The
Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented
Objectives. The objective of this study was to assess all evidence comparing the
Implant choice was changed from cemented
The
Thumb Carpometacarpal (CMC) arthritis is a common pathology of the hand. Surgical treatment with thumb reconstruction is well described. Retrospective outcomes have been described for multiple techniques, suggesting patient satisfaction with multiple different techniques. The
To determine if any notable differences between a cemented
Objective. To evaluate the volume of cases, causes of failure, complications in patients with a failed
Between March 1987 and March 1997, we performed a modified
The records of 107 patients with displaced subcaptial hip fractures treated by
Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the
Ten cases of
Hip fractures are injuries that affect not only the joint of an elderly person, but also the patient’s survival. Four surgical options are well supported in the orthopaedic literature: reduction with internal fixation, different types of unipolar hemiarthroplasty, bipolar hemiarthroplasty, and total hip arthroplasty. The aim of this study is to assess
Between 1987 and 2006 we performed a modified
Aims. This study aimed to compare the change in health-related quality
of life of patients receiving a traditional cemented monoblock Thompson
hemiarthroplasty compared with a modern cemented modular polished-taper
stemmed hemiarthroplasty for displaced intracapsular hip fractures. Patients and Methods. This was a pragmatic, multicentre, multisurgeon, two-arm, parallel
group, randomized standard-of-care controlled trial. It was embedded
within the WHiTE Comprehensive Cohort Study. The sample size was
964 patients. The setting was five National Health Service Trauma
Hospitals in England. A total of 964 patients over 60 years of age who
required hemiarthroplasty of the hip between February 2015 and March
2016 were included. A standardized measure of health outcome, the
EuroQol (EQ-5D-5L) questionnaire, was carried out on admission and
at four months following the operation. Results. Of the 964 patients enrolled, 482 died or were lost to follow-up
(50%). No significant differences were noted in EQ-5D between groups,
with a mean difference at four months of 0.037 in favour of the
Exeter/Unitrax implant (95% confidence interval (CI) 0.014 to 0.087,
p = 0.156), rising to 0.045 (95% CI 0.007 to 0.098, p = 0.09) when
patients who died were excluded. The minimum clinically important
difference for EQ-5D-5L used in this study is 0.08, therefore any
benefit between implants is unlikely to be noticeable to the patient.
There was no difference in mortality or mobility score. Conclusion. Allowing for the high rate of loss to follow-up, the use of the
traditional
The carpometacarpal joint of the thumb is one of the most common locations of degenerative arthritis. Surgical options include trapezio-metacarpal fusion, replacement or resection arthroplasty with or without interposition. We report the medium term results of a Modified
The records of 243 patients with
We have performed a prospective review of 590 consecutive patients treated for a displaced intracapsular femoral neck fracture with a
The case histories of 361 subcapital fractures of the femoral neck in 354 patients treated by primary replacement with the cemented
We performed a randomised prospective trial to compare the results of 27 cemented and 26 uncemented bipolar hemiarthroplasties in active patients with displaced subcapital fractures of the femoral neck. After a mean follow-up of 17 months, significantly more of the uncemented group were experiencing pain in the hip and using more walking aids than the patients in the cemented group. The incidence of postoperative complications, the early mortality rate and the operating time and blood loss were not significantly different. Using otherwise identical prostheses the early results were much better with a cemented