mean age of the patients was 43.6 years (10 to 76). 53 patients (54%) were male. The age distribution demonstrated peaks in the 2nd and 6th decades. The mean follow up was 65 months (2 to 405. The overall 10-year survival rate was 56% (determined by the Kaplan-Meier method). 54 patients (58.1%) had one or more complications. Infection was the most common (30%) with the majority occurring in the first 2 years. Dislocation occurred in 19 (20%) of our patients all in the first year following surgery. All were recurrent with a mean of 2.9 (2 to 6) episodes. Operations performed before 1994 were associated with a dislocation rate of 40.5% and after 1996 the rate was only 3.9% (p < 0.001). Function was assessed according the Toronto Extremity Salvage Sore (TESS). The overall TESS was 59.4. In patients that had a major complication the TESS was 37.1 but in the group that did not the TESS was 70.3 (p < 0.001). Men experienced higher rates of death, infection and revision than women (p < 0.05). The local recurrence rate was 31% with high grade tumours associated with higher recurrence rates (p < 0.05). Tumour resection in the ilium is associated with higher rates of infection than tumours located in the periacetabular region alone (p < 0.05). This method of reconstruction is still associated with high complication rates. Function is good if a major complication can be avoided. The lower dislocation rate more recently is probably the result of improved surgical technique and the use of larger femoral heads


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 346 - 346
1 May 2010
Sapkas G Constantinou V Mavrogenis A Papagelopoulos P Papadopoulos E Tzoutzopoulos A Papadakis S Papadakis M
Full Access

Purpose: To present a series of 49 patients which underwent single or two staged complete spondylectomy, vertebral body reconstruction and segmental spinal stabilization due to spinal tumors. Materials and Methods: From 1992 to 2002, 49 patients with primary or metastatic spinal tumors were treated. There were 36 females and 13 males with mean age at operation of 53.5 years (19 – 80). The preoperative classification was Frankel E in 17 cases, B – D in 31 cases and A in one case. Five patients had nerve root dysfunction and one, classified as Frankel E, had sphincter inadequacy. The parts of the spine involved were lower cervical in 7 cases, thoracic in 10, thoracolumbar in 15 and lumbar in 17 cases. The operations were two staged in 36 cases and single staged in 13 cases. In the cervical spine, titanium cylinders filled with methylmethacrylate were used. For the rest of the spine, the most commonly used instruments were the Kaneda device, followed by the Miami–MOSS system. Bone graft was used in five benign tumors. Mean follow – up was 62.3 months. Results: One patient died during the anterior procedure and in another it had to be interrupted, whereupon he died one week later. Two patients died due to their underlying pathology in the 6th post–operative month. Complications included wound healing problems in 9 patients and local recurrence in one patient. There were no neurological deteriorations or instrument failures. The majority of patients experienced improvement in their neurological status, reduction of pain or both. Most patients were functionally improved and spinal alignment was maintained in all. Conclusion: Spinal tumor resection and spinal reconstruction provide stability, early weight bearing, symptom remission and neurological improvement


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 22 - 22
1 Jul 2012
Wafa H Grimer R Carter S Tillman R Abudu A Jeys L
Full Access

Introduction. The aim of this study is to evaluate the functional and oncological outcome of extracorporeally irradiated autografts as a method of pelvic reconstruction after internal hemipelvectomy. Methods. The study included fifteen patients with primary malignant bone tumours of the pelvis. There were 10 males and 5 females with a mean age of 21.5 years (range, 8 to 46 years). Six patients had Ewing's sarcoma, six osteosarcoma, and three chondrosarcoma. Results. At a mean follow-up of 52.3 months (range, 4 to 180 months), five patients were free from disease, nine had died with metastatic disease, while one patient was alive with pulmonary metastasis. Local recurrence occurred in three patients (20%) and all eventually died of disease progression. Two patients developed deep infection which necessitated graft removal. The mean MSTS functional score in those thirteen patients who could be followed up for at least 12 months was 77% (range, 60-87%). According to Mankin's allograft functional grading system, there were five excellent, five good, one fair result and two failures. Discussion. Periacetabular reconstruction after tumour resection is a real challenge to orthopaedic surgeons. There is no ideal method of reconstruction and the decision needs to be individualized. Extracorporeal irradiation and re-implantation of bone is a valid method of reconstruction after pelvic resections with acceptable morbidity rate and functional outcome that compares favourably to other available reconstructive techniques


