Bone & Joint Research
Vol. 9, Issue 8 | Pages 450 - 456
1 Aug 2020
Zhang Z Cai Y Bai G Zhang C Li W Yang B Zhang W

Aims. This study aimed to evaluate calprotectin in synovial fluid for diagnosing chronic prosthetic joint infection (PJI) . Methods. A total of 63 patients who were suspected of PJI were enrolled. The synovial fluid calprotectin was tested by an enzyme-linked immunosorbent assay (ELISA). Laboratory test data, such as ESR, CRP, synovial fluid white blood cells (SF-WBCs), and synovial fluid polymorphonuclear cells (SF-PMNs), were documented. Chi-squared tests were used to compare the sensitivity and specificity of calprotectin and laboratory tests. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was calculated to determine diagnostic efficacy. Results. The median calprotectin level was 776 μg/ml (interquartile range (IQR) 536.5 to 1132) in the PJI group and 54.5 μg/ml (IQR, 38.75 to 78.25) in the aseptic failure (AF) group (p < 0.05). Using a threshold of 173 ug/ml, the sensitivity was 95.2%, with a 97.6% specificity, and the AUC was 0.993. The sensitivity of calprotectin of the antibiotic-treated PJI group was 100% versus 90.9% of the non-antibiotic-treated PJI group. Although 47.6% (ten cases) of the patients in the PJI group received antibiotics before aspiration, the diagnostic efficacy of calprotectin was not affected. The sensitivity and specificity of ESR, CRP, SF-WBCs, and SF-PMNs ranged from 76.2% to 90.5% and 64.3% to 85.7%, respectively. Conclusion. Calprotectin in synovial fluid has great diagnostic efficacy for PJI diagnosisand outperformed ESR, CRP, SF-WBCs, and SF-PMNs. Cite this article: Bone Joint Res 2020;9(8):450–456


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 311 - 320
1 Mar 2022
Cheok T Smith T Siddiquee S Jennings MP Jayasekera N Jaarsma RL

Aims. The preoperative diagnosis of periprosthetic joint infection (PJI) remains a challenge due to a lack of biomarkers that are both sensitive and specific. We investigated the performance characteristics of polymerase chain reaction (PCR), interleukin-6 (IL6), and calprotectin of synovial fluid in the diagnosis of PJI. Methods. We performed systematic search of PubMed, Embase, The Cochrane Library, Web of Science, and Science Direct from the date of inception of each database through to 31 May 2021. Studies which described the diagnostic accuracy of synovial fluid PCR, IL6, and calprotectin using the Musculoskeletal Infection Society criteria as the reference standard were identified. Results. Overall, 31 studies were identified: 20 described PCR, six described IL6, and five calprotectin. The sensitivity and specificity were 0.78 (95% confidence interval (CI) 0.67 to 0.86) and 0.97 (95% CI 0.94 to 0.99), respectively, for synovial PCR;, 0.86 (95% CI 0.74 to 0.92), and 0.94 (95% CI 0.90 to 0.96), respectively, for synovial IL6; and 0.94 (95% CI 0.82 to 0.98) and 0.93 (95% CI 0.85 to 0.97), respectively, for synovial calprotectin. Likelihood ratio scattergram analyses recommended clinical utility of synovial fluid PCR and IL6 as a confirmatory test only. Synovial calprotectin had utility in the exclusion and confirmation of PJI. Conclusion. Synovial fluid PCR and IL6 had low sensitivity and high specificity in the diagnosis of PJI, and is recommended to be used as confirmatory test. In contrast, synovial fluid calprotectin had both high sensitivity and specificity with utility in both the exclusion and confirmation of PJI. We recommend use of synovial fluid calprotectin studies in the preoperative workup of PJI. Cite this article: Bone Joint J 2022;104-B(3):311–320


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 6 - 6
1 Mar 2021
Mihalic R Zdovc J Brumat P Trebse R
Full Access

