Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 82 - 82
1 Nov 2016
Goetz T Kilb B Okada M
Full Access

This is largest collection of outcomes of distal biceps reconstruction in the literature. 8 subjects prospectively measured pre and post reconstruction Strength deficit in patients with chronic tendon deficit is described. To describe outcomes for 53 chronic distal biceps reconstructions with tendon graft. Clinical outcomes as well as strength and endurance in supination and flexion are reported. To examine eight patients measured pre- and post-reconstruction. To identify deficit in supination and flexion in chronic reconstruction. 53 reconstructions of chronic distal biceps with tendon graft were carried out between 1999 and 2015. 26 subjects agreed to undergo strength testing after minimum one year follow up. Eight subjects were tested both before and after reconstruction. Primary outcomes were strength in elbow flexion and forearm supination. Strength testing of supination and flexion included maximum isokinetic power and endurance performed on a Biodex. Clinical outcomes measures included pre-operative retraction severity, surgical fixation technique, postoperative contour, range of motion, subjective satisfaction, SF-12, DASH, MAYO elbow score, ASES and pain VAS Non-parametric data was reported as median (interquartile range), while normally-distributed data was reported as mean with 95% Confidence Limits. Hypothesis testing was performed according to two-tailed, paired t-tests. Median time from index rupture to reconstructions 9.5 (range 3–108) months. Strength measurements were completed at a median follow-up time of 29 (range 12–137) months on 26 subjects. The proportion of patients that achieved 90% strength of the contralateral limb post-reconstruction was 65% (17/26) for peak supination torque, and 62% (16/26) for peak flexion torque. Supination and flexion endurance was 90% of the contralateral arm in 81% (21/26) and 65% (17/26) of subjects, respectively. Ten subjects (39%) achieved 90% strength of the contralateral arm on at least four of five strength tests. Eight of the 26 patients were evaluated pre- and post-surgery. As compared to the contralateral limb, chronic distal biceps rupture was found to have a mean [95%CI] deficit in peak supination torque of 31.0 [21.0, 42.9]% (p=0.002). Mean deficit in peak flexion torque of 34.2 [23.1, 45.4]% (p <0.001). Reconstruction resulted in an increase in peak supination torque of 33.5 [8.7, 58.3]% (p=0.0162), increase in peak flexion torque of 35.0 [6.4, 63.6]% (p=0.023), increase in isometric strength of 57.6 [36.1, 79.1]% (p<0.001), increase in supination endurance of 0.6 [-22.2, 23.4]% (p=0.668), and a decrease in flexion endurance of 4.8 [-23.3, 13.7](p=0.478). Ninety-six percent of the patients (25/26) were satisfied, or very satisfied with the overall outcome of the surgery, while median Mayo score post-reconstruction was 100 (range: 55–100). Chronic distal biceps tendon rupture results in less supination loss and greater flexion loss than previously reported. Reconstruction with tendon graft results in a significant, but incomplete recovery of peak supination and flexion torque, but no significant change in endurance. Clinical patient satisfaction with surgical outcomes is high


Purpose. To evaluate the results of quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with four fold Hamstring Tendon Graft using Transfix and Bioabsorbable Interference Screw Fixation. Study Design. Retrospective review. Methods. Sixty-five patients (66 knees) were retrospectively identified by chart review as having undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction, with four fold Hamstring Tendon Graft, using Transfix and Bioabsorbable Interference Screw Fixation. All patients underwent a minimum two-year follow-up. Results. Data were collected on 48 knees in 47 patients (73%) at an average 30.2 months (range 24 to 43) after surgery. Thirty-six patients (37 knees) returned for clinical evaluation (56% return) and subjective follow-up only was obtained in 11 patients (17%). The mean Lysolm knee score was 91 (range, 45 to 98), with a mean of 97 for the uninvolved knee. The mean Tegner activity score was 5.7 (range 3 to 7). The KT-1000 arthrometer mean side-to-side difference for manual maximum displacement was 2.03 mm (range -1 to 8). The mean International Knee Documentation Committee knee score was 83 (range 47 to 100). Patients who underwent associated partial meniscectomy or meniscal repair had significantly lower International Knee Documentation Committee scores than patients without associated procedures (P < 0.01). Conclusions. Quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation is comparable with other methods of anterior cruciate ligament reconstruction in terms of patient satisfaction, knee stability, and function


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 216 - 216
1 Jan 2013
Ahmad Z Wardale J Henson F Brooks R Tytherleigh-Strong G Noorani A Siddiqui N Rushton N
Full Access

Introduction

Rotator cuff tears remain a problem, with massive tears having a failure rate of repair reported of up to 60%, despite advances in surgical techniques. Tissue engineering techniques offers the possibility of regenerating damaged tendon tissue to a pre-injury state. We explore these techniques by implanting two novel tendon augmentation grafts with use of platelet rich plasma (PRP) in sheep.

