header advert
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 6 - 6
13 Mar 2023
Pawloy K Sargeant H Smith K Rankin I Talukdar P Hancock S Munro C
Full Access

Our unit historically performed total hip replacement (THR) through either posterior or anterolateral approaches. In November 2020 a group of 5 consultants transitioned to utilising the Direct Anterior Approach (DAA). Appropriate training was undertaken and cases were performed as dual consultant procedures with intraoperative radiography or robotic assistance. Outcomes were collated prospectively. These included basic demographics, intraoperative details, complication rates and Oxford Hip Scores. A total of 48 patients underwent DAA THR over 1 year. Mean age was 67 and ASA 2. Over this time period 140 posterior approach and 137 anterolateral approach THR's were performed with available data. Propensity score matching was performed on a 1:1 basis using BMI, Age, Sex and ASA as covariates to generate a matched cohort group of conventional approach THR (n=37). Length of stay was significantly reduced at 1.95 days (p<0.001) with DAA compared to Anterolateral and Posterior approach. There was no significant difference with length of surgery, blood loss, Infection, dislocation and periprosthetic fracture rate. There was no significant difference in Oxford Hip Score between any approach at 3 months or 1 year. The transition to this approach has not made a negative impact despite its associated steep learning curve, and has improved efficiency in elective surgery. From our experience we would suggest those changing to this approach receive appropriate training in a high-volume centre, and perform cases as dual consultant procedures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 235 - 235
1 Sep 2012
Lipperts M Senden R Van Asten W Heyligers I Grimm B
Full Access

Introduction. In orthopaedics, clinical outcome assessment (COA) is mostly performed by questionnaires which suffer from subjectivity, a ceiling effect and pain dominance. Real life activity monitoring (AM) can objectively assess function and becomes now feasible as technology has become smaller, lighter, cheaper and easier to use. In this study we validated a custom made algorithm based on accelerometry using different orthopaedic patients with the aim to use AM in orthopaedic COA. Methods. A small, lightweight 3D-accelerometer taped to the lateral side of the affected upper leg served as the activity monitor. AM algorithms were programmed in Matlab to classify standing, sitting, and walking. For validation a common protocol was used; subjects were asked to perform several tasks for 5 or 10 seconds in a fixed order. An observer noted the starting time of each task using a stopwatch. Accuracy was calculated for the number of bouts per activity as well as total time per activity. 10 Subjects were chosen with different pathologies (e.g. post total knee/hip arthroplasty, osteoarthritis) since the difference in movement dynamics in each pathology poses a challenge to the algorithm. Results. In total the subjects performed 267 activities (99 standing, 80 sitting, 88 walking), 258 of which (99, 73, 87 resp.) were classified correctly by the algorithm, corresponding to a sensitivity of 97%. Sensor misplacement in 1 subject caused all missed instances in sitting, and exclusion of this subject increased sensitivity to 99.9%. 5 Instances of standing were incorrectly added by the algorithm, giving a specificity of 95% for standing. In total 80 sit-stand, and 78 stand-sit transitions were performed. Subjects were standing for 792 seconds, sitting for 764 s, and walking for 905 s. The algorithm found a total duration of 739, 583 and 1056 seconds for those activities respectively, and 83 seconds of lying (misclassification of sitting). Discussion. Sensor placement is an important factor to obtain reliable results. Even so sensitivity and specificity are comparable to values found in literature [85–99%]. The added instances of standing occurred when a subject did not immediately sit after a period of walking. It is doubtful if these instances should be considered false positives. The main difference in duration is also found in sitting, which is caused by the missed instances previously described, in combination with the fact that the duration of transitions are added to the walking period in the algorithm, whereas it is divided over sitting and walking by the observer. This corresponds to a difference of less than one second per transition. The algorithm produces reliable results when challenged with different movement patterns common with orthpaedic pathologies. The device may be used as as AM in objective assessment of clinical outcome after orthopaedic procedures


Bone & Joint Open
Vol. 5, Issue 3 | Pages 218 - 226
15 Mar 2024
Voigt JD Potter BK Souza J Forsberg J Melton D Hsu JR Wilke B

Aims

Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients.

Methods

Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1362 - 1368
1 Dec 2022
Rashid F Mahmood A Hawkes DH Harrison WJ

Aims

Prior to the availability of vaccines, mortality for hip fracture patients with concomitant COVID-19 infection was three times higher than pre-pandemic rates. The primary aim of this study was to determine the 30-day mortality rate of hip fracture patients in the post-vaccine era.

