Advertisement for orthosearch.org.uk
Results 1 - 20 of 417
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 174 - 181
1 Feb 2024
Mandalia KP Brodeur PG Li LT Ives K Cruz Jr. AI Shah SS

Aims. The aim of this study was to characterize the influence of social deprivation on the rate of complications, readmissions, and revisions following primary total shoulder arthroplasty (TSA), using the Social Deprivation Index (SDI). The SDI is a composite measurement, in percentages, of seven demographic characteristics: living in poverty, with < 12 years of education, single-parent households, living in rented or overcrowded housing, households without a car, and unemployed adults aged < 65 years. Methods. Patients aged ≥ 40 years, who underwent primary TSA between 2011 and 2017, were identified using International Classification of Diseases (ICD)-9 Clinical Modification and ICD-10 procedure codes for TSA in the New York Statewide Planning and Research Cooperative System database. Readmission, reoperation, and other complications were analyzed using multivariable Cox proportional hazards regression controlling for SDI, age, ethnicity, insurance status, and Charlson Comorbidity Index. Results. A total of 17,698 patients with a mean age of 69 years (SD 9.6), of whom 57.7% were female, underwent TSA during this time and 4,020 (22.7%) had at least one complication. A total of 8,113 patients (45.8%) had at least one comorbidity, and the median SDI in those who developed complications 12 months postoperatively was significantly greater than in those without a complication (33 vs 38; p < 0.001). Patients from areas with higher deprivation had increased one-, three-, and 12-month rates of readmission, dislocation, humeral fracture, urinary tract infection, deep vein thrombosis, and wound complications, as well as a higher three-month rate of pulmonary embolism (all p < 0.05). Conclusion. Beyond medical complications, we found that patients with increased social deprivation had higher rates of humeral fracture and dislocation following primary TSA. The large sample size of this study, and the outcomes that were measured, add to the literature greatly in comparison with other large database studies involving TSA. These findings allow orthopaedic surgeons practising in under-served or low-volume areas to identify patients who may be at greater risk of developing complications. Cite this article: Bone Joint J 2024;106-B(2):174–181


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 77 - 77
1 Dec 2022
Spangenberg G Langohr GD Faber KJ Reeves J
Full Access

Total shoulder arthroplasty implants have evolved to include more anatomically shaped components that replicate the native state. The geometry of the humeral head is non-spherical, with the sagittal diameter of the base of the head being up to 6% (or 2.1-3.9 mm) larger than the frontal diameter. Despite this, many TSA humeral head implants are spherical, meaning that the diameter must be oversized to achieve complete coverage, resulting in articular overhang, or portions of the resection plane will remain uncovered. It is suspected that implant-bone load transfer between the backside of the humeral head and the cortex on the resection plane may yield better load-transfer characteristics if resection coverage was properly matched without overhang, thereby mitigating proximal stress shielding. Eight paired cadaveric humeri were prepared for reconstruction with a short stem total shoulder arthroplasty by an orthopaedic surgeon who selected and prepared the anatomic humeral resection plane using a cutting guide and a reciprocating sagittal saw. The humeral head was resected, and the resulting cortical boundary of the resection plane was digitized using a stylus and an optical tracking system with a submillimeter accuracy (Optotrak,NDI,Waterloo,ON). A plane was fit to the trace and the viewpoint was transformed to be perpendicular to the plane. To simulate optimal sizing of both circular and elliptical humeral heads, both circles and ellipses were fit to the filtered traces using the sum of least squares error method. Two extreme scenarios were also investigated: upsizing until 100% total coverage and downsizing until 0% overhang. Total resection plane coverage for the fitted ellipses was found to be 98.2±0.6% and fitted circles was 95.9±0.9%Cortical coverage was found to be 79.8 ±8.2% and 60.4±6.9% for ellipses and circles respectively. By switching to an ellipsoid humeral head, a small 2.3±0.3% (P < 0.001) increase in total coverage led to a 19.5±1.3%(P < 0.001) increase in cortical coverage. The overhang for fitted ellipses and circles was 1.7 ±0.7% and 3.8 ±0.8% respectively, defined as a percentage of the total enclosed area that exceeded the bounds of the humerus resections. Using circular heads results in 2.0 ±0.1% (P < 0.001) greater overhang. Upsizing until 100% resection coverage, the ellipse produced 5.4 ±3.5% (P < 0.001) less overhang than the circle. When upsizing the overhang increases less rapidly for the ellipsoid humeral head that the circular one (Figure 1). Full coverage for the head is achieved more rapidly when up-sizing with an ellipsoid head as well. Downsizing until 0% overhang, total coverage and cortical coverage were 7.5 ±2.8% (P < 0.001) and 7.9 ±8.2% (P = 0.01) greater for the ellipse, respectively. Cortical coverage exhibits a crossover point at −2.25% downsizing, where further downsizing led to the circular head providing more cortical coverage. Reconstruction with ellipsoids can provide greater total resection and cortical coverage than circular humeral heads while avoiding excessive overhang. Elliptical head cortical coverage can be inferior when undersized. These initial findings suggest resection-matched humeral heads may yield benefits worth pursuing in the next generation of TSA implant design. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results. A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion. The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface. Cite this article: Bone Joint J 2024;106-B(5):482–491


