Advertisement for orthosearch.org.uk
Results 1 - 20 of 88
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 245 - 245
1 Nov 2002
Smith P Gillies R Quo W Walsh W
Full Access

Introduction: A tibial tubercle osteotomy can be used in the exposure of severe articular deformity and the tight knee in total knee arthroplasty, especially revision surgery. This osteotomy has been popularised by Dr. L. Whiteside [1] who described transosseous wiring to secure the osteotomy following joint reconstruction. Other fixation techniques including the use of cables and screws may provide options for this technique. The current study exmained 3 different fixation methods for tibial tubercle osteotomy using an in-vitro sheep model. Materials and Methods: Tibial tubercle osteotomies (5 cm in length) were performed in ten adult sheep tibias. The osteotomies were fixed sequentially using circumferential Dall-Miles cables (Howmedica, Ritherford, NJ) (Fig. 1), transosseous wires and lastly 2 AO screws. Testing of each fixation configuration was performed using an MTS 858 Mini Bionix servo hydraulic testing machine (MTS Systems Corporation, USA). The loading regime used a cyclic 200 N load applied along the line of the patellar tendon with micromotion measured at the osteotomy and adjacent bone using optical sensors (MEL, Bahnhofstr, Germany). Data was analyzed using ANOVA. Micromotion at the end of the osteotomy fragment was recorded for 150 cycles for each tibia following reconstruction with cables, wires, and screws in succession. Results: Cable fixation provided the most stable construct followed by screws and wires respectively. Wire fixation had the greatest variation in micromotion (370 microns). The ovine tibia model provides a reproducible bone bed to evaluate different fixation strategies for tibial tubercle osteotomy. Clinically, differences may even be marked considering anatomic and bone quality issues as well as magnitude of the load that have not been addressed in this in-vitro study. Discussion: Fixation of the osteotmoy is an important surgical technique. Wolff et al. found that major complications related to the surgical technique occurred in 23% of the knees performed in 26 cases [2]. Reis et al. [3] observed fixation with 3 or 4 titanium screws was sufficient after a follow-up period of 18 months. Twenty-nine of the osteotomies healed primarily. One patient developed postoperative displacement of the tibial tubercle requiring additional screw and suture fixation. This study has shown that micromotion of a tibial tubercle osteotomy fixation in sheep is dependent upon fixation technique. Cables provided the most stable fixation compared to screws and wires in an ovine tibial model


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 442 - 442
1 Apr 2004
Southgate CRW Wootton JR
Full Access

Aim: A study to determine the results of tibial tubercle osteotomy in a series of revision and difficult primary total knee replacements. Method: A consecutive series of total knee replacements in which tibial tubercle osteotomy was performed were reviewed retrospectively. 18 revision knees and 5 primary knee replacements were identified. All of the operations performed were by the senior author. The technique was the same in all cases, involving 9cm osteotomy with screw fixation. In cases with marked restricted flexion and patella baja, the tubercle was deliberately moved proximally to gain length in the extensor mechanism. Results: All osteotomies had united by 8–12 weeks as assessed on a lateral radiograph. Range of movement increased on average 45° in the revisions, and by 60° in the primaries. An active extensor lag in 4 cases (all deliberate proximalisations) post operatively which all recovered. 5 patients underwent MUA for stiffness at 12 weeks. Conclusion: Tibial tubercle osteotomy allows predictable extensile exposure in primary and revision total knee replacement. It also allows lengthening of a contracted extensor mechanism. Union rate was excellent and complications low. It allows preservation of the quadriceps mechanism and a normal post-operative rehabilitation


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 278 - 278
1 Mar 2004
Southgate C Wootton J
Full Access

Aim: The purpose of this study was to determine the long-term results of tibial tubercle osteotomy in a series of revision and difþcult primary total knee replacements. Method: A consecutive series of total knee replacements in which tibial tubercle osteotomy was performed were reviewed retrospectively. 18 revision knees and 5 primary knee replacements were identiþed. All of the operations performed were by the senior author. The technique was the same in all cases, involving 9cm osteotomy with screw þxation. In cases with marked restricted ßexion and patella baja, the tubercle was deliberately moved proximally to gain length in the extensor mechanism. In 3 revisions the index component had a porous in-growth stem. The osteotomy facilitated explantation. Results: All osteotomies had united by 8–12 weeks. Range of movement increased on average 45û in the revisions, and by 60û in the primaries. An active extensor lag in 4 cases (all deliberate proximalisations) post operatively which all recovered.5 patients underwent MUA for stiffness at 12 weeks. Conclusion: Tibial tubercle osteotomy allows predictable extensile exposure in primary and revision total knee replacement. It also allows lengthening of a contracted extensor mechanism. Union rate was excellent and complications low. It allows preservation of the quadriceps mechanism and a normal postoperative rehabilitation


