Advertisement for orthosearch.org.uk
Results 1 - 20 of 146
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 4 - 4
10 Oct 2023
Russell H Tinning C Raza A Duff S Preiss RA
Full Access

The Thompson hemiarthroplasty is a common treatment option for acute neck of femur fractures in the elderly population. Our department noted a significant number of patients returning with thigh pain, radiographic loosening and femoral osteolysis following cemented implantation of the titanium alloy version of the Thompson hemiarthroplasty. We are not aware of any previous reports documenting complications specific to the titanium Thompson implant and a retrospective cohort study was therefore initiated following clinical governance approval. 366 titanium alloy Thompson prostheses were implanted for hip fracture treatment between 2017 and 2020. As of February 2023, 6 of these have been revised at our hospital. 5 were revised for symptomatic femoral osteolysis and 1 presented with an acute periprosthetic fracture. All revised cases were determined to be aseptic. 32 living patients were excluded from recall on compassionate grounds due to permanent nursing home residence. 47 living patients were identified of which 33 attended for xray. 28 deceased and/or nursing home resident patients who had pelvis x-rays in the previous 12 months were also included in the analysis. Including the 6 index hips already revised, a total of 61 hip xrays were analysed, of which 19 hips (31.1%) showed radiographic evidence of femoral osteolysis or loosening. We conclude that there is a concerning incidence of femoral osteolysis and implant loosening associated with the titanium Thompson implant. We have discontinued use of the implant and reported our experience to the MHRA. We encourage other Scottish Health-Boards who use this implant to consider enhanced follow-up


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results. In total, 1,312 Thompson’s hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion. The Thompson’s stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson’s implant as a cost-effective option for frail hip fracture patients. Cite this article: Bone Jt Open 2022;3(9):710–715


Bone & Joint Research
Vol. 6, Issue 8 | Pages 506 - 513
1 Aug 2017
Sims AL Farrier AJ Reed MR Sheldon TA

Objectives. The objective of this study was to assess all evidence comparing the Thompson monoblock hemiarthroplasty with modular unipolar implants for patients requiring hemiarthroplasty of the hip with respect to mortality and complications. Methods. A literature search was performed to identify all relevant literature. The population consisted of patients undergoing hemiarthroplasty of the hip for fracture. The intervention was hemiarthroplasty of the hip with a comparison between Thompson and modular unipolar prostheses. Pubmed, Embase, CINAHL, Web of Science, PROSPERO and the Cochrane Central Register of Controlled Trials. The study designs included were randomised controlled trials (RCTs), well designed case control studies and retrospective or prospective cohort studies. Studies available in any language, published at any time until September 2015 were considered. Studies were included if they contained mortality or complications. Results. The initial literature search identified 4757 items for examination. Four papers were included in the final review. The pooled odds ratio for mortality was 1.3 (95% confidence Interval 0.78 to 2.46) favouring modular designs. The pooled odds ratio for post-operative complications was 1.1 (95% CI 0.79 to 1.55) favouring modular designs. Outcomes were reported at 12 or six months. These papers all contained potential sources of bias and significant clinical heterogeneity. Conclusion. The current evidence comparing monoblock versus modular implants in patients undergoing hemiarthroplasty is weak. Confidence intervals around the pooled odds ratios are broad and incorporate a value of one. Direct comparison of outcomes from these papers is fraught with difficulty and, as such, may well be misleading. A well designed randomised controlled trial would be helpful to inform evidence-based implant selection. Cite this article: A. L. Sims, A. J. Farrier, M. R. Reed, T. A. Sheldon. Thompson hemiarthroplasty versus modular unipolar implants for patients requiring hemiarthroplasty of the hip: A systematic review of the evidence. Bone Joint Res 2017;6:–513. DOI: 10.1302/2046-3758.68.BJR-2016-0256.R1


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 57 - 57
1 Mar 2017
Ul Islam S Carter P Fountain J Afzaal S
Full Access