Methods

A multicentre observational study was carried out at 19 NHS Trusts in England. The study period for the data collection was 1 February 2021 until 28 February 2022, with mortality tracing until 28 March 2022. Data collection included demographic details, data points to calculate the Nottingham Hip Fracture Score, COVID-19 status, 30-day mortality, and vaccination status.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 980 - 986
1 Aug 2022
Ikram A Norrish AR Marson BA Craxford S Gladman JRF Ollivere BJ

Aims

We assessed the value of the Clinical Frailty Scale (CFS) in the prediction of adverse outcome after hip fracture.

Methods

Of 1,577 consecutive patients aged > 65 years with a fragility hip fracture admitted to one institution, for whom there were complete data, 1,255 (72%) were studied. Clinicians assigned CFS scores on admission. Audit personnel routinely prospectively completed the Standardised Audit of Hip Fracture in Europe form, including the following outcomes: 30-day survival; in-hospital complications; length of acute hospital stay; and new institutionalization. The relationship between the CFS scores and outcomes was examined graphically and the visual interpretations were tested statistically. The predictive values of the CFS and Nottingham Hip Fracture Score (NHFS) to predict 30-day mortality were compared using receiver operating characteristic area under the curve (AUC) analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 1 - 1
1 Sep 2013
Wallace DT Mahendra A Findlay H Jane MJ
Full Access

Bone and soft tissue sarcoma is an uncommon. Benign swellings are, however, common. An approach to tertiary referral is required to accommodate the need for specialist interpretation of all concerning referrals, while maintaining an acceptable time to diagnosis and management. We aim to describe a new tertiary sarcoma service, utilising modern communication technology and the “virtual clinic” model through a multidisciplinary approach. All suspected musculoskeletal sarcoma cases are discussed, with available history and imaging, in a virtual clinic by a multidisciplinary team within a week of referral. Clinic decisions allow either immediate discharge, progress to further investigation, or clinic appointment. Data from the first thousand patients was prospectively collected for initial management decision, and final intervention, and in 625 for waiting time. Almost one third of patients were discharged from the virtual clinic without physical appointment. 45% were sent for further investigation prior to first clinic appointment. Of 625 patients with referral data, mean waiting time was 5.1 days to virtual clinic. For malignant bone and soft tissue tumours, not requiring neoadjuvant treatment, median time to surgery from virtual clinic review was 37 and 47 days respectively. Through a virtual clinic approach to tertiary sarcoma care, almost a third of referrals have been managed quickly without need for an unnecessary appointment. For 45% of patients the first appointment will be after all necessary investigations have been performed to facilitate rapid decision making. This enables shorter clinic waiting times and rapid transition from first referral to definitive management


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 54 - 54
1 Apr 2013
Cheng TL Valchev P Dehghani F Little DG Schindeler A
Full Access

Introduction. Bone tissue engineering approaches are an emerging strategy to treat bone defects, and commonly involve the delivery of osteogenic cells and/or drugs via a porous scaffold. We have been exploring an alternative injectable approach for drug delivery that would obviate the need for invasive surgery. Hypothesis. Sucrose Acetate Isobutyrate (SAIB) is a sucrose-based ester that is a highly viscous semi-solid. Diluting SAIB with 10–20% ethanol markedly reduces its viscosity, with ethanol diffusing rapidly after in vivo injection. This phase transitioning property makes SAIB an ideal candidate for bone tissue engineering. Materials and methods. The capacity of SAIB to act as a delivery system for recombinant human BMP-2 (rhBMP-2) was tested in a mouse ectopic bone formation model. In this model SAIB was used to deliver 0 to 10μg rhBMP-2. Next, SAIB was compared with porous collagen scaffold used clinically to delivery rhBMP-2 in a head-to-head trial. Commercial SAIB and SAIB produced in-house were also compared. Bone volumes were quantified by μCT. Discussion. Bone was found to form with as little as 2μg rhBMP-2 when delivered with SAIB. Injected SAIB also showed minimal inflammatory response and rapid breakdown, with bone formation occurring between one and two weeks. Conclusion. SAIB was found to be an effective delivery system for rhBMP-2 with translational utility. Future work will be required to examine the upscaling of this delivery system


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 462 - 468
1 Mar 2021
Mendel T Schenk P Ullrich BW Hofmann GO Goehre F Schwan S Klauke F

Aims

Minimally invasive fixation of pelvic fragility fractures is recommended to reduce pain and allow early mobilization. The purpose of this study was to evaluate the outcome of two different stabilization techniques in bilateral fragility fractures of the sacrum (BFFS).