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 20 - 20
1 Mar 2009
Aponte-Tinao L Farfalli G Politi B Abalo E Ayerza M Muscolo D
Full Access

Introduction: Osteoarticular allograft represents a reliable option for distal femur reconstruction. The purpose of this study was to describe the technical details and results of distal femur tumor resection and reconstruction with an osteoarticular allograft. Material and Methods: One hundred and twenty-two patients who received an osteoarticular allograft after distal femur resection were reviewed, with a mean follow-up of 7 years. Key points for successful fixation are allograft selection, absolute stability and satisfactory soft-tissue reconstruction at the time of surgery that allows aggressive rehabilitation. Survival of the allograft was estimated with the Kaplan-Meier method. Functional and radiographic results were documented according to the Musculoskeletal Tumor Society scoring system at the time of the latest follow-up. Results: Three patients were lost to follow and twenty-three patients died for tumor related reasons without allograft failure. In the remaining 96 allografts, eighteen allografts failed due to 7 infections, 7 local recurrences, 1 massive resorption and 3 fractures. Overall allograft survival was 82% +/− 7.6% (+/− 2 SE) at five and ten years. Those patients who preserved the original allograft had an average functional score of 27 points and a mean radiographic score of 89%, which represents a good and excellent functional and radiographic result. Discussion and conclusion: Osteoarticular allograft is a successful procedure for reconstruction of the distal femur. Adequate preoperative planning, careful surgical technique and aggressive rehabilitation lead to excellent function and low complication rate


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 226 - 226
1 Mar 2003
Demertzis N Mourikis A Kottakis S
Full Access

Our study includes 20 patients with femoral tumors during the years 1997–2002. The primary tumors were 5 sarcomas and 3 myelomas and we had 12 metastatic bone tumors. We used 12 modular prothesis and 8 long stem revision both for primary and for metastatic bone tumors. We applied special surgical techniques for the prevention of hip dislocation, the most common complication of proximal femoral resections. In our study we describe the various surgical techniques used, the modes of application of the endoprothesis and also the techniques of the soft tissue reconstruction, hi 17 cases we used bipolar hemiarthroplasty and in 3 cases, where acetabular metastasis was evident, we used special endoprothesis which allowed us to reconstruct the acetabulum with the use of a special plexus. The most frequently used approach was the anterolateral. In one case we used an anteromedial approach due to the femoral triangle invasion by the tumor. We put special emphasis in the techniques of the soft tissue reconstruction, like capsuloplasty, with the use of a Dacron plexus under a specific modification. This plexus was also used as an extension to cover the muscular defects created due to wide tumor resection. The follow up period ranged from 6 months up to 5 years. Out of the 20 cases we had only one dislocation. The functional results according to the Ennekin scale were: Excellent – Good: 65%, Fair: 30%, Poor: 5%. In conclusion, the new reconstruction techniques and the appropriate application of the modular prothesis that also preserve the femoral length, provide very good joint stability with good functional results


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 65 - 66
1 Jan 2004
Fiorenza F Kulkarni A Grimer R Carter S Tillman R Charissoux J Pynsent P
Full Access

Purpose: Primary bone tumours situated at the distal end of the humerus are exceptional and observed in only 1% of the cases. Reconstruction at this level is often difficult due to the wide bone resection. Choosing a massive prosthesis is an interesting method allowing correct carcinological and functional results. We report a series of ten patients who underwent reconstruction of the lower end of the humerus between 1970 and 2001 with a massive prosthesis after tumour resection. Material and methods: This series included four men and six women, mean age 51 years (15–76). Eight patients had primary bone tumours and two had secondary bone lesions. Mean follow-up was 79 months (9–372). The custom-made constrained hinge prosthesis composed of chromium-cobalt and titanium was cemented. Regular clinical and radiological follow-up data were recorded. The Henneking score and the Toronto Extremity Survival Score (TESS) were used to assess functional outcome. Results: Three patients underwent revision for aseptic loosening of the humeral component at 48, 56 and 366 months with problem of polyethylene insert wear for two of them. There were no infctions or local recurrences and no secondary amputations. The posterior or anterolateral approach was used for humeral resection (mean 153 mm, 63–160 mm). Postoperatively, three patients developed transient palsy (one radial and two ulnar) which regressed. Four patients died from metastasis and had a satsifactory prosthesis result at time of death. The mean TESS was 73% (29–93%) at last follow-up. Discussion: Although this is a small series, the long-term results appear to indicate that reconstruction of the lower extremity of the humerus with a massive prosthesis is a satisfactory option for this rare tumour localisation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 56 - 56
1 Dec 2017
DePaolis N Romagnoli C Romantini M Frisoni T Donati D
Full Access