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 11 - 11
1 May 2015
Punwar S Fick D Khan R
Full Access

We identified 26 tibial tubercle osteotomies (TTOs) performed in 23 revision knee arthroplasties between 2009 and 2013. Average age at last operation was 66 (33–92). Mean follow-up period was 14 months (3–33). Eleven TTOs were performed in 10 knees for single stage revisions and 15 TTOs were performed in 13 knees for 2 stage revisions in the setting of deep infection. In this infected subset 11 patients had a TTO performed at the first stage. This osteotomy was left unfixed to avoid leaving metalwork in a potentially contaminated wound, reopened, and then definitively secured with screws at the second stage. Our technique involves fashioning a long 7×1cm tibial tuberosity osteotomy without a proximal step-cut. All osteotomies united with no fractures. Minor proximal migration was noted in one case associated with screw loosening. There was no proximal migration noted in the 2 stage cases where the osteotomy had been left initially unfixed. There were no extensor lags. We conclude that TTO is a safe and reproducible procedure when adequate exposure cannot be obtained in revision knee arthroplasty. In 2 stage revisions sequential osteotomies does not decrease union rates and leaving the osteotomy unfixed after the first stage does not cause any issues


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 23 - 23
1 Jul 2022
Frame M Hauck O Newman M
Full Access

Abstract. Introduction. Tibial tubercle osteotomy (TTO) is a complex surgical procedure with a significant risk of complications, which include nonunion and tibial fracture. To determine whether an additional suture tape augmentation can provide better biomechanical stability compared with standard screw fixation. Methods. Five matched pairs of human cadaveric knees were divided into 2 groups: the first group underwent standard TTO fixation with 2 parallel screws. The second group underwent a novel fixation technique, in which a nonabsorbable suture tape (FiberTape) in a figure-of-8 construct was added to the standard screw fixation. Tubercular fragment migration of >50% of the initial distalization length was defined as clinical failure Tubercular fragment displacement during cyclic loading and pull-to-failure force were recorded and compared between the 2 groups. Results. The augmented group showed less cyclic tubercular fragment displacement after every load level compared with the standard group, with statistically significant differences starting from 500 N (P < .05; power > 0.8). Mean ± standard deviation tubercular fragment displacement at the end of cyclic loading was 2.56 ± 0.82 mm for the augmented group and 5.21 ± 0.51 mm for the standard group. Mean ultimate failure load after the pull-to-failure test was 2475 ± 554 N for the augmented group and 1475 ± 280 N for the standard group. Conclusion. The specimens that underwent suture tape augmentation showed less tubercular fragment displacement during cyclic loading and higher ultimate failure forces compared with those that underwent standard screw fixation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 104 - 104
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective. Difficult primary total knee arthroplasty (TKA) and revision TKA are high demanding procedures. Joint exposure is the first issue to face off, in order to achieve a good result. Aim of this study is to evaluate the clinical and radiological outcomes of a series of patients, who underwent TKA and revision TKA, where tibial tubercle osteotomy (TTO) was performed. Materials and Methods. We retrospectively reviewed a cohort of 79 consecutives TKAs where TTO was performed, from our Institution registry. Patients were assessed clinically and radiographically at their last follow-up (mean, 7.4 ± 3.7 years). Clinical evaluation included the Knee Society Score (KSS), the pain visual analogue scale (VAS), and range of motion. Radiological assessment included the evaluation of radiolucent lines, osteolysis, cortical bone hypertrophy, time of bone healing of the TTO fragment, and the hardware complication. Results. KSS raised from 40.7 ± 3.1 to 75 ± 4.3 (p < 0.0001). Knee flexion increased from 78.7 ± 9.9° to 95.0 ± 9.5° (p < 0.0001), and VAS improved from 7.9 ± 0.9 to 3.8 ± 1 (p < 0.0001). No signs of loosening or evolutive radiolucency lineswere found. Osteolytic areas around the stem were detected. No significant association was found between the implant design and the outcomes, while aseptic loosening showed significantly better results. Complications were: 4 painful hardware, 3 late periprosthetic infections, 1 extension lag of 5°, and 3 flexion lag. Conclusions. Our experience suggests the use of TTO to improve the surgical approach in difficult primary TKA or revision TKA. A strict surgical technique leads to good results with low risk of complications