Methods

A non-randomized, prospective study was carried out in a level 1 trauma centre. BFFS in 61 patients (mean age 80 years (SD 10); four male, 57 female) were treated surgically with bisegmental transsacral stablization (BTS; n = 41) versus spinopelvic fixation (SP; n = 20). Postoperative full weightbearing was allowed. The outcome was evaluated at two timepoints: discharge from inpatient treatment (TP1; Fitbit tracking, Zebris stance analysis), and ≥ six months (TP2; Fitbit tracking, Zebris analysis, based on modified Oswestry Disability Index (ODI), Majeed Score (MS), and the 12-Item Short Form Survey 12 (SF-12). Fracture healing was assessed by CT. The primary outcome parameter of functional recovery was the per-day step count; the secondary parameter was the subjective outcome assessed by questionnaires.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 17 - 25
1 Jan 2020
Trickett RW Mudge E Price P Pallister I

Aims

The aim of this study was to develop a psychometrically sound measure of recovery for use in patients who have suffered an open tibial fracture.

Methods

An initial pool of 109 items was generated from previous qualitative data relating to recovery following an open tibial fracture. These items were field tested in a cohort of patients recovering from an open tibial fracture. They were asked to comment on the content of the items and structure of the scale. Reduction in the number of items led to a refined scale tested in a larger cohort of patients. Principal components analysis permitted further reduction and the development of a definitive scale. Internal consistency, test-retest reliability, and responsiveness were assessed for the retained items.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 527 - 534
1 Apr 2018
Hansson E Hagberg K Cawson M Brodtkorb TH

Aims

The aim of this study was to compare the cost-effectiveness of treatment with an osseointegrated percutaneous (OI-) prosthesis and a socket-suspended (S-) prosthesis for patients with a transfemoral amputation.

Patients and Methods

A Markov model was developed to estimate the medical costs and changes in quality-adjusted life-years (QALYs) attributable to treatment of unilateral transfemoral amputation over a projected period of 20 years from a healthcare perspective. Data were collected alongside a prospective clinical study of 51 patients followed for two years.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1118 - 1125
1 Aug 2015
Kwasnicki RM Hettiaratchy S Okogbaa J Lo B Yang G Darzi A

In this study we quantified and characterised the return of functional mobility following open tibial fracture using the Hamlyn Mobility Score. A total of 20 patients who had undergone reconstruction following this fracture were reviewed at three-month intervals for one year. An ear-worn movement sensor was used to assess their mobility and gait. The Hamlyn Mobility Score and its constituent kinematic features were calculated longitudinally, allowing analysis of mobility during recovery and between patients with varying grades of fracture. The mean score improved throughout the study period. Patients with more severe fractures recovered at a slower rate; those with a grade I Gustilo-Anderson fracture completing most of their recovery within three months, those with a grade II fracture within six months and those with a grade III fracture within nine months.

Analysis of gait showed that the quality of walking continued to improve up to 12 months post-operatively, whereas the capacity to walk, as measured by the six-minute walking test, plateaued after six months.

Late complications occurred in two patients, in whom the trajectory of recovery deviated by > 0.5 standard deviations below that of the remaining patients. This is the first objective, longitudinal assessment of functional recovery in patients with an open tibial fracture, providing some clarification of the differences in prognosis and recovery associated with different grades of fracture.

Cite this article: Bone Joint J 2015; 97-B:1118–25.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1535 - 1539
1 Nov 2014
Tonne BM Kempton LB Lack WD Karunakar MA

The purpose of this study was to describe the radiological characteristics of a previously unreported finding: posterior iliac offset at the sacroiliac joint and to assess its association with pelvic instability as measured by initial displacement and early implant loosening or failure. Radiographs from 42 consecutive patients with a mean age of 42 years (18 to 77; 38 men, four women) and mean follow-up of 38 months (3 to 96) with Anteroposterior Compression II injuries, were retrospectively reviewed. Standardised measurements were recorded for the extent of any diastasis of the pubic symphysis, widening of the sacroiliac joint, static vertical ramus offset and a novel measurement (posterior offset of the ilium at the sacroiliac joint identified on axial CT scan). Pelvic fractures with posterior iliac offset exhibited greater levels of initial displacement of the anterior pelvis (anterior sacroiliac widening, pubic symphysis diastasis and static vertical ramus offset, p < 0.001,0.034 and 0.028, respectively). Pelvic fractures with posterior ilium offset also demonstrated higher rates of implant loosening regardless of fixation method (p = 0.05). Posterior offset of the ilium was found to be a reliable and reproducible measurement with substantial inter-observer agreement (kappa = 0.70). Posterior offset of the ilium on axial CT scan is associated with greater levels of initial pelvic displacement and early implant loosening.

