Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 124 - 124
1 Nov 2021
Mariscal G Camarena JN Galvañ T Barrios C Fernández P
Full Access

Introduction and Objective. The treatment of severe deformities often requiring aggressive techniques such as vertebral resection and osteotomies with high comorbidity. To mitigate this risk, several methods have been used to achieve a partial reduction of stiff curves. The objective of this study was to evaluate and quantify the effectiveness of the Perioperative Halo-Gravity Traction (HGT) in the Treatment of Severe Spinal Deformity in Children. Materials and Methods. A historical cohort of consecutive childs with severe spinal deformity who underwent to a perioperative HGT as a part of the treatment protocol. Minimum follow-up of 2 years. Demographic, clinical and radiological data, including time duration of perioperative HGT and Cobb angle in the coronal and sagittal plane. The radiological variables were measured before the placement of the halo, after placement of the halo, at the end of the period of traction, after surgery and in the final follow-up. Results. Seventeen males (57%) and twenty females (43%) were included in the final analysis. The mean age was 6.5 years (SD 4.8). The most frequent etiology for the spinal deformity was syndromic (13 patients). The average preoperative Cobb angle was 88º (range, 12–135). HGT was used in 17 cases prior to a primary surgery and in 20 cases prior to a revision surgery. After the HGT, an average correction of 34% of the deformity was achieved (p <0.05). After the surgery this correction improved. At 2-year follow-up there was a correction loss of 20% (p <0.05). There were 3 complications (8.1%): 2 pin infections and cervical subluxation. Conclusions. The application of HGT in cases of severe rigid deformity is useful allowing a correction of the preoperative deformity of 34%, facilitating surgery. Preoperative HGT seems to be a safe and effective intervention in pediatric patients with high degree deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 300 - 304
1 Mar 2002
Nötzli HP Siebenrock KA Hempfing A Ramseier LE Ganz R

We used laser Doppler flowmetry (LDF) with a high energy (20 mW) laser to measure perfusion of the femoral head intraoperatively in 32 hips. The surgical procedure was joint debridement requiring dislocation or subluxation of the hip. The laser probe was placed within the anterosuperior quadrant of the femoral head. Blood flow was monitored in specific positions of the hip before and after dislocation or subluxation. With the femoral head reduced, external rotation, both in extension and flexion, caused a reduction of blood flow. During subluxation or dislocation, it was impaired when the posterosuperior femoral neck was allowed to rest on the posterior acetabular rim. A pulsatile signal returned when the hip was reduced, or was taken out of extreme positions when dislocated. After the final reduction, the signal amplitudes were first slightly lower (12%) compared with the initial value but tended to be restored to the initial levels within 30 minutes. Most of the changes in the signal can be explained by compromise of the extraosseous branches of the medial femoral circumflex artery and are reversible. Our study shows that LDF provides proof for the clinical observation that perfusion of the femoral head is maintained after dislocation if specific surgical precautions are followed


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 711 - 719
1 Jul 1998
Sugano N Noble PC Kamaric E Salama JK Ochi T Tullos HS

We studied the morphometry of 35 femora from 31 female patients with developmental dysplasia of the hip (DDH) and another 15 from 15 age- and sex-matched control patients using CT and three-dimensional computer reconstruction models. According to the classification of Crowe et al 15 of the dysplastic hips were graded as class I (less than 50% subluxation), ten as class II/III (50% to 100% subluxation) and ten as class IV (more than 100% subluxation). The femora with DDH had 10 to 14° more anteversion than the control group independent of the degree of subluxation of the hip. In even the most mildly dysplastic joints, the femur had a smaller and more anteverted canal than the normal control. With increased subluxation, additional abnormalities were observed in the size and position of the femoral head. Femora from dislocated joints had a short, anteverted neck associated with a smaller, narrower, and straighter canal than femora of classes I and II/III or the normal control group. We suggest that when total hip replacement is performed in the patient with DDH, the femoral prosthesis should be chosen on the basis of the severity of the subluxation and the degree of anteversion of each individual femur


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1075 - 1081
1 Sep 2002
Bull AMJ Earnshaw PH Smith A Katchburian MV Hassan ANA Amis AA