Aim. One of the most accurate and inexpensive tests in detection of prosthetic joint infection (PJI) is synovial fluid white blood cell (WBC) count and differential. Since leukocytes produce many different interleukins (IL) in situation of PJI, we hypothesized that ILs could be even more accurate in detection of PJI. The aim of the study was to test, if the synovial fluid IL-6 level is superior to WBC count and differential in detection of PJI. Methods. Unselected patients undergoing total hip or knee revision surgery were prospectively included. In perioperative assessment phase, WBC count, differential and IL-6 levels of synovial fluid were measured. Patients were labelled as positive or negative according to the predefined cut-off values for IL-6 (230pg/ml) and WBC count with differential (1,7 × 10. 9. WBC/ml with ≥65% of granulocytes). During the surgery, at least 4 intraoperative samples for microbiological and one for histopathological analysis were obtained. PJI was defined as presence of sinus tract, inflammation in histopathological samples, and growth of the same microorganism in at least two or more samples of periprosthetic tissue or synovial fluid. Binary diagnostic test was performed to check the diagnostic strength of both methods in detection of PJI. Results. 49 joints of 48 patients (mean age, 71 years; 53% females) undergoing artificial hip (n = 24) or knee (n = 25) revision surgery were included. 11 joints (22%) were infected. Sensitivity of synovial fluid WBC count with differential was 82%, specificity 97%, accuracy 94%, positive and negative predictive values were 90% and 95%, respectively. Sensitivity of IL-6 level was 73%, specificity 95%, accuracy 90%, positive and negative predictive values were 80% and 92%, respectively. There was a strong statistical agreement between both tests (Kappa value=0.749) and consequently there was no significant difference in detection of PJI comparing both tests (P=0.171). Conclusion. Our study revealed that synovial fluid IL-6 level is not superior to synovial fluid WBC count with differential in detecting PJI


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1047 - 1051
1 Sep 2022
Balato G Dall’Anese R Balboni F Ascione T Pezzati P Bartolini G Quercioli M Baldini A

Aims. The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid. Methods. Between October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy. Results. The AUC was 0.99 (95% confidence interval (CI) 0.98 to 1.00). Receiver operating characteristic (ROC) analysis showed that the optimal cut-off value of synovial fluid alpha-defensin was 1.0 μg/l. The sensitivity of alpha-defensin was 100% (95% CI 96 to 100), the specificity was 97% (95% CI 90 to 98), the positive predictive value was 89.2% (95% CI 82 to 94), and negative predictive value was 100% (95% CI 96 to 100). ROC analysis demonstrated an AUC of 0.99 (95% CI 0.98 to 1.0). Conclusion. The present study confirms the utility of alpha-defensin in the synovial fluid in patients with painful TKA to select cases of PJI. Since LC-MS is still a time-consuming technology and is available in highly specialized laboratories, further translational research studies are needed to take this evidence into routine procedures and promote a new diagnostic approach. Cite this article: Bone Joint J 2022;104-B(9):1047–1051


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 85 - 85
1 Nov 2018
Diakakis N
Full Access

The paramount importance of synovial fluid in lubrication and protection of articular joints has long been recognized. Synovial fluid, a dialysate of plasma, forms an interface with both the synovium and cartilage and plays a crucial role in joint lubrication and bearing functions. In an osteoarthritic joint, damage to the articular cartilage causes modifications in the rheological properties of synovial fluid and, reducing the viscoelasticity and increasing the friction between articular surfaces. Viscosupplementation is a treatment for osteoarthritis that uses hyaluronic acid as a (visco)supplement to the diseased joint. The aim of this treatment is to restore the rheological properties of synovial fluid. Osteoarthritis is the most common disease affecting the joints in human population and among the most important causes of pain, disability and economic loss. Therefore, innovative methods are needed to more effectively treat osteoarthritis, directly addressing the disease process. Among various locomotor mechanisms that could serve to illustrate the integrated nature of functional morphology, perhaps none is more complex than the equine locomotor system. Confronting the need for evaluating the current methods to control joint disease, the horse provides an excellent animal model. As it suffers similar clinical manifestations to those seen in human, it may provide tentative biomedical extrapolations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 70 - 70
24 Nov 2023
Roskar S Mihalic R Trebse R
Full Access