Methods

A total of 24 sheep were operated on, with the infraspinatus being surgically cut from its attachment to the humeral head. Each tendon was repaired using suture anchors and an interpositional implant according to 4 groups: (1) Empty control, (2) Novel collagen fibre implant with PRP (3) A novel collagen sponge implant (4) and the collagen sponge with PRP. The sheep were killed at 12 weeks and the implant site harvested and its histology evaluated.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 10 - 10
3 Mar 2023
Brock J Jayaraju U Trickett R
Full Access

There is no consensus for the appropriate surgical management of chronic ulnar collateral ligament (UCL) injuries of the thumb. A systematic review of Pubmed, MEDLINE, EMBASE and ePub Ahead of Print was performed in accordance with Preferred Reporting of Items in Systematic Review and Meta-analysis (PRISMA) guidelines and formal protocol registered with PROSPERO. Two authors collated data from 10 studies that met strict inclusion criteria, using various surgical techniques in 131 thumbs. Results were heterogenous and metanalysis of results not possible. These data were, therefore, qualitatively assessed and synthesised. Bias was assessed using the ROBINS-I tool. Direct repair, reconstruction with free tendon or bone-tissue-bone grafts and arthrodesis all demonstrated favourable outcomes with Patient Reported Outcome Measures. Direct repair can be safely performed more than two months following injury, with a positive mean Disabilities of the Arm, Shoulder and Hand (DASH) score of 13.5 despite evidence of radiographic osteoarthritis. Arthrodesis should be considered in heavy manual laborers or those at risk of osteoarthritis as it provides significant reduction in pain (Mean Visual Analogue Score of 1.2) when compared to other methods. Free tendon grafting has been criticised for failure rates and poor functional grip strength, however collated analysis of 97 patients found a single graft rupture and mean grip strength of 97% (of the contralateral thumb). Bone-tissue-bone grafting was the least effective method across all outcome measures. Studies included were at high risk of bias, however, it can be concluded that delayed direct repair can be performed safely, while arthrodesis may benefit certain patient subgroups. New findings suggest poor efficacy of bone-tissue-bone grafts, but that free tendon grafting with palmaris longus are in fact safe with good restoration of grip strength. The optimal graft and configuration are yet to be determined for reconstructive methods


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 4 - 4
1 Dec 2022
Thatcher M Oleynik Z Sims L Sauder D
Full Access

Trapeziectomy with ligament reconstruction and tendon interposition (LRTI) with the flexor carpi radialis (FCR) tendon is one of the most common procedures for the treatment of thumb carpometacarpal (CMC) arthritis. An alternative method involves trapeziectomy alone (TA). The trapeziectomy with LRTI procedure was developed to theoretically improve biomechanical strength and hand function when compared to TA, which leaves an anatomical void proximal to the first metacarpal. The LRTI procedure takes longer to perform and includes an autologous tendon graft. The goal of this retrospective cohort study was to evaluate the clinical outcomes of trapeziectomy with or without LRTI at a minimum follow-up of 1 year. A total of 43 adult patients who had underwent a total of 58 (TA=36, LRTI=22) surgical procedures for CMC arthritis participated in the study. This single surgeon retrospective cohort study sampled patients who underwent CMC arthroplasty with either TA or LRTI techniques between 2008 and 2020 with a minimum time of 1 year post-operatively. The patients were evaluated subjectively (The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire) and objectively (hand/thumb strength, pre/post-operative hand radiographs). Both the TA and LRTI procedures provided good pain relief, motion, strength, and stability without any severe complications. There was no statistically significant difference in hand or thumb strength between the two groups. Radiography showed that compared to the preoperative status, the trapezial space decreased similarly between the two groups. There was no difference in size of collapse between TA and LRTI post-operatively. The TA procedure had similar outcomes to LRTI and has the advantages of shorter surgical time, less incision length, and lower surgical complexity. TA provided equivalent trapezial space to LRTI after the operation. Future study should investigate these two procedures in a head-to-head comparison rather than longitudinally where both surgeon experience and time since procedure at follow-up may have impacted results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 6 - 6
10 Feb 2023
Lawless A Ebert J Edwards P Aujla R Finsterwald M Dalgleish S Malik S Raymond R Giwnewer U Simpson A Grant M Leys T D'Alessandro P
Full Access