Our objectives were to establish the envelope of passive movement and to demonstrate the kinematic behaviour of the knee during standard clinical tests before and after reconstruction of the anterior cruciate ligament (ACL). An electromagnetic device was used to measure movement of the joint during surgery. Reconstruction of the ACL significantly reduced the overall envelope of tibial rotation (10° to 90° flexion), moved this envelope into external rotation from 0° to 20° flexion, and reduced the anterior position of the tibial plateau (5° to 30° flexion) (p < 0.05 for all). During the pivot-shift test in early flexion there was progressive anterior tibial subluxation with internal rotation. These subluxations reversed suddenly around a mean position of 36 ± 9° of flexion of the knee and consisted of an external tibial rotation of 13 ± 8° combined with a posterior tibial translation of 12 ± 8 mm. This abnormal movement was abolished after reconstruction of the ACL


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1073 - 1078
1 Nov 1998
Tucker SK Taylor BA

In normal, physiological circumstances there is ample room in the spinal canal to accommodate the spinal cord. Our study aimed to identify the degree of compromise of the spinal canal which could be anticipated in various atlantoaxial pathological states. We examined paired atlas and axis vertebrae using high-definition radiography and simultaneous photography in both normal and simulated pathological orientations in order to measure the resultant dimension of the spinal canal and its percentage occlusion. At the extreme of physiological axial rotation (47°) the spinal canal is reduced to 61% of its cross-sectional area in neutral rotation. The spinal cord is thus safe from compromise. Atlantoaxial subluxation of up to 9 mm reduces the area of the spinal canal, in neutral rotation, to 60% with no cord compromise. Any rotation is, however, likely to cause cord compression. The mechanism of fixation in atlantoaxial rotatory subluxation could be explained by bony interlocking of the facet joint, reproducible in dry bones


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 19 - 19
1 Apr 2017
Corrado P Alan P Michael S
Full Access

Background. As the number of ceramic THR bearings used worldwide is increasing, the number of implants that experience off-normal working conditions, e.g. edge loading, third bodies in the joint, soft tissues laxity, dislocation/subluxation of the joint, increases too. Under all such conditions the bearing surfaces can be damaged, leading eventually to a limitation of the expected performances of the implant. Methods. We characterised the damage resistance of different bearing surfaces (alumina matrix composite BIOLOXdelta, alpha-alumina BIOLOXforte, zirconia 3Y-TZP, oxidized zirconium alloy Zr-2.5Nb, CoCr-alloy) by scratch tests performed following the European standard EN 1071–3:2005. Also the scratch hardness of same materials has been assessed. Results. The Lc1 value (i.e., the load for the onset of a scratch) measured for BIOLOXdelta is about fivefold the one measured for the oxidized zirconium alloy (OXZr) surface and about tenfold the Lc1 measured for the CoCr alloy. The height of ridges along the scratch edges due to plastic flow in the composite ceramic BIOLOXdelta are only 21% in height than in CoCr, and only a small fraction (0.04%) of the height of ridges measured on OXZr surfaces. The scratch hardness of the metal samples tested (CoCr, OXZr) results one order of magnitude lower than the ones of ceramics. This behavior is not influenced by of the presence of the coating on OXZr surface. Conclusions. The transformation toughened ceramics tested (BIOLOXdelta, 3Y-TZP) are the materials that exhibit the higher resistance to scratching. Ridges at scratch edges are lower in ceramics than in coated or uncoated metals. The result show the superior scratch resistance behavior of toughened ceramics for THR wear couples with respect to coated or bare alloys. Level of Evidence. Level 1


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1019 - 1023
1 Jul 2005
Shimogaki K Yasunaga Y Ochi M

Acetabular dysplasia was produced in 24 immature white rabbits. A rotational acetabular osteotomy was then carried out and radiological and histological studies of the articular cartilage were made. In the hips which did not undergo osteotomy, radiographs at 26 weeks showed that residual subluxation remained and arthritic changes such as narrowing of the joint space or dislocation were still seen. However, in the operated group there was a remarkable increase in cover, but arthritic changes were not observed. After 24 weeks, the Mankin grading score in the operated group was significantly lower than that in the non-operated group. The latter hips showed an irregular surface of the cartilage, exfoliation and proliferation of synovial tissue. In those undergoing osteotomy, primary cloning of chondrocytes or hypercellularity was seen and at 24 weeks after operation and metaplasia of the cartilage in the fibrous tissue was observed in the boundary between the medial area of the acetabulum and the acetabular fossa