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 25 - 25
1 Mar 2013
Bruni D Iacono F Presti ML Sharma B Raspugli G Marcacci M
Full Access

INTRODUCTION. Conventional surgical exposures are usually inadequate for 2-stage revision knee replacement ofinfected implants. Reduced range of motion, extensor mechanism stiffness, peripatellar contracture and soft tissue scarring make patellar eversion difficult and forced eversion places the integrity of the extensor mechanism at risk. On the contrary, a wide exposure is fundamental to allow complete cement spacer removal, soft tissue balancing, management of bone loss and reimplantation without damaging periarticular soft tissues. OBJECTIVES. To compare the long-term clinical, functional and radiographic results and the reinfection rate of the quadriceps snip approach and the tibial tubercle osteotomy in 2-stage revision knee replacement performed for septic loosening of the primary implant. METHODS. In our department, 87 patients had a 2 stage revision knee replacement for septic loosening of the primary implant between 1996 and 2008. In all patients, first stage consisted of primary implant removal, extensive soft tissue debridement and positioning of a static antibiotic loaded cement spacer. The timing for reimplantation was decided basing on negative clinical and laboratory (ESR, CRP) signs and negative Leukoscan results. For reimplantation, a quadriceps snip was used in patients with an intraoperative flexion >90° (Group A) while a tibial tubercle osteotomy (Group B) was used in patients with an intraoperative flexion <90°. RESULTS. At observation point, 4 patients died for reasons unrelated to surgery, leaving 42 patients in Group A and 41 in Group B. We had a total amount of 10 recurrent infections (11%) after reimplantation, 7 patients in Group A and 3 patients in Group B (p<0.005). Patients with a reinfection in Group A were treated with a knee fusion in 4 cases, a rerevision in 2 cases and an amputation above the knee in 1 case, while all those with a reinfection in Group B had a knee fusion. According to HSS score, 11 patients were rated as Excelent/Good in Group A and 9 patients in Group B (p=n.s.). Three patients had a major complication in Group A and 0 patients in Group B (p=0.005). No differences were found between the two groups regarding range of motion and subjective satisfaction. CONCLUSION. Tibial tubercle osteotomy is a safe procedure to obtain a wide exposure in 2-stage revision knee replacement performed for septic loosening of the primary implant and it is effective in reducing reinfection rate without compromising clinical results and range of motion


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 180 - 185
1 Feb 2007
Koëter S Diks MJF Anderson PG Wymenga AB

An abnormal lateral position of the tibial tuberosity causes distal malalignment of the extensor mechanism of the knee and can lead to lateral tracking of the patella causing anterior knee pain or objective patellar instability, characterised by recurrent dislocation. Computer tomography is used for a precise pre-operative assessment of the tibial tubercle-trochlear groove distance. A distance of more than 15 mm is considered to be pathological and an indication for surgery in symptomatic patients.

In a prospective study we performed a subtle transfer of the tibial tuberosity according to the information gained from the pre-operative CT scan. This method was applied to two groups of patients, those with painful lateral tracking of the patella, and those with objective patellar instability. We evaluated the clinical results in 30 patients in each group. The outcome was documented at 3, 12 and 24 months using the Lysholm scale, the Kujala score, and a visual analogue pain score.

Post-operatively, all but one patient in the instability group who had a patellar dislocation requiring further surgery reported good improvement with no further subluxation or dislocation. All patients in both groups had a marked improvement in pain and functional score. Two patients sustained a tibial fracture six and seven weeks after surgery. One patient suffered a per-operative fracture of the tibial tubercle which later required further fixation.