Hamstring grafts have been associated with reduced strength, donor site pain and muscle strains following Anterior Cruciate Ligament Reconstruction (ACLR). Traditional graft fixation methods required both semitendinosus and gracilis tendons to achieve a graft of sufficient length and diameter, but newer techniques allow for shorter, broad single tendon grafts. This study seeks to compare the outcomes between Single Tendon (ST) and Dual Tendon (DT) ACLR, given there is no prospective randomised controlled trial (RCT) in the literature comparing outcomes between these options. In this ongoing RCT: (ANZ Clinical Trials Registry ACTRN126200000927921) patients were recruited and randomised into either ST or DT groups. All anaesthetic and surgical techniques were uniform aside from graft technique and tibial fixation. 13 patients were excluded at surgery as their ST graft did not achieve a minimum 8mm diameter. 70 patients (34 ST, 36DT) have been assessed at 6 months, using PROMS including IKDC2000, Lysholm and Modified Cincinnati Knee, visual analog scale for pain frequency (VAS-F) and severity (VAS-S), dedicated donor site morbidity score, KT-1000 assessment, and isokinetic strength. Graft diameters were significantly lesser in the ST group compared to the DT group (8.44mm/9.11mm mean difference [MD],-0.67mm; P<0.001). There was a significant and moderate effect in lower donor site morbidity in the ST group compared to the DT group (effect size [ES], 0.649; P = .01). No differences between groups were observed for knee laxity in the ACLR limb (P=0.362) or any of the patient-reported outcome measures (P>0.05). Between-group differences were observed for hamstrings strength LSI favouring the ST group, though these were small-to-moderate and non-significant (ES, 0.351; P = .147). ST (versus DT) harvest results in significantly less donor site morbidity and this is the first prospective RCT to determine this. There were no differences between ST and DT hamstring ACLR were observed in PROMs, knee laxity and hamstring strength. Younger female patients tend to have inadequate single tendon size to produce a graft of sufficient diameter, and alternative techniques should be considered. Further endpoints include radiological analysis, longer term donor site morbidity, revision rates and return to sport and will continue to be presented in the future


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 5 - 5
1 Dec 2022
Li T Beaudry E Westover L Chan R
Full Access

The Adams-Berger reconstruction is an effective technique for treating distal radioulnar joint (DRUJ) instability. Graft preparation techniques vary amongst surgeons with insufficient evidence to support one technique over another. Our study evaluated the biomechanical properties of four graft preparation techniques. Extensor tendons were harvested from fresh frozen porcine trotters obtained from a local butcher shop and prepared in one of three configurations (n=5 per group): tendon only; tendon prepared with non-locking, running suture (2-0 FiberLoop, Arthrex, Naples, FL) spaced at 6 mm intervals; and tendon prepared with suture spaced at 12 mm intervals. A fourth configuration of suture alone was also tested. Tendons were allocated in a manner to ensure comparable average diameters amongst groups. Biomechanical testing occurred using custom jigs simulating radial and ulnar tunnels attached to a Bose Electroforce 3510 mechanical testing machine (TA Instruments). After being woven through the jigs, all tendons were sutured end-to-end with 2-0 PROLENE suture (Ethicon). Tendons then underwent a staircase cyclic loading protocol (5-25 Newtons [N] at 1 hertz [Hz] for 1000 cycles, then 5-50 N at 1 Hz for 1000 cycles, then 5-75 N at 1 Hz for 1000 cycles) until graft failure; if samples did not fail during the protocol, they were then loaded to failure. Samples were visually inspected for mode of failure after the protocol. A one-way analysis of variance was used to compare average tendon diameter; post-hac Tuhey tests were used to compare elongation and elongation rate. Survival to cyclic loading was analyzed using Kaplan-Meier survival curves with log rank. Statistical significance was set at a = 0.05. The average tendon diameter of each group was not statistically different [4.17 mm (tendon only), 4.33 mm (FiberLoop spaced 6 mm), and 4.30 mm (FiberLoop spaced 12 mm)]. The average survival of tendon augmented with FiberLoop was significantly higher than tendon only, and all groups had significantly improved survival compared to suture only. There was no difference in survival between FiberLoop spaced 6 mm and 12 mm. Elongation was significantly lower with suture compared to tendon augmented with FiberLoop spaced 6 mm. Elongation rate was significantly lower with suture compared to all groups. Modes of failure included rupture of the tendon, suture, or both at the simulated bone and suture and/or tendon interface, and elongation of the entire construct without rupture. In this biomechanical study, augmentation of porcine tendons with FiberLoop suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol, as suture material was significantly stiffer than any of the tendon graft configurations


