Aims. This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. Methods. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis. Results. This biomechanical study predicts that headless screw fixation is a better option if fragment thickness is over 15 mm in terms of the comparable peak failure load to
Suture anchor have been used in surgical procedure of tendon or ligament repair. Recently, there has been developed an all suture anchor (soft anchor) which can be used even when the insertion area is narrow. But, the stability of soft anchors due to narrow zone has not been elucidated. This purpose of this study was to investigate stability of soft anchors with respect to their fixation intervals. Polyurethane foams with two different bone densities (10 pcf; 0.16g / cm³, 20 pcf; 0.32g / cm³) were used. All suture anchors and conventional suture anchors were fixed at 10mm, 5mm, and 2.5mm intervals. The failure load was measured using a mechanical testing machine. The average load to failure of conventional suture anchor
We compared time-dependent changes in the biomechanical properties of single-and double-row repair of a simulated acute tear of the rotator cuff in rabbits to determine the effect of the fixation techniques on the healing process. A tear of the supraspinatus tendon was created in 80 rabbits which were separated into two equal groups. A single-row repair with two suture anchors was conducted in group 1 and a double-row repair with four suture anchors in group 2. A total of ten intact contralateral shoulder joints was used as a control group. Biomechanical testing was performed immediately post-operatively and at four and eight weeks, and histological analysis at four and eight weeks. The mean load to failure in group 2 animals was greater than in group 1, but both groups remained lower than the control group at all intervals. Histological analysis showed similar healing properties at four and eight weeks in both groups, but a significantly larger number of healed tendon-bone interfaces were identified in group 2 than in group 1 at eight weeks (p <
0.012). The ultimate load to failure increased with the number of suture anchors used immediately post-operatively, and at four and eight weeks. The increased load to failure at eight weeks seemed to be related to the increase in the surface area of healed tendon-to-bone in the double-row repair group.
Suture anchor have been used in surgical procedure of tendon or ligament repair. Recently, there has been developed an all suture anchor (soft anchor) which can be used even when the insertion area is narrow. But, the stability of soft anchors due to narrow zone has not been elucidated. This purpose of this study was to investigate stability of soft anchors with respect to their fixation intervals. Polyurethane foams with two different bone densities (10 pcf; 0.16g / cm³, 20 pcf; 0.32g / cm) were used. All suture anchors and conventional suture anchors were fixed at 10mm, 5mm, and 2.5mm intervals. The failure load was measured using a mechanical testing machine.Introduction
Methods
Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or
Restoring of anatomic footprint may improve the healing and mechanical strength of repaired tendons. A double row of suture anchors increases the tendon-bone contact area, reconstituting a more anatomic configuration of the rotator cuff footprint. We aimed to investigate if there were differences in clinical and imaging outcome between single row and double row
Recurrence represents the leading complication of arthroscopic anterior shoulder stabilization. Even with modern
Extensive literature exists relating to the management of shoulder instability, with a more recent focus on glenoid and humeral bone loss. However, the optimal timing for surgery following a dislocation remains unclear. There is concern that recurrent dislocations may worsen subsequent surgical outcomes, with some advocating stabilization after the first dislocation. The aim of this study was to determine if the recurrence of instability following arthroscopic stabilization in patients without significant glenoid bone loss was influenced by the number of dislocations prior to surgery. A systematic review and meta-analysis was performed using the PubMed, EMBASE, Orthosearch, and Cochrane databases with the following search terms: ((shoulder or glenohumeral) and (dislocation or subluxation) and arthroscopic and (Bankart or stabilisation or stabilization) and (redislocation or re-dislocation or recurrence or instability)). Methodology followed the PRISMA guidelines. Data and outcomes were synthesized by two independent reviewers, and papers were assessed for bias and quality.Aims
Methods
Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available. Cite this article:
Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered. Cite this article:
Chronic medial collateral ligament (MCL) instability is an unusual clinical problem. Due to the unsatisfactory results of advancement procedures or reconstruction using autologous techniques we have devised a new technique using a non-irradiated tendo achilles allograft construct. Three patients are presented who had symptomatic MCL insufficiency. The laxity was demonstrated clinically (all grade 3) and radiologically using valgus stress views. The tendo achilles was fashioned into a triangular composite graft consisting of a bone plug (30 x 10 mm) and the tendon. The bone plug was attached to the femur at the anatomical insertion of the MCL using an interference screw and the tendon on the tibia using a multiple
Introduction. This study was performed prospectively and randomly to compare clinical outcomes of modified-Brostrom procedure using single and double suture anchor for chronic lateral ankle instability. Material & Methods. Forty patients were followed up for more than 2 years after modified-Brostrom procedure for chronic lateral ankle instability. Twenty modified-Brostrom procedures with single suture anchor and 20 procedures with double suture anchor randomly assigned were performed by one surgeon. The mean age was 30.6 years, and the mean follow-up period was 2.6 years. The clinical evaluation was performed according to the Karlsson scale and Sefton grading system. The measurement of talar tilt angle and anterior talar translation was performed through anterior and varus stress radiographs. Results. At the last follow-up, the Karlsson scale had improved significantly from preoperative average 45.4 points to 90.5 points in single suture anchor group, from 46.2 points to 91.3 points in double suture anchor group. There were 8 excellent, 10 good, and 2 fair results according to the Sefton grading system in single anchor group, and 9 excellent, 8 good, 3 fair results in double anchor group. Therefore, 18 cases (90%) in single anchor group and 17 cases (85%) in double anchor group achieved satisfactory results. Talar tilt angle had improved significantly from preoperative average 15.7° to 6.1° in single anchor group, from 16.8° to 4.2° in double anchor group. There was significant difference in postoperative talar tilt angle between single and double anchor group. Conclusion. Significant differences in clinical and functional outcomes were not found between single and double
The December 2023 Trauma Roundup360 looks at: Distal femoral arthroplasty: medical risks under the spotlight; Quads repair: tunnels or anchors?; Complex trade-offs in treating severe tibial fractures: limb salvage versus primary amputation; Middle-sized posterior malleolus fractures – to fix?; Bone transport through induced membrane: a randomized controlled trial; Displaced geriatric femoral neck fractures; Risk factors for reoperation to promote union in 1,111 distal femur fractures; New versus old – reliability of the OTA/AO classification for trochanteric hip fractures; Risk factors for fracture-related infection after ankle fracture surgery.