Implant choice was changed from cemented Thompson to Exeter Trauma Stem (ETS) for treatment of displaced intra-capsular neck of femur fractures in University Hospital Aintree, Liverpool, United Kingdom (a major trauma center), following the NICE guidelines that advised about the use of a proven femoral stem design rather than Austin Moore or Thompson stems for hemiarthroplasties. The aim of our study was to compare the results of Thompson versus ETS hemiarthroplasty in Aintree. We initially compared 100 Thompson hemiarthroplasties that were performed before the start of ETS use, with 100 ETS hemiarthroplasties. There was no statistically significant difference between the two groups in terms of patients' demographics (age, sex and ASA grade), intra-operative difficulties/complications, post op medical complications, blood transfusion, in-patient stay and dislocations. The operative time was statistically significantly longer in the ETS group (p= .0067). Worryingly, the 30 days mortality in ETS group was more than three times higher in ETS group (5 in Thompson group versus 16 in ETS group. P= .011). To corroborate our above findings we studied 100 more consecutive patients that had ETS hemiarthroplasty. The results of this group showed 30 day mortality of 8 percent. However the operative time was again significantly longer (p= .003) and there was 18 percent conversion to bipolar hemiarthropalsty. Moreover there was statistically significant increased rate of deep infection (7%, p = .03) and blood transfusion (27%, p = .007). This we feel may be due to longer and more surgically demanding operative technique including pressurised cementation in some patients with significant medical comorbidities. Our results raise the question whether ETS hemiarthoplasty implant is a good implant choice for neck of femur fracture patients. Randomised control trials are needed to prove that ETS implant is any better than Thompson hemiarthroplasty implants in this group of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 949 - 950
1 Jul 2006
Lloyd JM Calder JDF

The Thompson hemiarthroplasty is a popular hip prosthesis. We present two case reports highlighting a significant alteration in the design of the implant which compromised the success of the operations. In recent years the manufacturing process of this prosthesis has changed, with a resultant increase in the volume of the stem of 10 ml. It is essential that manufacturers inform orthopaedic surgeons of any alteration in the design of the implant and supply compatible instrumentation to minimise surgical errors. Surgeons must remain vigilant when checking the compatibility of the trial and definitive prostheses


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 19 - 19
1 Mar 2021
Mazor A Glaris Z Goetz T
Full Access

Thumb Carpometacarpal (CMC) arthritis is a common pathology of the hand. Surgical treatment with thumb reconstruction is well described. Retrospective outcomes have been described for multiple techniques, suggesting patient satisfaction with multiple different techniques. The Thompson technique uses a slip of Abductor Pollicis Longus for suspension and interposition as well as excision of the trapezium. Retrospective outcomes suggest good patient satisfaction. We describe the improvement in Patient rated outcomes scores (PROS) and changes in pinch and grip strength in a prospectively collected cohort of patients treated with a modification of the Thompson technique. To assess changes in Patient-Rated Wrist Evaluation (PRWE) and Disabilities of the Arm, Shoulder, and Hand (QDASH) scores, as well as to determine the percentage of patients that surpassed the Minimal Clinically Important Difference (MCID) figure that has been described in the literature for these tests. In addition, measurements for evaluation of pinch and grip strength prior to surgery, at six, and at twelve months follow-up were done. Between June 2016 and February 2019, a consecutive prospective series of Thirty-seven LRTI procedures with APL suspension arthroplasty (Thompson technique) were performed on 34 patients with osteoarthritis of the thumb CMC joint (24 women / 13 men; age 63±8.553). All surgeries were performed by the senior surgeon. Data was collected as part of a wrist pain database. Patients failing conservative treatment and electing surgical management of thumb arthritis were enrolled into the database. Patients were evaluated pre-operatively with the PRWE and QDASH questionnaires and grip and pinch strength measurements, and postoperatively at 6 and 12 months. The MCID for QDASH and PRWE is 14 and will be evaluated at the same time points for each patient. Paired student T-test was used to determine differences in the means. Data are presented as mean ± SD unless stated otherwise. Differences with p<.05 were considered significant. Compared to the pre-operative assessment, at six months, the means of PRWE pain score and PRWE functional score decreased significantly (32.824 SD±10.721 vs. 19.265 SD±12.268 and 30.262 SD±10.050 vs. 16.431 SD± 9.697 respectively, n=34,, p<0.05). 69% of the patients surpassed the MCID of 14 six months after the surgery. In addition, QDASH mean score also dropped from 56.108 to 32.219 (SD± 21.375 n=32. p<0.05) at six months. At one year, 76% of the patients were above the MCID of 14. The mean scores of these three questionnaires did not show significant change between six and twelve months. Compared to the initial pre-operative assessment, we found no statistically significant difference in the means of grip strength, point pinch, and lateral key pinch at six and twelve months. Thumb reconstruction with APL suspension arthroplasty demonstrates significant improvement in pain and functionality. No significant improvement in grip and pinch strength is observed, even at one year postoperatively