If carefully performed, this type of transfer of the tibial tubercle appears to be a satisfactory technique for the treatment of patients with an increased tibial tubercle-trochlear groove distance and who present with symptoms related to lateral maltracking of the patella.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 478 - 485
1 Apr 2013
Naveed MA Ackroyd CE Porteous AJ

We present the ten- to 15-year follow-up of 31 patients (34 knees), who underwent an Elmslie-Trillat tibial tubercle osteotomy for chronic, severe patellar instability, unresponsive to non-operative treatment. The mean age of the patients at the time of surgery was 31 years (18 to 46) and they were reviewed post-operatively, at four years (2 to 8) and then at 12 years (10 to 15). All patients had pre-operative knee radiographs and Cox and Insall knee scores. Superolateral portal arthroscopy was performed per-operatively to document chondral damage and after the osteotomy to assess the stability of the patellofemoral joint. A total of 28 knees (82%) had a varying degree of damage to the articular surface. At final follow-up 25 patients (28 knees) were available for review and underwent clinical examination, radiographs of the knee, and Cox and Insall scoring. Six patients who had no arthroscopic chondral abnormality showed no or only early signs of osteoarthritis on final radiographs; while 12 patients with lower grade chondral damage (grade 1 to 2) showed early to moderate signs of osteoarthritis and six out of ten knees with higher grade chondral damage (grade 3 to 4) showed marked evidence of osteoarthritis; four of these had undergone a knee replacement. In the 22 patients (24 knees) with complete follow-up, 19 knees (79.2%) were reported to have a good or excellent outcome at four years, while 15 knees (62.5%) were reported to have the same at long-term follow-up. The functional and radiological results show that the extent of pre-operatively sustained chondral damage is directly related to the subsequent development of patellofemoral osteoarthritis.

Cite this article: Bone Joint J 2013;95-B:478–85.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 8 - 8
1 Oct 2015
Ahmad R Calciu M Jayasekera N Schranz P Mandalia V
Full Access

Patients with recurrent patella instability, who have an abnormal patellofemoral alignment (patella height or tibial tubercle-trochlear groove (TTTG) distance), benefit from tibial tubercle transfer along with medial patellofemoral ligament (MPFL) reconstruction. Between July 2008 and April 2013, 18 patients (21 knees) with recurrent patellar instability underwent combined MPFL reconstruction and tibial tubercle transfer. All patients had abnormal patellofemoral alignment in addition to MPFL insufficiency. 15 patients (16 knees) with a mean age of 24 years (16–41) had a mean follow up of 26 months (6–55). We assessed the outcome using KOOS, KUJALA, activity level and patient satisfaction scores. All patients had a stable patella. There was a significant improvement in outcome scores in 12 out of 15 patients. At final follow up KOOS score had improved from 68.25(44 to 93.9) to 77.05(48.8 to 96.4) and KUJALA score had improved from 63.3(41–88) to 78.06 (45 to 99). 9 patients showed excellent results and achieved at least a pre-injury level of activity. 4 of these had activity level better then preoperative level. 6 patients had a lower activity level than pre-injury (1 – ongoing physiotherapy, 1 – because of lack of confidence, and 4 – Life style modification). 14 patients were satisfied and happy to recommend this procedure. There were 3 postop complications, with 2 cases of stiffness and 1 case of non-union of the tibial tuberosity. Our prospective study has shown that restoration of tibial tubercle-trochlear groove index, Patella height and Medial Patellofemoral Ligament reconstruction yields good results in carefully selected patients.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 148 - 148
1 Mar 2008
Burnett R Maloney W Barrack R Ponzar M Clohisy J
Full Access

Purpose: Problem : Infection in TKA is a devastating yet common complication. 2-stage reimplant procedures are performed in the treatment of this condition. Purpose:To evaluate the clinical, radiographic, complications, and patient satisfaction results of 2nd stage reimplantation revision TKA with the use of a TTO. Technical aspects of TTO length, fixation, bypass, and complications are reported.

Methods: From 1996–2004 our database identified 25 revision TKA (12% of 206 revision TKA) performed using a TTO. In 20/25 cases the procedure was a 2nd stage reimplant. Demographics, infecting organism, Gustillo grade, clinical, radiographic, AORI defects, complications, patient satisfaction were evaluated prospectively. All patients were followed until radiographic union of the TTO.

