Advertisement for orthosearch.org.uk
Results 1 - 20 of 257
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty. Cite this article: Bone Joint J 2024;106-B(11):1321–1326


Bone & Joint Research
Vol. 13, Issue 5 | Pages 201 - 213
1 May 2024
Hamoodi Z Gehringer CK Bull LM Hughes T Kearsley-Fleet L Sergeant JC Watts AC

Aims. The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA). Methods. Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used. Results. A total of 19 studies met the inclusion criteria, investigating 28 possible prognostic factors. Most QUIPS domains (84%) were rated as moderate to high risk of bias. The quality of the evidence was low or very low for all prognostic factors. In low-quality evidence, prognostic factors with consistent associations with failure of TEA in more than one study were: the sequelae of trauma leading to TEA, either independently or combined with acute trauma, and male sex. Several other studies investigating sex reported no association. The evidence for other factors was of very low quality and mostly involved exploratory studies. Conclusion. The current evidence investigating the prognostic factors associated with failure of TEA is of low or very low quality, and studies generally have a moderate to high risk of bias. Prognostic factors are subject to uncertainty, should be interpreted with caution, and are of little clinical value. Higher-quality evidence is required to determine robust prognostic factors for failure of TEA. Cite this article: Bone Joint Res 2024;13(5):201–213


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims. There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). Methods. We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal. Results. The mean MEPS significantly improved from 47 (15 to 70) points preoperatively to 95 (70 to 100) points at final follow-up (p < 0.001). Complications were noted in six elbows (23%) in six patients, and of these, four with an ulnar neuropathy and one elbow with postoperative traumatic fracture required additional surgeries. There was no revision with implant removal, and there was no radiological evidence of loosening around the components. With any revision surgery as the endpoint, the survival rates up to 25 years were 78.1% (95% confidence interval 52.8 to 90.6) as determined by Kaplan-Meier analysis. Conclusion. The clinical outcome of primary unlinked TEA for young patients with RA was satisfactory and comparable with that for elderly patients. A favourable survival rate without implant removal might support the use of unlinked devices for young patients with this disease entity, with a caution of a relatively high complication rate regarding ulnar neuropathy. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Jt Open 2023;4(1):19–26


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 559 - 566
1 May 2022
Burden EG Batten T Smith C Evans JP

Aims. Arthroplasty is being increasingly used for the management of distal humeral fractures (DHFs) in elderly patients. Arthroplasty options include total elbow arthroplasty (TEA) and hemiarthroplasty (HA); both have unique complications and there is not yet a consensus on which implant is superior. This systematic review asked: in patients aged over 65 years with unreconstructable DHFs, what differences are there in outcomes, as measured by patient-reported outcome measures (PROMs), range of motion (ROM), and complications, between distal humeral HA and TEA?. Methods. A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on PROMs, ROM, and complications. PROMs and ROM results were reported descriptively and a meta-analysis of complications was conducted. Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42021228329). Results. A total of 29 studies met the inclusion and exclusion criteria. The mean Disabilities of the Arm, Shoulder and Hand questionnaire (DASH) score was 19.6 (SD 7.5) for HA and 38 (SD 11.9) for TEA and the mean abbreviated version of DASH was 17.2 (SD 13.2) for HA and 24.9 (SD 4.8) for TEA. The Mayo Elbow Performance Score was the most commonly reported PROM across included studies, with a mean of 87 (SD 5.3) in HA and 88.3 (SD 5) in TEA. High complication rates were seen in both HA (22% (95% confidence interval (CI) 5 to 44)) and TEA (21% (95% CI 13 to 30), but no statistically significant difference identified. Conclusion. This systematic review has indicated PROMs and ROM mostly favouring HA, but with a similarly high complication rate in the two procedures. However, due to the small sample size and heterogeneity between studies, strength of evidence for these findings is low. We propose further research in the form of a national randomized controlled trial. Cite this article: Bone Joint J 2022;104-B(5):559–566