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 135 - 135
1 May 2011
Parker M Spurrier E
Full Access

To determine if any notable differences between a cemented Thompson stem hemiarthroplasty and a cemented Exeter stem hemiarthroplasty (ETS), 200 patients with a displaced intracapsular fracture were randomised between the two prosthesis. Surviving patients were followed-up for one year by a nurse blinded to the treatment allocation. The mean age of patients was 84 years and 13% were male. There were no differences between groups for the length of surgery, need for blood transfusion or hospital stay. Implant related complications were three minor operative fractures of the femur in each group. Two patients in the Thompson group had dislocation of the prosthesis requiring revision surgery and one further patient in the Thompson group had late acetabular wear requiring conversion to a total hip replacement. One further patient in the Thompson group had cement retained in the acetabulum. In total therefore only three patients, all in the Thompson group, which required revision surgery. Easy of surgery was assessed subjectively by the surgeon and reported to be easier for the ETS group (p=0.0002). During follow-up there was no significant difference in the degree of residual pain between groups. Conclusions are that the cemented Exeter stem hemiarthroplasty has some advantages over the traditional cemented Thompson hemiarthroplasty


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 98 - 98
1 Jan 2013
Singh A Manning W Duffy P Scott S
Full Access

Objective. To evaluate the volume of cases, causes of failure, complications in patients with a failed Thompson hemiarthroplasty. Methods. A retrospective review was undertaken between 2005–11, of all Thompson implant revised in the trust. Patients were identified by clinical coding. All case notes were reviewed. Data collection included patients demographic, time to revision, reason for revision, type of revision implant, surgical time and technique, transfusion, complications, HDU stay, mobility pre and post revision,. Results. 23 patients were identified, age 81 years (range 76–90). male to female ratio was 2:21, 11 right and 12 left hip. Mean time to failure was 50 months (1–104 m) range, mean follow up post revision surgery 26 months (3–77). Reason for revision was dislocation in 3 patients (13%), femoral loosening 5 (21%), peri-prosthetic fracture 3 (13%), Infection 6 (26%) and acetabular erosion 6 (26%). There were six infected cases in the study which was all aspirated preoperatively off which only 4 were positive. All infected cases grew an organism from intra-operative specimens. (80% cases) were coagulase negative Staphylococcus aureus. 35% only positive on enrichment cultures. 4 infected Thompsons were revised successfully with 2 stage revisions. One patient died after 1. st. stage and another was able to mobilise after the first stage with a cement spacer and refused further surgery. Mean surgical time was 3.5 hours (range 2.5–5.5). HDU stay 1.3 days (range 0–6). 6 deaths in total, 3 unrelated, 3 post operative. Complications included 1 fracture requiring revision, 1 dislocation, 1 foot drop and 4 chest infection of which two patients died from this. Conclusion. We identified a revision rate of 1.2%, complication occurred in 43% of cases with a one year mortality of 26%. Failed Thompson revision surgery is rare, challenging and patient selection is important to reduce postoperative morbidity and mortality


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 992 - 995
1 Sep 2000
Hahn SB Lee WS Han DY

Between March 1987 and March 1997, we performed a modified Thompson quadricepsplasty on 20 stiff knees and followed the patients for a mean of 35 months (24 to 52). After the operation, the knee was immobilised in flexion and periodically extended. At the final follow-up, the mean active flexion was 113.5° (75 to 150). The final mean gain in movement was 67.6° (5 to 105). One patient had a deep infection which resolved after wound care and intravenous antibiotics. The modified Thompson quadricepsplasty with appropriate postoperative care can give good results