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 23 - 23
1 Jan 2022
Mohan R Thomas T Kwaees T Pydisetty R
Full Access

Abstract. Background. The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R). Graft augmentation with suture tape (internal brace) are techniques purported to reduce the risk of rupture and hasten recovery. Our aim was to assess the short-term outcome of ACL-R using fibre tape augmented and non-augmented hamstring tendon grafts. Methods. This was a retrospective comparative study looking at augmented and non-augmented ACL-R. All procedures were performed by a single surgeon in a single centre using the same technique. The Knee injury and Osteoarthritis Outcome Score [KOOS] was used to assess patient-reported outcomes. Results. There were 72 patients in the augmented and 132 patients in the control group. Confounding factors were comparable in both groups. The mean graft diameter in the augmented group was 8.81mm versus 8.01mm in the non-augmented. Six strand graft was achievable in 71% of the augmented group compared to 62.5% in the non-augmented group. Two graft failures reported in the non-augmented group and none in the augmented group. The average 14-month postoperative KOOS in the augmented group was 90.5 compared to an average 30-month score of 82.5 in the non-augmented group, which is statistically significant. Conclusion. Augmented ACL-R demonstrate statistically significant better patient-reported outcomes compared to the nonaugmented group. Graft failure rates may also be lower in augmented ACL-R


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 20 - 20
1 Nov 2019
Chandratreya A Abdul W Guro R Jawad Z Kotwal R
Full Access

Anatomic all-inside ACL reconstruction using TransLateral technique is a relatively new technique that reduces surgical invasion and pain leading to early recovery. We evaluated clinical outcomes of patients undergoing primary anatomic all-inside ACL reconstruction using TransLateral technique. Retrospective case-series evaluating patients undergoing surgery from June 2013 – December 2017. Patients were followed up clinically and using PROMS including EQ-5D, KOOS, IKDC and Tegner scores. Paired two-tailed student t-tests were used to assess clinical significance. 138 patients were included (115 males, 23 females). Mean age was 30 years (range 16.0 – 60.2). Graft choice included isolated semitendinosus (n=115) or both semitendinosus and gracilis (n=26). Mean graft length and diameter were 62.1mm and 8.7mm. Sixteen cases (11.3%) returned to theatre; MUA for arthrofibrosis (n=4), infection (n=2), haemarthrosis (n=1) and metalwork failure (n=1). Incidence of graft re-rupture was 5.7% (n=8); 7 cases were in the mid-bundle femoral tunnel placement. 52.5% (n=74) had complete peri-operative PROMS scores. Mean peri-operative EQ-5D VAS scores were 69.8 and 78.2 (p=0.02). Mean peri-operative KOOS scores for all domains demonstrated significant improvements (p<0.001). Mean peri-operative IKDC scores were 46.1 and 72.5 (p<0.05) and peri-operative Tegner activity scores were 3.3 and 5.3 (p<0.001). Anatomic all-inside ACL reconstruction using TransLateral technique demonstrates favourable clinical and biomechanical advantages including independent anatomic femoral tunnel placement, bone preservation and use of single tendon graft. Patients report significant improvements in pain, functional outcome, quality of life and return to sports. Mid-bundle femoral tunnel placement has been abandoned due to higher failure rate


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 9 - 9
1 May 2015
Smith J Lankester B
Full Access

Medial patellofemoral ligament (MPFL) reconstruction is an effective procedure to address patellofemoral instability, however there remains no clear consensus on the optimum technique. Variations in patella tunnel and the use of patella fixation devices are reported in the literature, as are the associated complications of patella fracture and hardware irritation. We present the early results using a two tunnel, Endobutton free technique. 24 MPFL reconstructions (14 female, 10 male) were performed by a single surgeon, using two 3.5mm medial patellar tunnels exiting anteriorly and a looped, extra-synovial hamstring autograft. Femoral fixation was achieved using an non-absorbable interference screw. Mean age was 25.5 years, with a mean follow-up of 21.7 months. Mean Kujala scores were 60.8 preoperatively and 87.9 postoperatively (p<0.0001). No patient experienced further dislocation or patella fracture post-operatively. One patient required interference screw removal. The surgical technique presented has outcomes comparable with the literature. It requires a shorter tendon graft, and removes the need for a patellar fixation device, reducing potential irritation and cost


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 150 - 150
1 Feb 2012
Chauhan R Baiju D Yaqoob M Geutjens G
Full Access