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1312 - 1320
1 Nov 2024
Hamoodi Z Sayers A Whitehouse MR Rangan A Kearsley-Fleet L Sergeant J Watts AC

Aims. The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes. Methods. We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis. Results. A total of 3,891 primary TEAs were included. The annual incidence of TEA was between 0.72 and 0.82 per 100,000 persons before 2020 and declined to 0.4 due to a decrease in elective TEAs during the COVID-19 pandemic, with a slight recovery in 2022. Older patients, those of white ethnicity and females, were more likely to undergo TEA. Those who underwent elective TEA had a median wait of between 89 (IQR 41 to 221) and 122 days (IQR 74 to 189) in the years before 2021, and this increased to 183 days (IQR 66 to 350) in 2021. The number of TEAs performed by surgeons per annum remained unchanged, with a median of two (IQR 1 to 3). The median annual number of TEAs per region was three to six times higher than the median annual case load of the highest volume hospital in a region. Patients in the lowest socioeconomic group had a higher rate of serious adverse events and mortality (11%) when undergoing TEA for acute trauma. Conclusion. In England, TEA is more common in older age groups, those of white ethnicity, and females. The COVID-19 pandemic affected the incidence of elective TEA and waiting times, and the provision of TEA has not yet recovered. The Getting it Right First Time recommendation of centralizing services to one centre per region could result in up to a six-fold increase in the number of TEAs being performed in some centres. Cite this article: Bone Joint J 2024;106-B(11):1312–1320


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research. Methods. A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review. Results. A total of 362 studies met the inclusion criteria. Most were of total elbow arthroplasty (246; 68%), followed by radial head arthroplasty (100; 28%), distal humeral hemiarthroplasty (11; 3%), and radiocapitellar arthroplasty (5; 1%). Most were retrospective (326; 90%) and observational (315; 87%). The median sample size for all types of implant across all studies was 36 (interquartile range (IQR) 21 to 75). The median length of follow-up for all studies was 56 months (IQR 36 to 81). A total of 583 unique outcome descriptors were used and were categorized into 18 domains. A total of 105 instruments were used to measure 39 outcomes. Conclusion. We found that most of the literature dealing with elbow arthroplasty consists of retrospective observational studies with small sample sizes and short follow-up. Many outcomes have been used with many different instruments for their measurement, indicating a need to define a core set of outcomes and instruments for future research in this area. Cite this article: Bone Joint J 2022;104-B(10):1148–1155


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 31 - 31
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 – 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 56 - 56
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 - 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. Results. A total of 514 TEAs were included, of which 35 were revised. The five-year implant survival was 91%. Male sex, a higher BMI, and previous surgery to the same elbow showed a statistically significant association with revision (p < 0.036). Of the 35 revised implants, ten (29%) underwent a second revision. Conclusion. This study reports a five-year implant survival of TEA of 91%. Patient factors associated with revision are defined and can be used to optimize informed consent and shared decision-making. There was a high rate of secondary revisions. Cite this article: Bone Jt Open 2023;4(2):110–119


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims. The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. Methods. We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome. Results. A total of 38 studies including 2,118 TEAs were included in the study. The mean follow-up was 80.9 months (8.2 to 156). The implant failure and complication rates were 16.1% (95% confidence interval (CI) 0.128 to 0.200) and 24.5% (95% CI 0.203 to 0.293), respectively. Aseptic loosening was the most common mode of failure (9.5%; 95% CI 0.071 to 0.124). The mean postoperative ranges of motion (ROMs) were: flexion 131.5° (124.2° to 138.8°), extension 29.3° (26.8° to 31.9°), pronation 74.0° (67.8° to 80.2°), and supination 72.5° (69.5° to 75.5°), and the mean postoperative Mayo Elbow Performance Score (MEPS) was 89.3 (95% CI 86.9 to 91.6). The meta-regression analysis identified that younger patients and implants with an unlinked design correlated with higher failure rates. Younger patients were associated with increased complications, while female patients and an unlinked prosthesis were associated with aseptic loosening. Conclusion. TEA continues to provide satisfactory results for patients with RA. However, it is associated with a substantially higher implant failure and complication rates compared with hip and knee arthroplasties. The patient’s age, sex, and whether cemented fixation and unlinked prosthesis were used can influence the outcome. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Joint J 2020;102-B(8):967–980