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 21 - 21
23 Feb 2023
Sandow M Page R Hatton A Peng Y
Full Access

The 2021 Australian Orthopaedic Association National Joint Replacement Registry report indicated that total shoulder replacement using both mid head (TMH) length humeral components and reverse arthroplasty (RTSA) had a lower revision rate than stemmed humeral components in anatomical total shoulder arthroplasty (aTSA) - for all prosthesis types and diagnoses. The aim of this study was to assess the impact of component variables in the various primary total arthroplasty alternatives for osteoarthritis in the shoulder. Data from a large national arthroplasty registry were analysed for the period April 2004 to December 2020. The study population included all primary aTSA, RTSA, and TMH shoulder arthroplasty procedures undertaken for osteoarthritis (OA) using either cross-linked polyethylene (XLPE) or non-cross-linked polyethylene (non XLPE). Due to the previously documented and reported higher revision rate compared to other anatomical total shoulder replacement options, those using a cementless metal backed glenoid components were excluded. The rate of revision was determined by Kaplan-Meir estimates, with comparisons by Cox proportional hazard models. Reasons for revision were also assessed. For a primary diagnosis of OA, aTSA with a cemented XLPE glenoid component had the lowest revision rate with a 12-year cumulative revision rate of 4.7%, compared to aTSA with cemented non-XLPE glenoid component of 8.7%, and RTSA of 6.8%. The revision rate for TMH was lower than aTSA with cemented non-XLPE, but was similar to the other implants at the same length of follow-up. The reason for revision for cemented aTSR was most commonly component loosening, not rotator cuff deficiency. Long stem humeral components matched with XLPE in aTSA achieve a lower revision rate compared to shorter stems, long stems with conventional polyethylene, and RTSA when used to treat shoulder OA. In all these cohorts, loosening, not rotator cuff failure was the most common diagnosis for revision


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 76 - 82
1 Jan 2022
ten Brinke B Hesseling B Eygendaal D Hoelen MA Mathijssen NMC

Aims. Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. Methods. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Results. At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. Conclusion. In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the predictive value of early migration for future loosening in TSA is required. Clinical results revealed a clinically relevant improvement. Cite this article: Bone Joint J 2022;104-B(1):76–82


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 21 - 21
1 Jul 2020
Hartwell M Nelson P Johnson D Nicolay R Christian R Selley R Tjong V Terry M
Full Access