Aim. Prosthetic joint infection (PJI) represents the second most frequent complication of total joint arthroplasty (TJA) with up to 20% of low-grade PJI treated as aseptic failure. Sensitive diagnostic criteria have been provided by EBJIS. However, to date there is no single test to reliably diagnose all PJIs. Studies of Mazzucco et al. and Fu et al. suggest that synovial fluid (SF) viscosity could be considered as an important marker for PJI. The primary aim of our study was to determine if SF viscosity is a more reliable diagnostic criterion of PJI than the SF cell count with differential (CCD), and the combined diagnostic value of SF viscosity and CCD. Method. We prospectively analysed the viscosity of SF samples obtained during TJA of hip and knee revisions. We sampled 2.5–5mL of SF for viscosity and CCD. Intraoperatively, 1mL of the sample was analysed for the CCD. The remaining SF was centrifuged for 4min at 7000rpm. The viscosity of the supernatant was determined on Ostwald viscometer as the time required to pass the viscometer at 20°C. During each surgery at least 5 microbiological and multiple histopathological samples were harvested, and explant sonication was performed. The diagnosis was based on EBJIS definition. The viscosity threshold for detecting PJI was set at 65 seconds. Results. Between December 2020 and January 2023, we analysed 65 knee and 47 hip TJA revision procedures. There were 55 septic and 57 aseptic diagnoses. As a diagnostic marker of PJI, SF viscosity achieved 100% sensitivity and 82.5% specificity, with area under the receiver operating characteristic curve (AUC) of 0.832 (95% CI 0.739, 0.925). The specificity and sensitivity of SF CCD were 98.2% and 78.2%, respectively, with AUC of 0.921 (95% CI 0.869, 0.974). Of the 10 cases incorrectly diagnosed as aseptic based on SF viscosity, 2 were acute traumas and 8 metalloses. The SF CCD in all these cases was <0.5. Of the 12 cases incorrectly diagnosed as aseptic based on SF CCD, 6 cases were culture negative, 4 C. acnes and 2 S. epidemidis isolates in microbiology. Taken together, SF viscosity and CCD achieved a combined AUC of 0.953 (95% CI 0.919, 0.987). Conclusions. Our study is the first to report that SF viscosity is more sensitive but slightly less specific for PJI than SF CCD. The study demonstrates diagnostic value of combining SF viscosity with CCD in decision making in TJA revision surgery


Bone & Joint Research
Vol. 12, Issue 2 | Pages 113 - 120
1 Feb 2023
Cai Y Liang J Chen X Zhang G Jing Z Zhang R Lv L Zhang W Dang X

Aims. This study aimed to explore the diagnostic value of synovial fluid neutrophil extracellular traps (SF-NETs) in periprosthetic joint infection (PJI) diagnosis, and compare it with that of microbial culture, serum ESR and CRP, synovial white blood cell (WBC) count, and polymorphonuclear neutrophil percentage (PMN%). Methods. In a single health centre, patients with suspected PJI were enrolled from January 2013 to December 2021. The inclusion criteria were: 1) patients who were suspected to have PJI; 2) patients with complete medical records; and 3) patients from whom sufficient synovial fluid was obtained for microbial culture and NET test. Patients who received revision surgeries due to aseptic failure (AF) were selected as controls. Synovial fluid was collected for microbial culture and SF-WBC, SF-PNM%, and SF-NET detection. The receiver operating characteristic curve (ROC) of synovial NET, WBC, PMN%, and area under the curve (AUC) were obtained; the diagnostic efficacies of these diagnostic indexes were calculated and compared. Results. The levels of SF-NETs in the PJI group were significantly higher than those of the AF group. The AUC of SF-NET was 0.971 (95% confidence interval (CI) 0.903 to 0.996), the sensitivity was 93.48% (95% CI 82.10% to 98.63%), the specificity was 96.43% (95% CI 81.65% to 99.91%), the accuracy was 94.60% (95% CI 86.73% to 98.50%), the positive predictive value was 97.73%, and the negative predictive value was 90%. Further analysis showed that SF-NET could improve the diagnosis of culture-negative PJI, patients with PJI who received antibiotic treatment preoperatively, and fungal PJI. Conclusion. SF-NET is a novel and ideal synovial fluid biomarker for PJI diagnosis, which could improve PJI diagnosis greatly. Cite this article: Bone Joint Res 2023;12(2):113–120


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1119 - 1126
1 Jun 2021
Ivy MI Sharma K Greenwood-Quaintance KE Tande AJ Osmon DR Berbari EF Mandrekar J Beauchamp CP Hanssen AD Abdel MP Lewallen DG Perry K Block DR Snyder MR Patel R