Results: At a mean follow up of 22 mo(range,6–84) no patients were lost to follow-up. 24 (96%)TTO’s healed - 1 requiring revision ORIF. Prior to reimplantation, patients had undergone a mean of 3.3 prior knee surgeries(range,2–8). Prior extensor mechanism procedures had been performed in 43% of knees. Methicillin resistant staphylococcus was the infecting organism in > 50% of knees. 19 knees had a static cement spacer removed at revision. Time to 2nd stage reimplant was 39 weeks(range,15–68). Poor preop range of motion and stiffness (mean arc 430 , range 10–950) improved significantly postop (mean flexion 880 p< .05). 13 (56%) knees required an adjunctive extensor procedure at the time of TTO. TTO length averaged 8.8cm(range,8–10). Screws(15 knees), 2mm cables(6), wires(4) were used for TTO fixation. Mean stem bypass of the TTO was 63mm (−20 to 100). 21 (84%) patients were satisfied with the procedure, despite 8 knees(32%) requiring further surgery. 6 (24%) TTO complications occurred; 1 escape requiring fixation. All TTO’s had healed at recent follow up.

Conclusions: TTO is a useful procedure for exposure in 2nd stage revision TKA. TTO union is predictable(96%), despite technical complications. Recurrence of infection requiring further surgery did not compromise TTO results. Prior/concurrent extensor mechanism procedures were noted frequently.

Funding : Other Education Grant

Funding Parties : Wright Medical Technologies


Bone & Joint Open
Vol. 3, Issue 3 | Pages 268 - 274
21 Mar 2022
Krishnan H Eldridge JD Clark D Metcalfe AJ Stevens JM Mandalia V

Recognized anatomic variations that lead to patella instability include patella alta and trochlea dysplasia. Lateralization of the extensor mechanism relative to the trochlea is often considered to be a contributing factor; however, controversy remains as to the degree this contributes to instability and how this should be measured. As the tibial tuberosity-trochlear groove (TT-TG) is one of most common imaging measurements to assess lateralization of the extensor mechanism, it is important to understand its strengths and weaknesses. Care needs to be taken while interpreting the TT-TG value as it is affected by many factors. Medializing tibial tubercle osteotomy is sometimes used to correct the TT-TG, but may not truly address the underlying anatomical problem. This review set out to determine whether the TT-TG distance sufficiently summarizes the pathoanatomy, and if this assists with planning of surgery in patellar instability. Cite this article: Bone Jt Open 2022;3(3):268–274


We present 10–15 year follow-up of 33 patients who underwent Elmslie-Trillat osteotomy for severe patellar subluxation or dislocation. In the literature it has been reported that tibial tubercle osteotomy predisposes to subsequent patella-femoral arthritis, however it has never been documented if pre-existent knee chondral damage has any role in this development. In our group all patients had pre-op knee arthroscopy performed and extant of chondral damage was documented. We preformed an evaluation by long-term follow-up to determine weather pre-op chondral damage was the cause of subsequent osteoarthritis of patella-femoral joint. All patients were invited to attend outpatient clinic for clinical examination and knee radiographs and assessed by an independent research surgeon. Mean age at follow-up was 43 years and average follow-up was 10.5 years (range 10–15 years). 90% follow-up was achieved. Knee function was assessed by clinical scores (Lysholm knee score, American Knee Score, Oxford Knee score, Tegner and Insall knee scores) and three radiographs (AP, Lateral and Merchant views). Four patients had developed significant arthritis and underwent joint arthroplasty. Majority of patients reported good results with no further dislocation. However we noticed that extant of pre-op chondral damage was a significant factor in subsequent development of patella-femoral arthritis. We will present our data which is unique as no previous such long-term results have been reported for tibial tubercle transfers followed-up for more than 10 years and have pre-op arthroscopic documented chondral damage


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 862 - 866
1 Jun 2010
Hay GC Kampshoff J Kuster MS

The lateral subvastus approach combined with an osteotomy of the tibial tubercle is a recognised, but rarely used approach for total knee replacement (TKR). A total of 32 patients undergoing primary TKR was randomised into two groups, in one of which the lateral subvastus approach combined with a tibial tubercle osteotomy and in the other the medial parapatellar approach were used. The patients were assessed radiologically and clinically using measurement of the range of movement, a visual analogue patient satisfaction score, the Western Ontario McMasters University Osteoarthritis Index and the American Knee Society score. Four patients were lost to the complete follow-up at two years. At two years there were no significant differences between the groups in any of the parameters for clinical outcome. In the lateral approach group there was one complication due to displacement of the tibial tubercle osteotomy and two osteotomies took more than six months to unite. In the medial approach group, one patient had a partial tear of the quadriceps. There was a significantly greater incidence of lateral patellar subluxation in the medial approach group (3 of 12) compared with the lateral approach group (0 of 16) (p = 0.034), but without any apparent clinical detriment. We conclude that the lateral approach with tibial tubercle osteotomy is a safe technique with an outcome comparable with that of the medial parapatellar approach for TKR, but the increased surgical time and its specific complications do not support its routine use. It would seem to be more appropriate to reserve this technique for patients in whom problems with patellar tracking are anticipated