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1198 - 1204
1 Sep 2008
Peden JP Morrey BF

This study reports our experience with total elbow replacement for fused elbows. Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically. A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful. Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 330 - 334
1 Mar 2007
Cesar M Roussanne Y Bonnel F Canovas F

Between 1993 and 2002, 58 GSB III total elbow replacements were implanted in 45 patients with rheumatoid arthritis by the same surgeon. At the most recent follow-up, five patients had died (five elbows) and six (nine elbows) had been lost to follow-up, leaving 44 total elbow replacements in 34 patients available for clinical and radiological review at a mean follow-up of 74 months (25 to 143). There were 26 women and eight men with a mean age at operation of 55.7 years (24 to 77). At the latest follow-up, 31 excellent (70%), six good (14%), three fair (7%) and four poor (9%) results were noted according to the Mayo elbow performance score. Five humeral (11%) and one ulnar (2%) component were loose according to radiological criteria (type III or type IV). Of the 44 prostheses, two (5%) had been revised, one for type-IV humeral loosening after follow-up for ten years and one for fracture of the ulnar component. Seven elbows had post-operative dysfunction of the ulnar nerve, which was transient in five and permanent in two. Despite an increased incidence of loosening with time, the GSB III prosthesis has given favourable mid-term results in patients with rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1416 - 1421
1 Oct 2010
Qureshi F Draviaraj KP Stanley D

Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1348 - 1351
1 Oct 2008
Rispoli DM Athwal GS Morrey BF

Ulnar neuropathy presents as a complication in 5% to 10% of total elbow replacements, but subsequent ulnar neurolysis is rarely performed. Little information is available on the surgical management of persistent ulnar neuropathy after elbow replacement. We describe our experience with the surgical management of this problem. Of 1607 total elbow replacements performed at our institution between January 1969 and December 2004, eight patients (0.5%) had a further operation for persistent or progressive ulnar neuropathy. At a mean follow-up of 9.2 years (3.1 to 21.7) six were clinically improved and satisfied with their outcome, although, only four had complete recovery. When transposition was performed on a previously untransposed nerve the rate of recovery was 75%, but this was reduced to 25% if the nerve had been transposed at the time of the replacement


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 53 - 53
1 Jan 2013
Thyagarajan D Amirfeyz R Blewitt N
Full Access

Total Elbow Replacements are indicated for pain and disability in patients with rheumatoid and osteoarthritis of the elbow. The quality of the cementation has been specifically studied and shown to be directly related to the clinical outcome and implant survival. Aim. The aim of our study is to radiologically assess and grade the cementation around the components following total elbow replacement (GSB 3 or Coonrad Morrey) in two groups of patients. Materials and methods. Group I underwent total elbow replacement using Heraeus cement gun with medium palacos viscosity cement and group 2 using Zimmer cement gun with simplex medium viscosity cement. Average age in Group 1 was 72.3 (range 67–88 yrs) and group 2 was 69 years (range 52–87 yrs). 3 Coonrad Morrey and 13 GSB 3 total elbow replacement were used in Group 1 and 2 Coonrad Morrey and 14 GSB 3 in group 2. The primary indication for surgery was osteoarthritis, rheumatoid arthritis, post traumatic arthritis and seronegative arthritis in both groups. The cementation was assessed radiologically using three grading system (Morrey, Gerber & Bristol). Results. In Group I (Heraeus) 14 had adequete cementation in both AP and lateral radiographs, 1 humeral and 1 ulna components on AP radiograph revealed marginal cementing. In Group 2 (Zimmer) 11 had adequete cementation in both AP and lateral radiographs, 1 humeral and 1 ulna on AP and 1 humerus and 3 ulna on lateral radiograph were 4 marginal. Conclusion. Precise application of cement during total elbow arthroplasty is an important factor in achieving good implant fixation. To achieve this, a proper ergonomic design of the cement gun is mandatory. From our study we conclude that there was a difference in quality of cementation between the two groups