Reconstruction of pelvic bone defect after resection for bone tumours is a challenging procedure especially when the hip joint is involved due to the anatomy and the complex biomechanical and structural function of the pelvic ring. This surgery is associated to high complication rate. The additive 3D printing technology allows us to produce trabecular titanium custom based implants with an accurate planning of resection using bone cutting jigs. From August 2013 to January 2017, we treated 8 patients for bone pelvic sarcoma with custom-made osteotomy jigs (Nylon) and custom-made trabecular titanium prosthesis produced through rapid prototyping technology based on mirroring of the contralateral hemipelvis. Mean follow up time was 18 months (range 2–30) Wide margins were obtained in all cases, in one a local recurrence developed. Surgical time was 4 hours average (from 180 to 250 mins). No postoperative complications were reported. Rapid prototyping is a promising technique in order to achieve wide surgical margins and restore the anatomy in pelvic bone tumour resection as well as reducing complications


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 93 - 93
1 Mar 2009
Bianchi G Donati D Di Bella C Colangeli M Colangeli S Mercuri M
Full Access

Introduction: The use of allograft prosthetic composite (APC) of the proximal tibia offers advantages over prosthetic replacement or osteoarticular graft with a better functional outcome since the possibility of a careful soft tissue reconstruction;. Materials and Methods: From 1994 to 2002, 62 APC of the proximal tibia were performed in our department after bone tumor resection (56 malignant bone tumors, 4 cases of previously failed knee implant and 2 stage 3 benign tumors). The patients median age was 18 yrs (range: 11–77 yrs) and the mean resected length was 13.2 cm (range: 8.5–28 cm). The median follow up was 59 months (range: 13–137 months). Results: In three patients (4,8%) a recurrence was reported at 22, 33 an 40 months and amputation was performed. Infection was reported in 15 patients (24.2%): 2 early infections (healed with surgical debridment), 1 femoral stem septic loosening (treated with early revision with cemented stem); in 8 cases removal of the infected APC was required followed by implant of a new prosthetic device after cement spacer; two infections did not healed and patient underwent amputation; in two cases a good functional result was achieved removing the infected graft and covering the proximal tibia with cement and no other surgery was required. Non union of the graft was observed in 8 patients (12.9%): in 4 patients autologous bone grafting was necessary to heal the osteotomy line. In other 3 cases non union was associated with graft fracture. In one case non union was associated with tibial stem loosening and revision of the whole implant was done. Polyethylene wear was assessed in 5 patients (8%) and revision of the polyethylene components was always required. Nine patellar tendon rupture (14.5%) were assessed and repaired was performed in seven cases. The functional outcome of 42 patients with more than two years of follow up was excellent in 25 cases, good in 13, fair in 2 and poor in 2. Discussion: APC of the proximal tibia is an effective alternative to osteoarticular graft and modular prosthesis because it allows good to excellent results in most of the patients (90.4%). The major concern is infection rate (24.2%) that usually lead to amputation (80%). Non union does not usually represent a problem because it’s tendency to spontaneous or bone grafting induced healing. Aseptic loosening of the tibial or femoral stem is rare. Patellar tendon rupture rate (14.5%) is similar to modular prosthetis rate and can be lowered using a femoral component with patellar groove


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 36 - 36
1 Oct 2014
Ritacco L Milano F Farfalli GL Aponte-Tinao LA
Full Access