Recent studies have described safe outcomes for short-stays in the hospital after total shoulder arthroplasty. The purpose of this study is to identify pre-operative and operative risk factors for hospital admissions exceeding 24 hours. The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database was queried from 2006 to 2016 for the current procedural terminology (CPT) billing code related to total shoulder arthroplasty. Patients were then grouped as either having a length of stay (LOS) equal to or less than 24 hours or greater than 24 hours. Patients admitted to the hospital prior to the day of surgery were excluded. Patient demographics, co-morbidities, and operative time were then analyzed as risk factors for a hospital stay exceeding 24 hours. Pre-operative co-morbidities included body mass index (BMI), diabetes, smoking, chronic obstructive pulmonary disease (COPD), congestive heart failure (CHF), hypertension, dialysis, chronic steroid or immunosuppressant use, bleeding disorders, and American Society of Anesthesiologists (ASA) Classification. Univariate and multivariate analyses were then performed to identify risk factors associated with 30-day readmission. 14,339 patients met inclusion criteria and 6,507 (45.3%) had a hospital LOS less than or equal to 24 hours. The mean length of hospitalization was 1.95 ± 1.88 days, the average age was 69 ± 9.7 years old, and 56.9% of the patients were female. Following a risk adjusted multivariate analysis, increasing age (odds ratio [OR], 1.03, 95% confidence interval [CI], 1.02–1.03), ASA classification (OR, 1.50, 95% CI, 1.41–1.60), diabetes (OR, 1.69, 95% CI, 1.43–1.99), COPD (OR, 1.35, 95% CI, 1.16–1.57), CHF (OR, 2.67, 95% CI, 1.34–5.33), dialysis (OR, 2.47, 95% CI, 1.28, 4.77), history of a bleeding disorder (OR, 1.50, 95% CI, 1.20–1.88), or increasing operative time (OR, 1.01, 95% CI, 1.01–1.01) were identified as independent risk factors for hospital lengths of stay exceeding 24 hours. Male gender was identified as a protective factor for prolonged hospitalization (OR, 0.50, 95% CI, 0.46–0.53). This study identifies patient demographics, co-morbidities, and operative-relative risk factors that are associated with increased risk for a prolonged hospitalization following total shoulder arthroplasty. Female gender, increasing age, ASA classification, operative time, or a history of diabetes, COPD, CHF, or history of a bleeding disorder are risk factors hospitalizations exceeding 24 hours


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 751 - 755
1 Jun 2006
Gerber C Lingenfelter EJ Reischl N Sukthankar A

We compared six patients with a mean age of 70 years (49 to 80) with severe bilateral, painful glenohumeral joint destruction who underwent a single-stage bilateral total shoulder replacement, with eight patients of mean age 61 years (22 to 89) who underwent bilateral total shoulder replacement in two stages, at a mean interval of 18 months (6 to 43). The overall function, pain and strength improved significantly in both groups. The subjective shoulder value, relative Constant score, active external rotation and the strength were improved significantly more in the single-stage group. Active elevation, abduction and overall function improved, significantly more in the single-stage group. Both the total duration of hospitalisation and the time off work per shoulder were substantially shorter in the single-stage group. The overall rate of complication was lower in the single-stage group. Our findings indicated that single-stage bilateral total shoulder replacement yielded significantly better clinical results with shorter hospitalisation and rehabilitation than staged replacement, and was not associated with any increase in complications


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 351 - 351
1 Jul 2008
Smit A Trail I Haines J Conlon R
Full Access