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 398 - 401
1 Nov 1977
Sikorski J Millar A

The records of 107 patients with displaced subcaptial hip fractures treated by Thompson's femoral head replacements have been reviewed to determine the mortality and certain aspects of systemic morbidity. Comparison was made with a group, matched exactly for age and sex, in which intertrochanteric fractures were treated by nail-plate fixation. The patients treated by Thompson's arthroplasty were further subdivided into two groups: one in which methylacrylic cement was used, and one in which it was not used. We found no difference in the mortality of the patients undergoing replacement arthroplasty and nail-plate fixation. Similarly there was no difference in the incidence of cerebrovascular incidents and myocardial infarction after operation. There was a higher incidence of transient cardiac failure following Thompson's arthroplasty. Hypotension during the operation occurred irrespective of whether cement was used; nor was the use of cement associated with increased mortality. However, it seems that methylacrylic cement does contribute to the cardiac failure that may occur after Thompson's arthroplasty


Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the Thompson implant when performing hip hemiarthroplasty and recommended surgeons consider using the anterolateral surgical approach over a posterior approach. Our objective was to review outcomes from a consecutive series of Thompson hip hemiarthroplasty procedures performed in our unit and to identify any factors predicting the risk of complications. 807 Thompson hip hemiarthroplasty cases performed between April 2008 and November 2013 were reviewed. 721 (89.3%) were cemented and 86 (10.7%) uncemented. 575 (71.3%) were performed in female patients. The anterolateral approach was performed in 753 (93.3%) and the posterior approach with enhanced soft tissue repair in 54 (6.7%). Overall, there were 23 dislocations (2.9%). Dislocation following the posterior approach occurred in 13.0% (7 of 54) in comparison to 2.1% (16 of 753) with the anterolateral approach (odds ratio (OR) 8.5 (95% CI 2.8 to 26.3) p < 0.001). Surgeon grade and patient history of cognitive impairment did not have a significant impact on dislocation rate. Patients were discharged home in 459 cases (56.9%), to a care home or other hospital in 273 cases (33.8%). 51.8% (338 of 653) returned home within 30 days. 75 died during their admission (9.3%). 30-day mortality was 7.1% and 1-year mortality was 16.6%. Intraoperative fracture occurred in 15 cases (1.9%) of which 14 were cemented. Superficial or deep infection occurred in 33 cases (4.1%). We recommend against the continued use of the posterior approach in hip hemiarthroplasty, as enhanced soft tissue repair did not reduce dislocation rates to an acceptable level. Our findings, however, demonstrate satisfactory results for patients treated with the Thompson hip hemiarthroplasty performed through an anterolateral approach. We suggest that the continued use of the Thompson implant in a carefully selected patient cohort is justifiable


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 3 | Pages 491 - 495
1 Aug 1963
Hesketh KT

Ten cases of Thompson's quadricepsplasty for stiffness of the knee after thigh injuries are discussed, with particular reference to points in the operation and after-treatment


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 169 - 169
1 Mar 2006
Benouziou A Koutsonas D Sakkas A Anastasiou E
Full Access

Hip fractures are injuries that affect not only the joint of an elderly person, but also the patient’s survival. Four surgical options are well supported in the orthopaedic literature: reduction with internal fixation, different types of unipolar hemiarthroplasty, bipolar hemiarthroplasty, and total hip arthroplasty. The aim of this study is to assess Thompson hemiathroplasty as a treatment for these lesions and their complications. Between January 1999 and September 2003, we treated 213 patients who suffered femoral neck fracture, 119 patients of them were treated with Thompson cemented prosthesis. The average age was 82.6 years. The average time between admission and surgery was 3.1 days. The time between surgery and discharge from hospital was 7 days on average. First year mortality after fracture was assessed (25%) and functional results were compared with the preoperative status. The mean follow-up was 36 months. Independence in daily activities before and after fracture compared according to a modified scored questionnaire, based on the lower extremity measure, which was easy to administer by telephone interview. Of the 96 patients that we contacted 48 were alive and available for follow-up. 11 patients (11.4%) had clinical and surgical complications. According to functional results 28.5% of the patients reached a score between 85 and 99 points (very good), 40.8% had a score between 55 and 84 points (good) and 18.4% had a fair outcome in postoperative time. We consider that Thompson hemiarthroplasty must remain as a surgical option in the treatment of femoral neck fractures in the elderly. The procedure provides rapid return to preoperative functional status for the majority of the patients (71.3% in the present study) with low surgical cost