Introduction. Three-dimensional preoperative planning and bone tumour resection by navigation have been used in the past ten years. According to literature this workflow increases the surgical “accuracy”. However, there are a few and not completely clear reports describing accuracy in preoperative planning and navigation. The objective of this preliminary study was to determine the accuracy of osteotomies planned and guided by navigation in pelvis tumour resection. We assume that the surgical specimen scanned and 3D reconstructed is an acceptable method to determine the accuracy qualitatively and quantitatively of a virtual planning and navigation surgical workflow. Materials and Methods. A total of four patients were evaluated between May 2010 and February 2011, age range: 6–38, 17.4 mean; 2 males and 2 females. There were 4 malignant tumours: Malignant Schwannoma (1), Ewing's tumor (1) and Chondrosarcoma (2). All anatomic regions compromised by the tumour were preoperatively CT scanned (Mutislice 64, Aquilion, Toshiba Medical Systems, Otawara, Japan). Magnetic resonance images (MRI) of the corresponding region were acquired using a 1.5-T unit (Magnetom Avanto, Siemens Medical Solutions, Erlangen, Germany). Image fusion was applied to CT and MRI studies in order to determine the bone cortex and the intra-extraosseous soft tissues tumour extension. Once the fusion was obtained osteotomies were planned, taking into account the tumour extension in a three-dimensional virtual scenario. All patients were planned for two uniplanar osteotomies (intercalary resection). The minimal margin was determined in each plane by measuring the closest distance between malignant tumour and osteotomy plane. These studies allowed the visualisation of the tumour and the application of a virtual osteotomy. The simulation was carried out by using a computer-aided design (CAD) software, Mimics (Materialise, Leuven, Belgium). Three-dimensional preoperative planning was obtained in CAD format. Next, 3D models were exported to CT data sets in Digital Imaging and Communications in Medicine (DICOM) format and uploaded to the navigation system (3D OrthoMap navigation software v1.0, Stryker Navigator, Freiburg, Germany). Using the standard navigation tools (navigated pointer, camera and infrared tracker devices applied to the patient) the surgeon was able to establish a correspondence in a computer monitor between 3D images and real bone. Once osteotomies were performed, the tumour surgical specimen obtained was CT scanned and 3D reconstructed similarly to what was done previously to surgery to CT images acquired with the preoperative protocol in patients. Results. The correlation between the osteotomies preoperatively planned and the osteotomies achieved by navigation was in a global mean of 0.73 millimeters (SD: 3.14) in a total of 6 planes evaluated. Conclusion. According to clinical relevance, this work shows an acceptable accuracy in preoperative planning and navigation. Furthermore, we demonstrate the usefulness of three-dimensional models of surgical specimens when surgeons need to determine quantitative and qualitative accuracy of 3D planning and navigation procedures


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 281 - 281
1 May 2010
Funovics P Dominkus M Abdolvahab F Kotz R
Full Access

Fibula autograft reconstruction, both vascularised (v) and non-vascularised (nv), has been established as a standard method in limb salvage surgery of bone and soft tissue tumours of the extremities. This study retrospectively analyses the results of fibula autograft procedures in general and in relation to vascular reconstruction or simple bone grafting. Since the implementation of the Vienna Tumour Registry in 1969, 26 vascularised and 27 non-vascularised fibula transfers have been performed at our institution in 53 patients, 26 males and 27 females with an average age of 21 years (range 4 to 62 years). Indications included osteosarcoma in 18, Ewing’s Sarcoma in 15, adamantinoma in 5, leiomyosarcoma in 3 and others in 12. Thirty patients were operated for reconstruction of the tibia (8v/22 nv), 7 for the femur (6v/1nv), 7 for defects of the forearm (4v/3nv), 5 for metarsal defects (all v), 3 for the humerus (1v/2nv) and one patient was treated for a pelvic defect (nv). Average follow-up was 63 months (range 2 to 259 months). 43 patients showed successful primary bony union of the autograft. In 12 cases pseudarthrosis indicated further surgical revision, 9 of these patients were primarily reconstructed by use of a nv autograft. 4 patients, 2 with v and 2 with nv reconstruction, suffered a fracture of the transplant and were operated for secondary osteosynthesis. 10 patients with v bone graft developed wound healing disturbances which led to surgery, 2 patients with nv grafts suffered such complications. In 2 patients recurrent infection of a nv and a v fibula transfer led to the implantation of a modular tumour prostheses or amputation, retrospectively. Function of all patients with primary bone healing was rated satisfactory. The use of fibula autograft in limb-salvage surgery under oncological conditions allows biological reconstruction with good functional outcome, especially when primary bone healing is achieved. Vascularised bone grafting seems to have a better outcome in terms of primary bone healing than simple fibula bone grafting, and thus represents a feasible choice in the reconstruction of bone defects from tumour resection