Aims. The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods. Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm. 3. and ≥ 65% for TKA and ≥ 3,000 cells/mm. 3. and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results. Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion. The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 80 - 80
1 Oct 2022
Morovic P Karbysheva S Meller S Kirschbaum S Perka C Conen A Trampuz A
Full Access

Aim. Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA. Method. Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity. Results. A total of 155 patients were included. Using institutional criteria, 21 patients (14%) were diagnosed with SA and 134 (86%) patients with aseptic arthropathy, out of which 43 (27%) had osteoarthrosis, 80 (52%) had rheumatic arthropathy and 11 (7%) reactive arthritis. The optimal cut-off of synovial fluid D-lactate to differentiate SA from aseptic cases was 0,035 mmol/l. Synovial fluid D-lactate had a sensitivity 90% (95% CI: 70–99%) and specificity 87% (95% CI: 80–92%) compared to leukocyte count with sensitivity 81% (95% CI: 60–95%) and specificity 83% (95% CI: 76–90%). Culture was positive in only 17 (80%) out of 21 patients with SA. Conclusions. The synovial fluid D-lactate showed high sensitivity and specificity for diagnosis of SA which was higher than the current gold standard of diagnosis (culture and leukocyte count). The high sensitivity makes this biomarker useful as a point-of-care screening test for SA


Bone & Joint Research
Vol. 12, Issue 9 | Pages 559 - 570
14 Sep 2023
Wang Y Li G Ji B Xu B Zhang X Maimaitiyiming A Cao L

Aims. To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA). Methods. The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test. Results. For PJI prediction, the results of serological and synovial fluid indexes were different between the RA-PJI and OA-PJI groups. The optimal cutoff value of CRP for diagnosing RA-PJI was 12.5 mg/l, ESR was 39 mm/hour, synovial fluid WBC was 3,654/μl, and PMN% was 65.9%; and those of OA-PJI were 8.2 mg/l, 31 mm/hour, 2,673/μl, and 62.0%, respectively. In the RA-PJI group, the specificity (94.4%), positive predictive value (97.1%), and AUC (0.916) of synovial fluid WBC were higher than those of the other indexes. The optimal cutoff values of synovial fluid WBC and PMN% for diagnosing RA-PJI after THA were significantly higher than those of TKA. The specificity and positive predictive value of the combined index were 100%. Conclusion. Serum inflammatory and synovial fluid indexes can be used for diagnosing RA-PJI, for which synovial fluid WBC is the best detection index. Combining multiple detection indexes can provide a reference basis for the early and accurate diagnosis of RA-PJI. Cite this article: Bone Joint Res 2023;12(9):559–570


Bone & Joint Open
Vol. 1, Issue 12 | Pages 737 - 742
1 Dec 2020
Mihalič R Zdovc J Brumat P Trebše R

Aims. Synovial fluid white blood cell (WBC) count and percentage of polymorphonuclear cells (%PMN) are elevated at periprosthetic joint infection (PJI). Leucocytes produce different interleukins (IL), including IL-6, so we hypothesized that synovial fluid IL-6 could be a more accurate predictor of PJI than synovial fluid WBC count and %PMN. The main aim of our study was to compare the predictive performance of all three diagnostic tests in the detection of PJI. Methods. Patients undergoing total hip or knee revision surgery were included. In the perioperative assessment phase, synovial fluid WBC count, %PMN, and IL-6 concentration were measured. Patients were labeled as positive or negative according to the predefined cut-off values for IL-6 and WBC count with %PMN. Intraoperative samples for microbiological and histopathological analysis were obtained. PJI was defined as the presence of sinus tract, inflammation in histopathological samples, and growth of the same microorganism in a minimum of two or more samples out of at least four taken. Results. In total, 49 joints in 48 patients (mean age 68 years (SD 10; 26 females (54%), 25 knees (51%)) were included. Of these 11 joints (22%) were infected. The synovial fluid WBC count and %PMN predicted PJI with sensitivity, specificity, accuracy, PPV, and NPV of 82%, 97%, 94%, 90%, and 95%, respectively. Synovial fluid IL-6 predicted PJI with sensitivity, specificity, accuracy, PPV, and NPV of 73%, 95%, 90%, 80%, and 92%, respectively. A comparison of predictive performance indicated a strong agreement between tests. Conclusions. Synovial fluid IL-6 is not superior to synovial fluid WBC count and %PMN in detecting PJI. Level of Evidence: Therapeutic Level II. Cite this article: Bone Jt Open 2020;1-12:737–742