Although few published papers assess the results of revision total shoulder replacement for painful hemi-arthroplasty with a functional rotator cuff, surgical outcome is accepted as being poor. Our experience suggests that results are poor if a well-fixed humeral stem is revised to correct version, and if a non-functional rotator cuff is not alternatively managed. We identified fifteen patients with painful hemi-arthroplasty and a suspected functional rotator cuff that underwent revision total shoulder replacement at Wrightington hospital over a ten year period. The aetiology comprised osteoarthritis (seven), inflammatory arthritis (five), trauma (two) and avascular necrosis (one). The average time interval to revision surgery was 44.5 months. Humeral head size was up-sized in two and down-sized in seven cases at revision surgery. Three cases underwent iliac crest autografting for glenoid deficiency. Four cases underwent humeral stem revision for incorrect version. The average surgical time for primary total shoulder replacement at Wrightington hospital is 80 minutes while the average time for these revision total shoulder replacements was 105 minutes. Four patients had an unsatisfactory outcome according to Neer’s criteria due to an intra-operative greater tuberosity fracture (one), an intra-operative humeral shaft fracture (one) and a non-functional rotator cuff (two), one of which was revised to an extended head prosthesis with good outcome. Surgical time for revision and primary total shoulder replacement did not differ significantly if humeral stem revision or glenoid augmentation was not indicated. Oversized humeral head components may cause pain due to overstuffing the joint and soft tissues. Revision total shoulder replacement for hemi-arthroplasty with incorrect prosthetic version cannot guarantee an improved outcome. Significant glenoid deficiencies can be effectively managed by iliac crest bone grafting at revision total shoulder replacement. Rotator cuff deficient patients should be managed with alternative prostheses


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 329 - 330
1 Jul 2011
Jahoda D Pokorny D Barták V Hromádka R Landor I Sosna A
Full Access

The infected total shoulder arthroplasty is not a frequent finding at the present time, the necessity of treating this complication may become more urgent with the continually increasing number of arthroplasty procedures performed. From 1992 till the beginning of 2005, eleven patients were treated for infected total shoulder arthroplasty. An acute infection occurred in one patient (9 %), subacute in three (27 %) and late in seven patients (64 %). The average period between the primary operation and infection manifestation was 19.3 months. The group of 181 patients operated on for shoulder replacement between 1992 and 2005 was evaluated, and a deep infection of total shoulder arthroplasty was found in 11 patients (2.2 %). An antibiotic therapy alone was sufficient to eradicate the infeciton in only 20 % of the infected patients, but these showed good Constant scores (average, 42 points). Revision surgery, debridement and irrigation drainage had a low success rate (33 %) and good Constant scores (average, 45 points) in the cured patients. A two-stage exchange was 100 % successful but had a poor outcome, with an average Constant score of 26 points. However, a two-stage exchange involving a spacer had both 100 % success rate and a good outcome with an average Constant score of 49 points. On statistical evaluation using the unpaired t-test, there was a significant difference in the Constant scores (T 4.35 p=0.005) between the patients undergoing exchange arthroplasty with (n=40) and without (n=4) the spacer. Poor function scores after resection arthroplasty are not surprising, because a sharp residual proximal humerus is likely to irritate soft tissues and, in addition, it is not possible to reconstruct a rotator cuff to match it. Comparing the results of one-stage with two-stage reimplantation is a complex issue. Attention should be paid to a relationship between the methods routinely used to treat an infected total shoulder arthroplasty and those preferred by the given hospital for treatment of other joints. If the therapy is well established in that hospital and gives good long-term results, it is optimal to use it also for the treatment of infected total shoulder arthroplasty. The method of treating infected total shoulder arthroplasty is not different from other big joint therapies. The use of a spacer will allow us to remodel soft tissues satisfactorily even after extensive debridement. The functional results of treatment involving a spacer are significantly better


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 24 - 24
2 Jan 2024
Nolan L Mahon J Mirdad R Alnajjar R Galbraith A Kaar K
Full Access