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1369 - 1374
1 Oct 2005
Athwal GS Chin PY Adams RA Morrey BF

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192). Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early complications, the most frequent being nerve injury (25%). There were no infections or wound complications although 18 patients (90%) had radiotherapy, chemotherapy or both. The Coonrad-Morrey total elbow arthroplasty provides good relief from pain and a good functional outcome after resection of tumours of the elbow. The rates of complications involving local recurrence of tumour (25%) and nerve injury (25%) are of concern


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 69 - 69
1 Dec 2017
Girard M Arboucalot M Faraud A Delclaux S Bonnevialle N Delobel P Mansat P
Full Access

Aim. Infections after total elbow arthroplasty are more frequent than after other joint arthroplasties. Therapeutic management varies depending of the patient status, the time of diagnosis of the infection, the status of the implant as well as the remaining bone stock around the implants. Method. Between 1997 and 2017, 180 total elbow arthroplasties were performed in our department. Eleven (6%) sustained a deep infection and were revised. Infection occurred after prosthesis of first intention in 4 and after a revision procedure in 7. Etiologies were: rheumatoid arthritis in 6, trauma sequela in 4 and osteosarcoma in 1. There were 7 women and 4 men of 59 years on average (22–87). Delay between the prosthesis and the diagnosis of infection was 66 months (0.5–300). The infection was stated as acute (<3week) in one, subacute (between 3 week and 3 months) in 1, and chronic (>3 months) in 9. Isolated bacteria were: Staphylococcus (10), Streptococcus (1), P. acnes (1), and Proteus mirabilis (1). Infection were poly microbial in 2 cases. A simple lavage with debridement was performed in 3 cases (Group 1), a 2-stage revision in 4 (Group 2), and a definitive removal of the prosthesis in 4 (Group 3). Adapted antibiotics were prescribed for all patients during at least 6 weeks. Results. All patients were reviewed with 59 months average follow-up. Eight patients were cured of their infection thanks to the initial therapeutic strategy. For 2 patients of Group 2, infection reccurrency required a new surgical procedure with one simple lavage/debridement for one, and 3 lavage/debridement for the other making it possible to cure the infection. For one patient of Group 1, a failure of lavage/debridement required removal of the implants. The MEPS reached 72 points: 67 points for patients of Group 1, 76 points for patients of Group 2, and 74 points for patients of Group 3. Complication rate was 36% (4): 2 ulnar nerve impairment with dysesthesia, one radial nerve palsy, and one humeral stem loosening. Conclusions. An adapted therapeutic strategy can allow suppression of the responsible bacteria after infection of total elbow arthroplasty. Sometimes, several procedures are necessary to obtain the cure. Better functional results were obtained when the prosthesis could be retained or replaced, but satisfactory results could also be obtained after resection arthroplasty when the humeral columns have been preserved to stabilize the joint