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 8 - 8
1 Oct 2022
Busch A Jäger M Giebel B Wegner A Bielefeld C Tertel T
Full Access

Aim. Periprosthetic joint infections (PJI) are severe complications after total joint arthroplasty (TJA). Up to now, a gold standard in the diagnostics of PJI is missing. Small extracellular vesicles (sEVs) are secreted by all types of cells and play a key role in immune response in presence of infection (1). In this prospective study, the diagnostic accuracy of sEVs in the synovial fluid to detect PJI of knee, hip and shoulder joints was investigated. We hypothesized increased surface markers of sEVs in PJI compared to aseptic complications (e.g. implant loosening, stress shielding related pain). Method. Synovial fluid from 48 patients with painful arthroplasty was examined. The distinction between aseptic and infectious cases was made on the basis of the 2018 Definition of Periprosthetic Hip and Knee Infection (2). 35 (72,9%) probands assigned to aseptic and 13 patients (27,1%) to PJI group. Immuno-fluorescence flow cytometry served to document the concentrations of CD9, CD63, CD66b, CD82 and HLA-DR on sEVs. Results. The concentration of CD9 surface marker on sEVs in synovial fluid was significantly lower (p=0.002) in PJI group than in aseptic group. In contrast, the levels of CD82 on sEVs in synovial fluid was significantly higher (p<0.0001) in the PJI group than in aseptic group. The concentrations of CD63, CD66b and HLA-DR on sEVs in synovial fluid did not differ significantly between the two cohorts (CD63: p=0.372; CD66b: p=0.634; HLA-DR: p=0.558). Conclusions. Overall, the significance of sEVs in the diagnostics of PJI is not well enough understood and the subject of current research and scientific discussion. Our data suggest, that CD82 and CD9 on sEVs in synovial fluid are promising biomarkers to differentiate between PJI and aseptic complications


Bone & Joint Research
Vol. 9, Issue 11 | Pages 789 - 797
2 Nov 2020
Seco-Calvo J Sánchez-Herráez S Casis L Valdivia A Perez-Urzelai I Gil J Echevarría E

Aims. To analyze the potential role of synovial fluid peptidase activity as a measure of disease burden and predictive biomarker of progression in knee osteoarthritis (KOA). Methods. A cross-sectional study of 39 patients (women 71.8%, men 28.2%; mean age of 72.03 years (SD 1.15) with advanced KOA (Ahlbäck grade ≥ 3 and clinical indications for arthrocentesis) recruited through the (Orthopaedic Department at the Complejo Asistencial Universitario de León, Spain (CAULE)), measuring synovial fluid levels of puromycin-sensitive aminopeptidase (PSA), neutral aminopeptidase (NAP), aminopeptidase B (APB), prolyl endopeptidase (PEP), aspartate aminopeptidase (ASP), glutamyl aminopeptidase (GLU) and pyroglutamyl aminopeptidase (PGAP). Results. Synovial fluid peptidase activity varied significantly as a function of clinical signs, with differences in levels of PEP (p = 0.020), ASP (p < 0.001), and PGAP (p = 0. 003) associated with knee locking, PEP (p = 0.006), ASP (p = 0.001), GLU (p = 0.037), and PGAP (p = 0.000) with knee failure, and PEP (p = 0.006), ASP (p = 0.001), GLU (p = 0.037), and PGAP (p < 0.001) with knee effusion. Further, patients with the greatest functional impairment had significantly higher levels of APB (p = 0.005), PEP (p = 0.005), ASP (p = 0.006), GLU (p = 0.020), and PGAP (p < 0.001) activity, though not of NAP or PSA, indicating local alterations in the renin-angiotensin system. A binary logistic regression model showed that PSA was protective (p = 0.005; Exp (B) 0.949), whereas PEP (p = 0.005) and GLU were risk factors (p = 0.012). Conclusion. These results suggest synovial fluid peptidase activity could play a role as a measure of disease burden and predictive biomarker of progression in KOA. Cite this article: Bone Joint Res 2020;9(11):789–797