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 217 - 221
1 Feb 2010
Hahn SB Choi YR Kang HJ Lee SH

Between 1987 and 2006 we performed a modified Thompson’s quadricepsplasty on 40 fracture-related stiff knees and followed the patients for a mean of 7.9 years (2 to 11.1). The factors affecting the final gain of movement were investigated. A total of 15 knees required lengthening of the rectus femoris. The mean flexion gain was 70.2° (42.3° to 112.5°). According to Judet’s criteria, the results were excellent in 30 knees, good in seven, and fair in three. The range of movement which was achieved intra-operatively was related to the gain of knee flexion on univariate analysis. Five patients had complications: deep infection in one, recurrent patellar dislocation in one, and rupture of the extensor mechanism in three. This modified technique gives satisfactory results. Achieving maximum knee flexion intra-operatively seems to be the most important factor in enhancing the outcome in patients with stiffness of the knee following fracture


Aims. This study aimed to compare the change in health-related quality of life of patients receiving a traditional cemented monoblock Thompson hemiarthroplasty compared with a modern cemented modular polished-taper stemmed hemiarthroplasty for displaced intracapsular hip fractures. Patients and Methods. This was a pragmatic, multicentre, multisurgeon, two-arm, parallel group, randomized standard-of-care controlled trial. It was embedded within the WHiTE Comprehensive Cohort Study. The sample size was 964 patients. The setting was five National Health Service Trauma Hospitals in England. A total of 964 patients over 60 years of age who required hemiarthroplasty of the hip between February 2015 and March 2016 were included. A standardized measure of health outcome, the EuroQol (EQ-5D-5L) questionnaire, was carried out on admission and at four months following the operation. Results. Of the 964 patients enrolled, 482 died or were lost to follow-up (50%). No significant differences were noted in EQ-5D between groups, with a mean difference at four months of 0.037 in favour of the Exeter/Unitrax implant (95% confidence interval (CI) 0.014 to 0.087, p = 0.156), rising to 0.045 (95% CI 0.007 to 0.098, p = 0.09) when patients who died were excluded. The minimum clinically important difference for EQ-5D-5L used in this study is 0.08, therefore any benefit between implants is unlikely to be noticeable to the patient. There was no difference in mortality or mobility score. Conclusion. Allowing for the high rate of loss to follow-up, the use of the traditional Thompson hemiarthroplasty in the treatment of the displaced intracapsular hip fracture shows no difference in health outcome when compared with a modern cemented hemiarthroplasty. Cite this article: Bone Joint J 2018;100-B:352–60


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 8 - 8
1 Apr 2012
Singh B Kewill S Hales P
Full Access

The carpometacarpal joint of the thumb is one of the most common locations of degenerative arthritis. Surgical options include trapezio-metacarpal fusion, replacement or resection arthroplasty with or without interposition. We report the medium term results of a Modified Thompson's suspensionplasty. The radial half of the APL tendon was looped around the FCR tendon to create the suspension. The remainder of the tendon is then used for interposition. We carried out a retrospective review of 50 patients (67 hands) who underwent this procedure from January 1999 to December 2005. There were 41 female (52 hands) and 9 male (15 hands). The average age at the time of surgery was 62 years (range 41 years – 79 years). The average follow up was 5.33 years (1-9 yrs). 22 patients also had a concurrent second procedure to the same thumb and a further three had a third procedure. The average PRWHE score was 25 (0 – 80) and the average DASH score was 40 (24 – 100). There were eight complications which included four persistent radial sided wrist pain. Two of these underwent tenotomy of FCR, whilst two responded to conservative measures. Two patients had symptoms related to scapho-trapezoid arthritis, which responded to an injection. One patient had superficial infection which settled with oral antibiotics, whilst another patient had early chronic regional pain syndrome. Overall the satisfaction rate was 90% with 48 patients (96%) willing to undergo the same procedure again. We conclude that the modified Thompson's suspensionplasty gives excellent medium term results