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims. The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process. Methods. This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous. Results. Of 41 questions and statements on patellar instability, none achieved unanimous consensus, 19 achieved strong consensus, 15 achieved consensus, and seven did not achieve consensus. Conclusion. Most statements reached some degree of consensus, without any achieving unanimous consensus. There was no consensus on the use of anchors in MPFL reconstruction, and the order of fixation of the graft (patella first versus femur first). There was also no consensus on the indications for trochleoplasty or its effect on the viability of the cartilage after elevation of the osteochondral flap. There was also no consensus on postoperative immobilization or weightbearing, or whether paediatric patients should avoid an early return to sport. Cite this article: Bone Joint J 2023;105-B(12):1265–1270


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims. Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. Methods. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties. Results. A total of 35/94 patients (37.2%) had spacer-related complications, of which 26/35 complications (74.3%) were because of mechanical failure of the spacer construct, while 9/35 (25.7%) were due to recurrence of infection. Risk factors for internal failure were a construct where the total intramedullary spacer length was less than twice the length of the central osseous defect (p = 0.009), where proximal or distal intraosseous spacer contact was < 10%, and after tibial tubercle osteotomy (p = 0.005). The incidence of spacer complications significantly increased the time to second stage: mean 157 days (42 to 458) in those without complications versus 227 days (11 to 528) with complications (p = 0.014). Conclusion. The failure rate of static antibiotic-loaded cement spacers is much higher than anticipated. Complications of the spacer significantly increased the time to second-stage revision. The risk of mechanical failure is significantly increased if the spacer is less than double the size of the segmental defect, or if inadequate reinforcement is inserted into the residual bone. These findings serve as a guide for surgeons to avoid mechanical complications with static spacers. Cite this article: Bone Joint J 2024;106-B(10):1067–1073


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 120 - 120
2 Jan 2024
Camera A Biggi S Capuzzo A Cattaneo G Tedino R Bolognesi G
Full Access

Fractures of the prosthetic components after total knee arthroplasty (TKA) are rare but dangerous complications, sometimes difficult to diagnose and to manage. Aim of this study is to evaluate the incidence of component breakage and its treatment in our single institution's experience. We retrospectively review our institution registry. From 605 revision knee arthroplasties since 2000 to 2018, we found 8 cases of component breakage, of these 3 belonged to UKA, and 5 belonged to TKA. The UKA fractures were all on the metal tibial component; while 4 TKA fractures were ascribed to the liner (2 Posterior-Stabilized designs and 2 constrained designs) and only one case was on the femoral component. For every patient a revision procedure was performed, in two cases a tibial tubercle osteotomy was performed, while in one case (where the fracture was of the post cam) an arthroscopy was performed prior to the arthrotomy. All of the UKA fractures were treated with a standard revision implant. As regard the TKA, 2 liner fractures were treated with the only liner exchange, while the other 2 liner fractures and the fracture of the metallic component were treated with total knee revision. No intra- and post-operative complications were found. Component breakage after TKA is a serious complication. Its treatment, always surgical, can hide pitfalls, especially if the timing is not correct; indeed apart from the revision of one or more components, the surgeons must address any issues of management of bone defect and ligamentous stability


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 75 - 75
1 Dec 2022
Rousseau-Saine A Kerslake S Hiemstra LA
Full Access