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 36 - 36
1 Dec 2021
Roskar S Mihalic R Trebse R
Full Access

Aim. Prosthetic joint infection (PJI) presents the second most common complication of total joint arthroplasty (TJA). Accumulating evidence suggests that up to 20% of aseptic failures are low-grade PJI. However, there is still no single test to reliably diagnose all PJI. In his thesis, Mazzucco emphasized the viscosity differences between normal, osteoarthritic, and rheumatic synovial fluid. Similarly, a recent study by Fu et al. reported significantly lower viscosity in patients with PJI compared to the aseptic failure cohort. The primary aim of our study was to determine whether synovial fluid viscosity is a more reliable diagnostic criterion for PJI compared to the synovial fluid cell count with differential and serum C-reactive protein (CRP) levels. Method. We prospectively analyzed the viscosity of synovial fluid samples obtained during TJA of hip and knee joint revision procedures. We sampled 2.5–5 mL of synovial fluid for viscosity measurement. The samples were centrifuged (4 min at 7000 rpm) and the resulting supernatant was immediately transferred into the Ostwald viscometer. Viscosity was derived from the time required for a given volume of synovial fluid to pass the viscometer at 20 °C. The synovial fluid samples were also analysed for their cell count with differential and serum CRP was measured. The definite diagnosis of PJI was established on basis of EBJIS criteria. For the viscosity, the threshold for detecting PJI was set at 65 seconds. Results. Between December 2020 and March 2021, we analyzed 12 knee and 11 hip TJA revision samples. These included 14 septic and 9 aseptic synovial fluid samples. The average viscometer time in the PJI group was 31s (range 20–48s) compared to 247s (range 68–616s) in the group of aseptic revision procedures. The specificity and sensitivity of our viscosity measurements were 100%. The sensitivity and specificity of cell count was 100% and 85.7%, for the synovial fluid differential they were 100% and 85.7%, and for the CRP they were 88.9% and 71.4%, respectively. Conclusions. Our study is the first to report a significant difference in synovial fluid viscosity between the PJI and the aseptic cohort. It points towards the diagnostic superiority of viscosity measurements over conventional synovial fluid cell count, synovial fluid differential, and serum CRP levels. Albeit currently limited by small sample size, the study remains ongoing


Bone & Joint Research
Vol. 13, Issue 6 | Pages 261 - 271
1 Jun 2024
Udomsinprasert W Mookkhan N Tabtimnark T Aramruang T Ungsudechachai T Saengsiwaritt W Jittikoon J Chaikledkaew U Honsawek S

Aims. This study aimed to determine the expression and clinical significance of a cartilage protein, cartilage oligomeric matrix protein (COMP), in knee osteoarthritis (OA) patients. Methods. A total of 270 knee OA patients and 93 healthy controls were recruited. COMP messenger RNA (mRNA) and protein levels in serum, synovial fluid, synovial tissue, and fibroblast-like synoviocytes (FLSs) of knee OA patients were determined using enzyme-linked immunosorbent assay, real-time polymerase chain reaction, and immunohistochemistry. Results. COMP protein levels were significantly elevated in serum and synovial fluid of knee OA patients, especially those in the advanced stages of the disease. Serum COMP was significantly correlated with radiological severity as well as measures of body composition, physical performance, knee pain, and disability. Receiver operating characteristic curve analysis unveiled a diagnostic value of serum COMP as a biomarker of knee OA (41.64 ng/ml, area under the curve (AUC) = 1.00), with a sensitivity of 99.6% and a specificity of 100.0%. Further analysis uncovered that COMP mRNA expression was markedly upregulated in the inflamed synovium of knee OA, consistent with immunohistochemical staining revealing localization of COMP protein in the lining and sub-lining layers of knee OA inflamed synovium. Most notably, relative COMP mRNA expression in knee OA synovium was positively associated with its protein levels in serum and synovial fluid of knee OA patients. In human knee OA FLSs activated with tumour necrosis factor-alpha, COMP mRNA expression was considerably up-regulated in a time-dependent manner. Conclusion. All results indicate that COMP might serve as a supportive diagnostic marker for knee OA in conjunction with the standard diagnostic methods. Cite this article: Bone Joint Res 2024;13(6):261–271