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 437 - 443
1 Nov 1975
Chan RN Hoskinson J

The records of 243 patients with Thompson prostheses for displaced femoral neck fractures have been studied. One hundred and seven prostheses were inserted through an anterior approach and 136 by a posterior approach. The short-term results and complications in these otherwise comparable groups are discussed. The infection rate of 18·5 per cent in the group operated upon by the posterior approach was thrice that after operations by the anterior route (6·5 per cent infected). Drained wounds had significantly less infection (6·3 per cent) compared with the undrained group (28 per cent infected). Other factors influencing the infection rate are discussed. The anterior approach offered greater stability. Of the twenty dislocations in the series, nineteen followed operations by the posterior approach. The mortality rate six weeks after operation was 6·5 per cent after the anterior approach and 20·6 per cent after the posterior approach. Statistical analysis significantly favours the anterior approach


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 168 - 169
1 Mar 2006
Hussain S Hawkins A Smith R
Full Access

We have performed a prospective review of 590 consecutive patients treated for a displaced intracapsular femoral neck fracture with a Thompson hemiarthroplasty. 113 patients had the prosthesis cemented, 477 had no cement. The outcome at 12 months was obtained for every patient still alive as regards to pain, mobility, re-operation rate and residential status. There was no significant difference between the 2 groups as regards pain (p = 0.482), decrease in mobility or re-operation rate (p = 0.168). The main determination of poor outcome was increasing age at time of injury and whether the patient was already in institutional care at the time of the injury. The use of cement had no bearing on outcome. This study is of clinical interest because patients who have undergone uncemented hemiarthroplasty have been shown to have similar out come to cemented hemiarthroplasty in terms of function. In addition possible but preventable complications associated with cementing can be minimized. We now believe there is no primary indication to cement the Thompsons hemiarthroplasty in this group of patients. There have been smaller studies looking at this, but we believe this to be the largest and most comprehensive to date


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 279 - 286
1 Aug 1976
D'Arcy J Devas M

The case histories of 361 subcapital fractures of the femoral neck in 354 patients treated by primary replacement with the cemented Thompson prosthesis were reviewed, and 156 survivors were seen at follow-up. The average age was eighty-one years. Three hundred and thirty fractures occurred in women and thirty-one in men. The antero-lateral approach to the hip was used at all operations because it allows immediate and unrestricted mobilisation after operation. It is considered that this method is the best treatment in the rehabilitation of elderly patients after high femoral neck fractures, because of its low morbidity and high success rate in returning the geriatric orthopaedic patient to independence. The results after an average of just over three years were available for 161 hips in 156 patients studied at follow-up. Of these, 132 (82 per cent) were satisfactory. Most of the unsatisfactory results were in patients under seventy-five years of age. Out of the whole group of 361 hips treated the important early complications were wound infections in seventeen hips 4-7 per cent), all of which resolved, and dislocation in seven hips (2 per cent). Forty-six patients (12-9 per cent) died during the first four weeks after operation, their average age being eighty-five. One hundred and seventy-one patients (47-4 per cent) were discharged from hospital within under four weeks of the operation. Acetabular erosion and loosening are shown to be the important later complications. Three patients had late sepsis


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 322 - 324
1 Mar 1991
Emery R Broughton N Desai K Bulstrode C Thomas T

We performed a randomised prospective trial to compare the results of 27 cemented and 26 uncemented bipolar hemiarthroplasties in active patients with displaced subcapital fractures of the femoral neck. After a mean follow-up of 17 months, significantly more of the uncemented group were experiencing pain in the hip and using more walking aids than the patients in the cemented group. The incidence of postoperative complications, the early mortality rate and the operating time and blood loss were not significantly different. Using otherwise identical prostheses the early results were much better with a cemented Thompson stem than with an uncemented Austin Moore stem