Total shoulder arthroplasty (TSA) and Reverse Total shoulder arthroplasty (RSA) are two of the most performed shoulder operations today. Traditionally postoperative rehabilitation included a period of immobilisation, protecting the joint and allowing time for soft tissue healing. This immobilisation period may significantly impact a patient's quality of life (Qol)and ability to perform activities of daily living (ADL's). This period of immobilisation could be safely avoided, accelerating return to function and improving postoperative QoL. This systematic review examines the safety of early mobilisation compared to immobilisation after shoulder arthroplasty focusing on outcomes at one year. Methods. A systematic review was performed as per the PRISMA guidelines. Results on functional outcome and shoulder range of motion were retrieved. Six studies were eligible for inclusion, resulting in 719 patients, with arthroplasty performed on 762 shoulders, with information on mobilisation protocols on 736 shoulders (96.6%) and 717 patients (99.7%). The patient cohort comprised 250 males (34.9%) and 467 females (65.1%). Of the patients that successfully completed follow-up, 81.5% underwent RSA (n = 600), and 18.4% underwent TSA (n = 136). Overall, 262 (35.6%) patients underwent early postoperative mobilisation, and 474 shoulders were (64.4%) immobilised for a length of time. Immobilised patients were divided into three subgroups based on the period of immobilisation: three, four, or six weeks. There were 201 shoulders (27.3%) immobilised for three weeks, 77 (10.5%) for four weeks and 196 (26.6%) for six weeks. Five of the six manuscripts found no difference between clinical outcomes at one year when comparing early active motion versus immobilisation after RSA or TSA. Early mobilisation is a safe postoperative rehabilitation pathway following both TSA and RSA. This may lead to an accelerated return to function and improved quality of life in the postoperative period


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis. Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 970 - 974
1 Jul 2010
Foruria AM Sperling JW Ankem HK Oh LS Cofield RH

This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical complications, radiographs, the need for revision surgery, and implant and patient survival. A total of 27 patients had an ASA classification of III or IV and medical abnormalities were common. Of the 13 shoulders with bony deficiency of the glenoid, nine required grafting. The duration of hospital stay was prolonged and blood transfusions were common. There were no peri-operative deaths. The mean follow-up was for 5.5 years (2 to 12). Pain was significantly reduced (p < 0.001) and movement improved in active elevation and both external and internal rotation (p < 0.001). Using the Neer scale for assessing outcome, 40 (80%) shoulders had an excellent or satisfactory result. There were medical or surgical complications in 17 cases. Four shoulders developed radiological evidence of loosened glenoid components, and three of these had a poor outcome. Three other shoulders required revision, two for instability. By the time of this review 39 of the patients had died from unrelated causes at a mean of 7.5 years (0.8 to 16.4) after surgery. Total shoulder replacement is a relatively effective treatment in this elderly group of patients. However, there is a requirement for more intense patient care in the peri-operative period, and non-fatal medical or surgical complications are common. Most of these elderly patients will have a comfortable functional shoulder for the rest of their lives


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 107 - 107
1 Mar 2017
Reiner T Bader N Panzram B Kretzer J Zeifang F
Full Access

Purpose. Total shoulder arthroplasty (TSA) has become a successful treatment option for degenerative shoulder disease. With the increasing incidence in primary TSA procedures during the last decades, strategies to improve implant longevity become more relevant. Implant failure is mainly associated with mechanical or biological causes. Chronic inflammation as a response to wear particle exposure is regarded as a main biological mechanism leading to implant failure. Metal ions released by fretting and corrosion at modular taper connections of orthopedic implants can cause cell-mediated hypersensitivity reactions and might lead to aseptic loosening. Modularity is also commonly used in total shoulder replacement. However, little is known about metal ion exposure in patients following TSA. The objective of this study was to determine in-vivo blood metal ion levels in patients after TSA and to compare blood metal ion levels to control subjects without metal implants. Methods. A total of 19 patients with anatomical total shoulder prosthesis (TSA group) and 20 patients with reverse total shoulder prosthesis (RSA group) who underwent unilateral total shoulder replacement at our hospital between March 2011 and December 2014 with no other metal implant or history of environmental metal ion exposure were recruited for analysis of blood metal ion concentrations of cobalt (Co), chromium (Cr) and titanium (Ti) at a mean follow-up period of 2.3 years (0.7–4.3). For comparison of metal ion concentrations blood samples were obtained in a healthy control group of 23 subjects without metal implants. Ethical approval and informed consent of each patient were obtained for this study. Results. Median cobalt ion levels were 0.14µg/l (range 0.03–0.48) in the TSA group, 0.18 µg/l (0.10–0.66) in the RSA group and 0.11µg/l (0.03–0.19) in the control goup. Median chromium ion levels were 0.34µg/l (0.09–1.26) in the TSA group, 0.48µg/l (0.17–2.41) in the RSA group and 0.14µg/l (0.04–0.99) in the control goup. Median titanium ion levels were 0.86µg/l (0.10–1.64) in the TSA group, 1.31µg/l (0.75–4.52) in the RSA group and 0.62µg/l (0.32–2.14) in the control goup. There was a statistically significant difference in chromium and titanium ion concentrations between both study groups and the control group (see figure 1–3). Conclusion. Patients with unilateral total shoulder replacement demonstrated elevated blood metal ion concentrations. Median blood metal ion levels were higher in the RSA group compared to the TSA group, which could be attributable to the modularity of the reverse total shoulder system. However, overall metal ion levels were relatively low compared to those seen in patients with metal-on-metal total hip replacements. The role of local metal ion exposure in the development of aseptic loosening or hypersensitivity reactions associated with total shoulder arthroplasty should be further investigated. For figures/tables, please contact authors directly.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 639 - 639
1 Jun 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 125 - 125
1 May 2016
Pauzenberger L Heuberer P Laky B Kriegleder B Anderl W
Full Access