Bone & Joint Research
Vol. 9, Issue 7 | Pages 440 - 449
1 Jul 2020
Huang Z Li W Lee G Fang X Xing L Yang B Lin J Zhang W

Aims. The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients. Methods. A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospectively. Ten patients with primary arthroplasties were included as negative controls. Synovial fluid was collected for mNGS analysis. Optimal thresholds were determined to distinguish pathogens from background microbes. Synovial fluid, tissue, and sonicate fluid were obtained for culture. Results. A total of 49 PJI and 21 noninfection patients were finally included. Of the 39 culture-positive PJI cases, mNGS results were positive in 37 patients (94.9%), and were consistent with culture results at the genus level in 32 patients (86.5%) and at the species level in 27 patients (73.0%). Metagenomic next-generation sequencing additionally identified 15 pathogens from five culture-positive and all ten culture-negative PJI cases, and even one pathogen from one noninfection patient, while yielding no positive findings in any primary arthroplasty. However, seven pathogens identified by culture were missed by mNGS. The sensitivity of mNGS for diagnosing PJI was 95.9%, which was significantly higher than that of comprehensive culture (79.6%; p = 0.014). The specificity is similar between mNGS and comprehensive culture (95.2% and 95.2%, respectively; p = 1.0). Conclusion. Metagenomic next-generation sequencing can effectively identify pathogens from synovial fluid of PJI patients, and demonstrates high accuracy in diagnosing PJI. Cite this article: Bone Joint Res 2020;9(7):440–449


Bone & Joint Research
Vol. 9, Issue 9 | Pages 623 - 632
5 Sep 2020
Jayadev C Hulley P Swales C Snelling S Collins G Taylor P Price A

Aims. The lack of disease-modifying treatments for osteoarthritis (OA) is linked to a shortage of suitable biomarkers. This study combines multi-molecule synovial fluid analysis with machine learning to produce an accurate diagnostic biomarker model for end-stage knee OA (esOA). Methods. Synovial fluid (SF) from patients with esOA, non-OA knee injury, and inflammatory knee arthritis were analyzed for 35 potential markers using immunoassays. Partial least square discriminant analysis (PLS-DA) was used to derive a biomarker model for cohort classification. The ability of the biomarker model to diagnose esOA was validated by identical wide-spectrum SF analysis of a test cohort of ten patients with esOA. Results. PLS-DA produced a streamlined biomarker model with excellent sensitivity (95%), specificity (98.4%), and reliability (97.4%). The eight-biomarker model produced a fingerprint for esOA comprising type IIA procollagen N-terminal propeptide (PIIANP), tissue inhibitor of metalloproteinase (TIMP)-1, a disintegrin and metalloproteinase with thrombospondin motifs 4 (ADAMTS-4), monocyte chemoattractant protein (MCP)-1, interferon-γ-inducible protein-10 (IP-10), and transforming growth factor (TGF)-β3. Receiver operating characteristic (ROC) analysis demonstrated excellent discriminatory accuracy: area under the curve (AUC) being 0.970 for esOA, 0.957 for knee injury, and 1 for inflammatory arthritis. All ten validation test patients were classified correctly as esOA (accuracy 100%; reliability 100%) by the biomarker model. Conclusion. SF analysis coupled with machine learning produced a partially validated biomarker model with cohort-specific fingerprints that accurately and reliably discriminated esOA from knee injury and inflammatory arthritis with almost 100% efficacy. The presented findings and approach represent a new biomarker concept and potential diagnostic tool to stage disease in therapy trials and monitor the efficacy of such interventions. Cite this article: Bone Joint Res 2020;9(9):623–632


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 46 - 55
1 Jan 2021
Grzelecki D Walczak P Szostek M Grajek A Rak S Kowalczewski J