Cite this article: Bone Joint J 2014;96-B:1535–9.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 414 - 419
1 Mar 2016
Metcalfe D Gabbe BJ Perry DC Harris MB Ekegren CL Zogg CK Salim A Costa ML

Aims

In this study, we aimed to determine whether designation as a major trauma centre (MTC) affects the quality of care for patients with a fracture of the hip.

Patients and Methods

All patients in the United Kingdom National Hip Fracture Database, between April 2010 and December 2013, were included. The indicators of quality that were recorded included the time to arrival on an orthopaedic ward, to review by a geriatrician, and to operation. The clinical outcomes were the development of a pressure sore, discharge home, length of stay, in-hospital mortality, and re-operation within 30 days.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 249 - 253
1 Feb 2014
Euler SA Hengg C Kolp D Wambacher M Kralinger F

Antegrade nailing of proximal humeral fractures using a straight nail can damage the bony insertion of the supraspinatus tendon and may lead to varus failure of the construct. In order to establish the ideal anatomical landmarks for insertion of the nail and their clinical relevance we analysed CT scans of bilateral proximal humeri in 200 patients (mean age 45.1 years (sd 19.6; 18 to 97) without humeral fractures. The entry point of the nail was defined by the point of intersection of the anteroposterior and lateral vertical axes with the cortex of the humeral head. The critical point was defined as the intersection of the sagittal axis with the medial limit of the insertion of the supraspinatus tendon on the greater tuberosity. The region of interest, i.e. the biggest entry hole that would not encroach on the insertion of the supraspinatus tendon, was calculated setting a 3 mm minimal distance from the critical point. This identified that 38.5% of the humeral heads were categorised as ‘critical types’, due to morphology in which the predicted offset of the entry point would encroach on the insertion of the supraspinatus tendon that may damage the tendon and reduce the stability of fixation.

We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk.

Cite this article: Bone Joint J 2014;96-B:249–53.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 658 - 664
1 May 2014
Teo BJX Koh JSB Goh SK Png MA Chua DTC Howe TS

Management of bisphosphonate-associated subtrochanteric fractures remains opinion- or consensus-based. There are limited data regarding the outcomes of this fracture.

We retrospectively reviewed 33 consecutive female patients with a mean age of 67.5 years (47 to 91) who were treated surgically between May 2004 and October 2009. The mean follow-up was 21.7 months (0 to 53). Medical records and radiographs were reviewed to determine the post-operative ambulatory status, time to clinical and radiological union and post-fixation complications such as implant failure and need for second surgery.

The predominant fixation method was with an extramedullary device in 23 patients. 25 (75%) patients were placed on wheelchair mobilisation or no weight-bearing initially. The mean time to full weight-bearing was 7.1 months (2.2 to 29.7). The mean time for fracture site pain to cease was 6.2 months (1.2 to 17.1). The mean time to radiological union was 10.0 months (2.2 to 27.5). Implant failure was seen in seven patients (23%, 95 confidence interval (CI) 11.8 to 40.9). Revision surgery was required in ten patients (33%, 95 CI 19.2 to 51.2).

A large proportion of the patients required revision surgery and suffered implant failure. This fracture is associated with slow healing and prolonged post-operative immobility.

Cite this article: Bone Joint J 2014;96-B:658–64.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 72 - 76
1 Jan 2007
Patel V Day A Dinah F Kelly M Bircher M

Specific radiological features identified by Brandser and Marsh were selected for the analysis of acetabular fractures according to the classification of Letournel and Judet. The method employs a binary approach that requires the observer to allocate each radiological feature to one of two groups. The inter- and intra-observer variances were assessed. The presence of articular displacement, marginal impaction, incongruity, intra-articular fragments and osteochondral injuries to the femoral head were analysed by a similar method. These factors were termed ‘modifiers’ and are generally considered when planning operative intervention and, critically, they may influence prognosis.

Six observers independently assessed 30 sets of plain radiographs and CT scans on two separate occasions, 12 weeks apart. They were asked to determine the presence or absence of specific radiological features. This simple binary approach to classification yields an inter- and intra-observer agreement which ranges from moderate to near-perfect (κ = 0.49 to 0.88 and κ = 0.57 to 0.88, respectively). A similar approach to the modifiers yields only slight to fair inter-observer agreement (κ = 0.20 to 0.34) and slight to moderate intra-observer agreement (κ = 0 to 0.55).