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1489 - 1497
1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims. The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications. Materials and Methods. We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy). Results. This study included a total of 679 TEAs for RA (n = 482) or post-traumatic conditions (n = 197). After exclusion, all of the TEAs included in this meta-analysis were cemented with linked components. Our analysis demonstrated that the RA group was associated with a higher risk of septic loosening after TEA (odds ratio (OR) 3.96, 95% confidence interval (CI) 1.11 to 14.12), while there was an increased risk of bushing wear, axle failure, component disassembly, or component fracture in the post-traumatic group (OR 4.72, 95% CI 2.37 to 9.35). A higher MEPS (standardized mean difference 0.634, 95% CI 0.379 to 0.890) was found in the RA group. There were no significant differences in arc of range of movement, DASH questionnaire, and risk of aseptic loosening, deep infection, perioperative fracture, or ulnar neuropathy. Conclusion. The aetiology of TEA surgery appears to have an impact on the outcome in terms of specific modes of implant failures. RA patients might have a better functional outcome after TEA surgery. Cite this article: Bone Joint J 2019;101-B:1489–1497


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 216 - 216
1 May 2006
zu Reckendorf GM Roux J Allieu Y
Full Access

Reconstruction of deficient bone stock during total elbow arthroplasty in rheumatoid arthritis represents a challenge for the surgeon. Fracture and osteolysis of the olecranon process is a very rare condition in rheumatoid arthritis. The consequence of a deficient olecranon is an instable and painful elbow. We report a case of successful olecranon reconstruction with bone graft associated to total elbow arthroplasty with a 8 years follow up and discuss surgical aspects. This case concerns a 44 years old woman with a very severe rheumatoid arthritis. She complains of pain and instability of her right elbow. X-rays show fracture and major osteolysis of the olecranon process with only some persistent bone at the insertion of the triceps tendon. The humeral condyles were subluxated posteriorly. We performed a total elbow replacement with a GSB3 implant and reconstruction of the olecranon with two cancellous iliac bone strut fixed by 2.7 diameter screws to the proximal ulna. The triceps tendon with remnant olecranon bone chips was secured to the bone graft by tension band wiring. Postoperatively, the elbow was immobilized for 3 weeks. With a follow up of more than 8 years the elbow is pain free with excellent function. The active range of motion of flexion – extension is 140° / −20°. The elbow is stable and triceps function is very satisfying authorizing the use of crutches. X-rays show good bony integration of the reconstructed olecranon process and no signs of loosening of the GSB3 implant. The literature concerning olecranon reconstruction during total elbow arthroplasty in rheumatoid patients is very poor. Kamineni and Morrey reported on one case of olecranon reconstruction with strut allograft in revision total elbow arthroplasty with an unsatisfying result. Their fixation technique was different. We prefer an autograft whenever it is possible and we recommend our fixation technique using screws and tension band wiring


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 348 - 348
1 Jul 2008
Ashmore A Gozzard C Blewitt N
Full Access

Aims: To review the results from a series of GSB III total elbow arthroplasties performed at an independent centre. Between 1996 and 2004 the senior author performed 58 total elbow arthroplasties in 44 patients (10 males, 34 females) using the GSB III implant. These were reviewed and the outcome assessed through the use of a patient-answered questionnaire and clinical and radiological review. Mean age was 65 (49 to 84 years). Indications for surgery included rheumatoid arthritis (46 elbows) and post-traumatic osteoarthritis (11 elbows). Mean F/up was 4.1 years (0.8 to 8.5 years). 4 patients had died (6 elbows) and 4 patients (4 elbows) were unavailable for review. 2 of the implants had been revised (1x aseptic loosening, 1x deep infection), leaving a total of 46 elbows available for review. The survival rate at a mean of 4 years was 98% with aseptic loosening as the endpoint. Complications included 1 case of intraoperative fracture and 1 persistent ulnar neuritis. Overall patient satisfaction was high. The mean Mayo Elbow Performance Score was 83 out of 100 (range, 34 to 100) and mean Liverpool Elbow Score was 8 out of 10 (range, 1 to 10). Conclusion: Previous studies of outcome following total elbow arthroplasty using the GSB III elbow prosthesis at independent centres have shown satisfactory results, but have looked at small groups of patients. Our results offer more robust data to show that the medium term outcome following total elbow arthroplasty using the GSB III prosthesis is satisfactory