Aims. Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Methods. Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed. Results. Patients with PJI had higher CLP concentrations than those undergoing aseptic revision in blood (median PJI 2.14 mg/l (interquartile range (IQR) 1.37 to 3.56) vs AR-TJR 0.66 mg/l (IQR 0.3 to 0.83); p < 0.001) and synovial fluid samples (median PJI 20.46 mg/l (IQR 14.3 to 22.36) vs AR-TJR 0.7 mg/l (IQR 0.41 to 0.95); p < 0.001). With a cut-off value of 1.0 mg/l, blood CLP showed a sensitivity, specificity, positive predictive value, and negative predictive value of 93.3%, 87.5%, 89.4%, and 92.1%, respectively. For synovial fluid with a cut-off value of 1.5 mg/l, these were 95.6%, 95%, 95.5%, and 95%, respectively. Conclusion. This small study suggests that synovial and blood CLP are useful markers in chronic PJI diagnosis with similar or higher sensitivity and specificity than routinely used markers such as CRP, ESR, IL-6, and LE. CLP was not useful to differentiate patients with PJI from those with rheumatoid arthritis. Cite this article: Bone Joint J 2021;103-B(1):46–55


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 463 - 469
1 Apr 2020
Qin L Hu N Li X Chen Y Wang J Huang W

Aims. Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure. Methods. A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker. Results. Serum CD64 index showed no significant difference between the two groups (p = 0.091). Synovial fluid CD64 index and PMN% discriminated good differentiation between groups of PJI and aseptic failure with AUC of 0.946 (95% confidence interval (CI) 0.842 to 0.990) and 0.938 (95% CI 0.832 to 0.987) separately. The optimal threshold value of synovial CD64 index for the diagnosis of PJI was 0.85, with a sensitivity of 92.00%, a specificity of 96.00%, and diagnostic odds ratio (DOR) of 227.11. Conclusion. The present study demonstrates that CD64 index in synovial fluid could be a promising laboratory marker for screening PJI. The cut-off values of 0.85 for synovial CD64 index has the potential to distinguish aseptic failure from PJI. Cite this article: Bone Joint J 2020;102-B(4):463–469


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 32 - 32
1 Dec 2021
Mihalic R Zdovc J Brumat P Trebse R
Full Access

Aim. The cut-off values for synovial fluid leukocyte count and neutrophils differential (%PMN) for differentiating aseptic from septic failure in total knee arthroplasties were already defined in the past. Our goal was to determine the cut-off values for synovial fluid leukocyte count and %PMN in failed total hip arthroplasties (THA). Method. Patients undergoing revision THA were prospectively included. In perioperative assessment phase, synovial fluid leukocyte count and %PMN were determined. During the surgery, at least 4 intraoperative samples for microbiological and one for histopathological analysis were obtained. Infection was defined as presence of sinus tract, inflammation in histopathological samples, and ≥2 tissue and/or synovial fluid samples growing the same microorganism. Exclusion criteria were systemic inflammatory diseases, revision surgery performed less than 3 months from index surgery and insufficient tissue sampling. Receiver operating characteristic (ROC) curves were constructed to assess the diagnostic performance and Youden's J statistic was computed to identify optimal cut-off values. Results. During the study period (between June 2006 and June 2011) 227 revision THAs were performed by the senior author. 31 patients were excluded. 196 patients (mean age, 69 years; 68% females) with THA failure were included. Aseptic failure was diagnosed in 150 patients (76,5%) and THA infection was diagnosed in 46 patients (23,5%). Synovial fluid leukocyte counts were significantly higher in the infected group (median, 5.50×10. 6. leukocytes/ml range, 0.05 to 143.9×10. 6. leukocytes/mL) than in the aseptic group (median, 0.23×10. 6. cells/ml; range, 0 to 21.3×10. 6. leukocytes/ml, P<0,0001). The %PMN was also significantly higher in the infected group (median, 83%; range, 6% to 97%) than in the aseptic group (median, 27,5%; range, 0% to 94%, P<0,0001). A synovial fluid leukocyte count of > 1.54×10. 6. leukocytes/ml, had a sensitivity of 63%, specificity of 95%, positive and negative predictive values of 78% and 89%, respectively. A synovial fluid %PMN of > 64%, had a sensitivity of 65%, specificity of 93%, positive and negative predictive values of 73% and 90%, respectively. Conclusion. The synovial fluid leukocyte count of > 1.54×10. 6. leukocytes/ml and %PMN of > 64% are useful and reliable tests for excluding THA infection, having a negative predictive value of around 90%. This tests and calculated cut-off values are highly recommended in the diagnostic process of failed THAs