Recurrent patellar instability is a common problem and there are multiple demographic and pathoanatomic risk factors that predispose patients to dislocating their patella. The most common of these is trochlear dysplasia. In cases of severe trochlear dysplasia associated with patellar instability, a sulcus deepening trochleoplasty combined with a medial patellofemoral ligament reconstruction (MPFLR) may be indicated. Unaddressed trochlear pathology has been associated with failure and poor post-operative outcomes after stabilization. The purpose of this study is to report the clinical outcome of patients having undergone a trochleoplasty and MPFLR for recurrent lateral patellofemoral instability in the setting of high-grade trochlear dysplasia at a mean of 2 years follow-up. A prospectively collected database was used to identify 46 patients (14 bilateral) who underwent a combined primary MPFLR and trochleoplasty for recurrent patellar instability with high-grade trochlear dysplasia between August 2013 and July 2021. A single surgeon performed a thin flap trochleoplasty using a lateral para-patellar approach with lateral retinaculum lengthening in all 60 cases. A tibial tubercle osteotomy (TTO) was performed concomitantly in seven knees (11.7%) and the MPFLR was performed with a gracilis tendon autograft in 22%, an allograft tendon in 27% and a quadriceps tendon autograft in 57% of cases. Patients were assessed post-operatively at three weeks and three, six, 12 and 24 months. The primary outcome was the Banff Patellar Instability Instrument 2.0 (BPII 2.0) and secondary outcomes were incidence of recurrent instability, complications and reoperations. The mean age was 22.2 years (range, 13 to 45), 76.7% of patients were female, the mean BMI was 25.03 and the prevalence of a positive Beighton score (>4/9) was 40%. The mean follow-up was 24.3 (range, 6 to 67.7) months and only one patient was lost to follow-up before one year post-operatively. The BPII 2.0 improved significantly from a mean of 27.3 pre-operatively to 61.1 at six months (p < 0 .01) and further slight improvement to a mean of 62.1 at 12 months and 65.6 at 24 months post-operatively. Only one patient (1.6%) experienced a single event of subluxation without frank dislocation at nine months. There were three reoperations (5%): one for removal of the TTO screws and prominent chondral nail, one for second-look arthroscopy for persistent J-sign and one for mechanical symptoms associated with overgrowth of a lateral condyle cartilage repair with a bioscaffold. There were no other complications. In this patient cohort, combined MPFLR and trochleoplasty for recurrent patellar instability with severe trochlear dysplasia led to significant improvement of patient reported outcome scores and no recurrence of patellar dislocation at a mean of 2 years. Furthermore, in this series the procedure demonstrated a low rate (5%) of complications and reoperations


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 114 - 114
1 Jun 2018
Nam D
Full Access

Achievement of adequate exposure in revision total knee arthroplasty is critical as it reduces the surgical time, enhances the ability for both component removal and reconstruction, and avoids devastating complications such as extensor mechanism disruption. However, this can be challenging as prior multiple surgeries and limited mobility contribute to a loss of tissue elasticity, thickened capsular envelope, and peri-articular soft tissue adhesions. A thorough pre-operative assessment of a patient's past surgical history, comorbidities, pre-operative radiographs (i.e. the presence of severe patella baja), and physical examination including range of motion, prior incisions, and soft tissue pliability are useful in determining the appropriate surgical techniques necessary for a successful revision. A systematic approach to the ankylosed knee is critical. Most techniques are geared towards mobilization of the extensor mechanism to safely displace the patella for component exposure. The initial exposure should consist of a long skin incision, a subperiosteal medial release, and debridement of suprapatellar, medial, and lateral adhesions to the femoral condyles. A lateral capsular release can prove helpful in further mobilization of the extensor mechanism. When performing a medial parapatellar arthrotomy it's important to keep in mind further extensile exposure techniques that may be required. For example, the arthrotomy should not extend proximally into the vastus intermedius or rectus femoris in the event that a quadriceps snip technique is to be used as this can compromise the ability to repair this exposure. Despite a large exposure and release of adhesions, sometimes the extensor mechanism remains at risk of rupture and adequate visualization cannot be obtained. In this event, extensile exposures such as a quadriceps snip, quadriceps turndown or tibial tubercle osteotomy are considered. The location of the patella often dictates the best exposure option as severe patella baja may not be overcome with a proximally based release. The quadriceps snip is most commonly used and provides improved exposure without the necessity of modifying the patient's post-operative rehabilitation. In addition, it can be extended to a quadriceps turndown which vastly improves visualization, but at the expense of needing to immobilise the knee post-operatively. A tibial tubercle osteotomy can also be used and provides excellent exposure especially in the case of severe patella baja or when removal of a cemented tibial stem is required. It preserves the extensor muscles, but risks include increased post-operative wound drainage due to limited soft tissue coverage, failure of fixation, or fracture of the tibial tubercle fragment or tibial shaft. Exposure in revision total knee arthroplasty is critical. Fortunately, this can be reliably achieved with a systematic approach to the knee and through the use of several extensile exposures at the surgeon's discretion