The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated.Aims
Methods
We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Allen suture technique improved the ultimate tensile strength to 359 N for two stitches. Finally, we studied the mechanical properties of several methods of anchorage to bone using typically osteoporotic specimens. Single and even double transosseous sutures and
Rotator cuff tendons are typically reattached to the proximal humerus using either transosseous sutures or suture anchors. Their primary mode of failure is at the tendon bone interface 1. Surgical adhesives are used to bond cartilage, tendons and bone, and to close wounds. In an attempt to increase the tendon-bone interface we investigated the addition of a novel adhesive secreted from a species of Australian frog (Notaden bennetti) 2 to different methods of rotator cuff repair. Forty two fresh frozen sheep infraspinatus tendons were repaired using 3 different techniques: transosseous sutures; two Mitek RC Quickanchors with 1 suture per anchor and two Opus Magnum anchors with 1 suture per anchor all using a mattress stitch configuration. In each group 7 shoulders were repaired with the addition of a small amount of frog glue to the infraspinatus footprint while 7 were used as control with no adhesive. Mechanical testing was performed using a mechanical tensile testing machine. The strongest construct in the control groups was the Mitek suture anchors (mean 86±5 N) followed by the Opus suture anchor (69±6N) and transosseous repair (50±6N). This proved significant (p<
0.05) between both metallic anchors and the transosseous repair.{BR}The addition of frog glue resulted in a significant increase in load to failure and total energy required until failure in all repair techniques (p<
0.01). There was a 2 fold increase in load to failure of both the Opus Magnum (143±8N) and Mitek RC Fastin (165N±20 N) anchors while the transosseous repair (86± 8 N) had a 1.7 fold increase in its load to failure. This data suggests that:.
Purpose: To present the technique and the results of simultaneous arthroscopic reconstruction of Bankart and SLAP lesions in patients with anterior shoulder instability. Method: We performed shoulder arthroscopy in 95 patients aged 16–38 years (mean age:24,8) suffering anterior shoulder instability. Preoperative evaluation included clinical assessment, x-rays, MRI-arthrogram and examination under anaesthesia in comparison to the healthy shoulder. SLAP lesion was fixed using metallic suture anchors (FASTAK 2,4mm x 11,7 mm-Arthrex).The anchor was inserted in a 45° direction relative to the glenoid level. Bankart lesion was reconstructed using 2–3 bioabsorbable suture anchors (Panalok-Mitek J&
J).The arthroscope was inserted through standard posterior, anterosuperior and anteroinferior portals while a posterolateral portal (portal of Whilrnington) was created for SLAP lesion repair. Patients’ average follow-up was 22 months (range, 18–30 months) and the results were evaluated using the ASES score. Results: SLAP lesion was found in 13 patients: 6 pat.-type II (46%), 3 pat.-type I (23%), 2 pat.-type IV (15%), 1pat.-type III (7,6%) and 1 pat with a complex lesion. Of these patients 10 had also co-existed Bankart lesion. In 2 patients Hill-Sachs lesion was found while degenerative rotator cuff changes existed in 3 patients. While performing clinical evaluation anterior instability signs and symptoms were apparent with the patients complaining also for discomfort and crepitus during overhead activities. MRI preoperative sensitivity for SLAP lesion diagnosis was 59% while specificity and Positive predictive value were 90% and 76% respectively. Shoulder function and the overall ASES score improved from 44 pre-op. to 96 post-op. Conclusion: Combined Bankart and SLAP lesions are uncommon in non-throwing patients with anterior instability. Arthroscopic
To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.Aims
Methods
Many biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots. A total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded.Aims
Methods