Background. Tranexamic acid is an antifibrinolytic drug that has been shown to successfully reduce postoperative blood loss in total knee and hip arthroplasty. However, the efficacy of TXA following total shoulder arthroplasty has not been reported. Purpose. The purpose of the present study was to evaluate the impact of intravenous TXA on postoperative blood loss and transfusion rates in total shoulder reconstruction. Methods. Between July and December 2014, 50 patients scheduled for primary total shoulder arthroplasty of the shoulder were included in this blinded, randomized study. Patients received either 1000mg intravenous TXA within thirty minutes before skin incision and another 1000mg intravenously administered TXA during wound closure (group 1), or a placebo (group 2). The perioperative blood loss and the rate of blood transfusions were analyzed. Results. Early postoperative blood loss was 80.0±105.5ml in the TXA group (group 1), and 202.1±195.8ml in the placebo group (group 2). The administration of blood products was not necessary during the study period. Conclusion. The administration of intravenous tranexamic acid significantly reduced the postoperative blood loss following total shoulder arthroplasty


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 120 - 120
1 Nov 2021
Gregori P Singh A Harper T Franceschi F Blaber O Horneff JG
Full Access

Introduction and Objective. Total shoulder replacement is a common elective procedure offered to patients with end stage arthritis. While most patients experience significant pain relief and improved function within months of surgery, some remain unsatisfied because of residual pain or dissatisfaction with their functional status. Among these patients, when laboratory workup eliminates infection as a possibility, corticosteroid injection (CSI) into the joint space, or on the periprosthetic anatomic structures, is a common procedure used for symptom management. However, the efficacy and safety of this procedure has not been previously reported in shoulder literature. Materials and Methods. A retrospective chart review identified primary TSA patients who subsequently received a CSI into a replaced shoulder from 2011 – 2018 by multiple surgeons. Patients receiving an injection underwent clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to CSI. Demographic variables were recorded, and a patient satisfaction survey assessed the efficacy of the injection. Results. Of the 43 responders, 48.8% remembered the injection. The average time from index arthroplasty to injection was median 16.8 months. Overall, 61.9% reported decreased pain, 28.6% reported increased motion, and 28.6% reported long term decreased swelling. Improvement lasted greater than one month for 42.9% of patients, and overall 52.4% reported improvement (slight to great) in the shoulder following CSI. No patient developed a periprosthetic joint infection (PJI) within 2 years of injection. Conclusions. This study suggests that certain patients following TSA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out conditions unlikely to improve long term from a CSI. Given these findings, further study in a large, prospective trial is warranted to fully evaluate the benefits of CSI following TSA