The aim of this study was to evaluate the functional and clinical outcome following medial patello-femoral ligament reconstruction using autogenous hamstring tendon grafts for patellar instability. Over a 4 year period the senior author operated on 35 patients for lateral instability of the patella. The predominant initiating event was a sporting injury. Each patient had either failed conservative management including physiotherapy, or failed surgical management including tibial tuberosity transfer. Post-operatively, all patients were allowed full flexion and extension. Sporting activity was restricted until 4-6 months post-operatively. Patients were evaluated clinically and functionally. The Fulkerson score was utilised pre- and post-operatively. The minimum follow-up was 6 months, the mean follow-up was 20 months. There were 18 males and 17 females. The mean age was 24.6 years. The mean pre-operative Fulkerson score was 59.3 (range 6-100). The mean post-operative Fulkerson score was 83.6 (range 25-100), the mean improvement was 24.3. 24 patients returned to sporting activities. The main complications were one patient with a patella fracture that was stabilised with internal fixation, one patient requiring exploration and reinforcing the ligament which had attenuated. Both patients finally had a good clinical outcome. Our study has shown that symptomatic lateral instability of the patella can be effectively treated with a medial patello-femoral ligament reconstruction and result in overall good clinical and functional outcome. We would recommend this technique


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVII | Pages 33 - 33
1 May 2012
Nadeem S Al-Ajami A Harrington P
Full Access

The management of scapho-lunate (SL) instability remains controversial. Since 2001, the senior author has used a modified Brunelli tenodesis to achieve soft tissue stabilization in patients presenting with dynamic or static SL instability. From 2001 to 2009, 13 patients were prospectively studied. All patients complained of painful clicking in the wrist, inability to use the wrist for loading activities, and all had a positive scaphoid shift test (Kirk Watson). Wrist arthroscopy was performed to confirm the diagnosis and to confirm the absence of degenerative change in all cases. Data collection pre-operatively included, range of motion, grip strength, DASH score and pain score. All patients had wrist immobilisation in a forearm cast for six weeks post operatively. Physiotherapy commenced at that stage and clinical assessment was performed at 3 months, six months and 12 months post surgery. Patients were discharged from follow-up after 12 months. A significant improvement in grip strength and DASH score was documented at the 12 month post operative assessment. The range of wrist flexion was decreased in all patients. The majority returned to their original employment. All patients reported that their wrist instability symptoms were improved. Conclusion. Scapho-lunate ligament reconstruction using a split flexor carpi radialis tendon graft to achieve soft tissue stabilization, provided satisfactory results in patients with chronic SL instability. Improvement in DASH score and grip strength were documented at one year follow-up


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 213 - 213
1 Sep 2012
Ashmore A Beard D Price A Gill H
Full Access

Aims. Interest in soft tissue Radiostereometric Analysis (RSA) is rising. Previous authors have tried, with varying levels of success, to use this technique to analyse the intra-substance portion of anterior cruciate ligament (ACL) graft constructs. These methods were either prone to large amounts of marker migration, deemed unsuitable for in-vivo use or, where alternative markers such as stainless steel sutures were used, lost the inherent accuracy that made RSA an attractive tool in the first place. We describe a modification of tantalum marker balls that allows for a new method of secure fixation to soft tissue in order to accurately analyse stretch, displacement and, potentially, dynamic movement using RSA. Methods. 1.5 mm tantalum tendon markers were predrilled with 0.3 mm holes, allowing them to be sutured directly to soft tissue. Using a previously described ACL graft model, the amount of marker ball migration was then analysed using RSA after cyclical loading between 20 N and 170 N at 25 Hz for 225,000 cycles. Results. None of 40 balls loosened or became detached from the tendon grafts after 225,000 cycles. Mean migration of the tendon attached marker balls was < 0.1 mm. The maximum imprecision in determining the distance between two markers as assessed by intra- and inter-observer variability was 0.082 mm. Analysis of elastic stretch, plastic stretch, stiffness and localisation of stretch within the graft model was possible due to the low migration levels. Conclusions. This method of attachment of marker beads to soft tissue is simple, reliable and mechanically sound. This technique could potentially be used not only for the post-operative assessment of ACL reconstruction, but in all areas where soft tissue RSA is of interest


Bone & Joint Research
Vol. 1, Issue 3 | Pages 36 - 41
1 Mar 2012
Franklin SL Jayadev C Poulsen R Hulley P Price A

Objectives

Surgical marking during tendon surgery is often used for technical and teaching purposes. This study investigates the effect of a gentian violet ink marker pen, a common surgical marker, on the viability of the tissue and cells of tendon.

Methods

In vitro cell and tissue methods were used to test the viability of human hamstring explants and the migrating tenocytes in the presence of the gentian violet ink.