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 32 - 32
1 Apr 2012
van de Sande M Dijkstra PS Taminiau A
Full Access

The purpose of this study was to compare the outcome, complications and survival of the three most commonly used surgical reconstructions of the proximal humerus in adult patients after trans-articular tumour resection. Method. Between1985 and 2005 thirty-eight consecutive proximal humeral reconstructions using either, allograft-prosthesis composite (n=10), osteoarticular allograft (n=13) or a modular tumour prosthesis (n=14), were performed in our clinic. Their mean follow-up was ten years (nine months to 25 years). Of these, twenty-seven were disease free at latest follow-up (Mean follow-up 16.8 years) and ten had died of disease (4.2 years). Complications and implant survival with revision surgery as end-point are presented for the total group of patients, functional scores for surviving patients only. Results. The endoprosthetic group presented the smallest complication rate of 21%, compared to 40% in the allograftprosthesis- composite and 62% in the osteoarticular allograft group. Only one revision was performed in the endoprosthetic group, in a case of shoulder instability. Infection after revision (n=3), pseudoarthrosis (n=2), fracture of the allograft (n=3), and shoulder instability (n=4) were major complications of allograft use in general. Kaplan-Meier-analysis showed a significantly better implant survival for the endoprosthetic group (log-rank p=0.002). At final follow-up the MusculoSkeletal Tumour Society scores averaged at; 72% for the allograft-prosthetic-composite (n=7, mean follow-up 19 years), 76% for the osteoarticular allograft (n=3, 16 years), and 77% for the endoprosthetic reconstruction (n=10, 6 years) groups. Conclusion. An endoprosthetic reconstruction after trans-articular proximal humeral resection resulted in the lowest complication rate, highest implant survival and comparable functional results when compared to allograft-prosthesiscomposite and osteoarticular-allograft use. For all types of reconstruction, gleno-humeral instability remains a major cause of dysfunction at long-term FU. We believe that the additional use of a knitted tube surrounding the humeral prosthesis may have decreased the high incidence of this complication reported in recent literature


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 33 - 33
1 Apr 2012
Ebeid W Ghoneimy A Amin S
Full Access

Several methods have been used for proximal humeral reconstruction following tumour resection. None of these modalities allow the patient to regain his normal shoulder range of motion. Moreover, every modality has its advantages and disadvantages. The aim of this study was to compare the functional outcome of 2 reconstructive modalities that we are using in our institution for proximal humeral reconstruction; endoprosthesis and shoulder arthrodesis using a vascularised autograft This study included 48 patients diagnosed with malignant or benign aggressive tumours that required resection of their proximal humerus. They were divided into 2 groups according to the method of reconstruction. Group 1 included 22 patients with an average age of 20 years were reconstructed by shoulder arthrodesis using a free vascularised fibular graft (6) or a pedicled scapular crest graft (16). Group 2 included 26 patients with an average age of 26 years were reconstructed with an endoprosthesis. In group 1 the average follow up period was 88 months (range 12 to 184 months). The average functional outcome (according to the MSTS scoring system) was 25 points (range 19 – 28). The average abduction and forward flexion range of motion (scapulothoracic) was 40 degrees (range 20 -60). Complications included failed fixation (2), non union (1), infection (1) and temporary radial nerve palsy (2). In group 2 the average follow up period was 36 months (range 12 – 110). The average functional outcome was 24 points (range 20 – 27). The average abduction and forward flexion range of motion was 40 (range 30 –70). Complications included sublaxation (2), loosening (1) and infection (1). Reconstruction of the proximal humerus by arthrodesis or endoprosthesis yield similar functional outcome. Although endoprosthesis is a much more expensive modality, it does not provide any superior functional outcome over shoulder arthrodesis