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 454 - 460
1 Apr 2019
Lapner PLC Rollins MD Netting C Tuna M Bader Eddeen A van Walraven C

Aims. Few studies have compared survivorship of total shoulder arthroplasty (TSA) with hemiarthroplasty (HA). This observational study compared survivorship of TSA with HA while controlling for important covariables and accounting for death as a competing risk. Patients and Methods. All patients who underwent shoulder arthroplasty in Ontario, Canada between April 2002 and March 2012 were identified using population-based health administrative data. We used the Fine–Gray sub-distribution hazard model to measure the association of arthroplasty type with time to revision surgery (accounting for death as a competing risk) controlling for age, gender, Charlson Comorbidity Index, income quintile, diagnosis, and surgeon factors. Results. During the study period, 5777 patients underwent shoulder arthroplasty (4079 TSA, 70.6%; 1698 HA, 29.4%), 321 (5.6%) underwent revision, and 1090 (18.9%) died. TSA patients were older (TSA mean age 68.4 years (. sd. 10.2) vs HA mean age 66.5 years (. sd. 12.7); p = 0.001). The proportion of female patients was slightly lower in the TSA group (58.0% vs 58.4%). The adjusted association between surgery type and time to shoulder revision interacted significantly with patient age. Compared with TSA patients, revision was more common in the HA group (adjusted-health ratio (HR) 1.214, 95% confidence interval (CI) 0.96 to 1.53) but this did not reach statistical significance. Conclusion. Although there was a trend towards higher revision risk in patients undergoing HA, we found no statistically significant difference in survivorship between patients undergoing TSA or HA. Cite this article: Bone Joint J 2019;101-B:454–460


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1197 - 1200
1 Sep 2009
Betts HM Abu-Rajab R Nunn T Brooksbank AJ

We describe the longer term clinical and radiological findings in a prospectively followed series of 49 rheumatoid patients (58 shoulders) who had undergone Neer II total shoulder replacement. The early and intermediate results have been published previously. At a mean follow-up of 19.8 years (16.5 to 23.8) 14 shoulders survived. Proximal migration of the humeral component was associated with progressive loosening of the glenoid and humeral components, but was independent of the state of the rotator cuff at the time of operation. Despite these changes the range of movement was preserved. Most patients had little or no pain in the shoulder, could sleep undisturbed and could attend to personal hygiene and grooming


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 12 - 12
1 Aug 2017
Paterson P
Full Access

Arthroplasty implant modularity enables the surgeon to adapt the joint replacement construct to the patient's requirements, and often facilitates revision procedures. Total shoulder arthroplasty humeral modularity exists for many implant systems. Glenoid modularity with convertibility between anatomic and reverse shoulder arthroplasty is a recent development. Glenoid modularity is very useful when reconstructing glenoid bone deficiencies, or in providing a method for reverse shoulder arthroplasty joint lateralization. The live surgery will demonstrate a bio-reverse total shoulder arthroplasty (bRTSA). The humeral component is a modular press fit stem that can accommodate either reverse or anatomic metaphyseal components. The metaphyseal components can be exchanged without removing the stem or changing the humeral height. The glenoid base has three components. The trabecular titanium peg is available in two diameters, and four lengths for each diameter. The peg is fixed to a metal base plate via Morse taper. In revision settings, these components can be easily dissociated in situ, and a coring drill inserted over a well-fixed peg allows removal with minimal bone loss. Either a polyethylene component, or glenosphere can be attached to the baseplate to complete the glenoid construct. An innovative set of instruments have been developed to reliably prepare the glenoid and humeral bone graft. While the live surgery will demonstrate the grafting technique in a bRTSA, it can also be used to reconstruct glenoid deficiencies (eg, Walch B2). Implants have been developed to solve these issues, but often do so at the expense of very limited glenoid bone stock. Bone grafting actually creates a net increase in glenoid bone stock that may improve implant durability, and decrease revision complexity. The technique is quite simple and adds approximately ten minutes to operative time. I have used this technique for 5 years with no cases of graft failure