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2017
Lamontagne M Kowalski E Catelli D Beaulé P
Full Access

Dual mobility (DM) bearing implants reduce the incidence of dislocation following total hip arthroplasty (THA) and as such they are used for the treatment of hip instability in both primary and revision cases. The aim of this study was to compare lower limb muscle activity of patients who underwent a total hip arthroplasty (THA) with a dual mobility (DM) or a common cup (CC) bearing compared to healthy controls (CON) during a sit to stand task. A total of 21 patients (12 DM, 9 CC) and 12 CON were recruited from the local Hospital. The patients who volunteered for the study were randomly assigned to either a DM or a CC cementless THA after receiving informed consent. All surgeries were performed by the same surgeon using the direct anterior approach. Participants underwent electromyography (EMG) and motion analysis while completing a sit-to-stand task. Portable wireless surface EMG probes were placed on the vastus lateralis, rectus femoris, biceps femoris, semitendinosus (ST), gluteus medius and tensor fasciae latae muscles of the affected limb in the surgical groups and the dominant limb in the CON group. Motion capture was used to record lower limb kinematics and kinetics. Muscle strength was recorded using a hand-held dynamometer during maximal voluntary isometric contraction (MVIC) testing. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalized to the MVIC and time cycle for the sit to stand task. Using iEMG, quadriceps-hamstrings muscle co-activation index was calculated for the task. Nonparametric Kruskal Wallace ANOVA tests and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred. The DM group had greater iEMG of the ST muscle compared to the CC (p=0.045) and the CON (p=0.015) groups. The CC group had lower iEMG for hamstring muscles compared to the DM (p=0.041) group. The DM group showed lower quadriceps-hamstrings co-activation index compared to the CON group and it approached significance (p=0.054). The CC group had greater anterior pelvis tilt compared to both DM (p=0.043) and the CON (p=0.047) groups. The DM also had larger knee varus angles and less knee internal rotation compared to both groups, however this never reached significance. No significant differences in muscle strength existed between the groups. Higher ST muscle activity in the DM group is explained by the reduction in internal rotation at the knee joint as the ST muscle was more active to resist the varus forces during the sit-to-stand task. Reduced quadriceps activity in the CC group is explained by increased pelvic anterior tilt as this would shorten the moment arm and muscle length in the quadriceps, ultimately reducing quadriceps muscle activity. The reduced co-activation between quadriceps and hamstrings activity in the DM group compared to the CC and CON groups is related to better hip function and stability. Combining lower co-activation and larger range of motion for the DM group without impingement, this implant seems to offer better prevention against THA subluxation and less wear of the implant


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 17 - 17
1 Mar 2013
Kulshreshtha R Gibson C Jariwala A Wigderowitz C
Full Access

Various authors have linked hypermobility at the trapeziometacarpal joint to future development of arthritis. When examining hypermobility, the anterior oblique ligament (AOL) and ulnar collateral ligament (UCL) are the two most important supporting structures. Literature suggests that reconstructive techniques to correct the hypermobility can prevent subsequent development of osteoarthritis. Eaton and Littler proposed a surgical technique to reconstruct the ligamentous support of this joint in 1973. This cadaveric biomechanical study aimed to evaluate the resultant effect on the mobility of the thumb metacarpal following this reconstructive technique. Seventeen cadaveric hands were prepared and strategically placed on a jig. Movements at the trapeziometacarpal joint were created artificially. Static digital photographs were taken with intact AOL and UCL at trapeziometacarpal joint (controls), for later comparison with those after sectioning of these ligaments and following Eaton-Littler reconstructive technique. The photographic records were analyzed using Scion.Image. Statistical analysis was performed using Minitab. A paired T-test was used to establish statistical relevance. Results confirmed that the AOL and UCL had a major role in limiting excessive motion at the trapeziometacarpal joint, principally in extension. Division of these ligaments produced a significant degree of subluxation of the metacarpal at this joint with thumb in neutral position (p-value = 0.013). Reconstruction of the ligamentous support using the Eaton-Littler technique reduced the degree of extension available (p-value = 0.005). This study confirmed the important role of the AOL and UCL in maintaining trapeziometacarpal joint stability, and that the Eaton-Littler reconstructive technique reduces the degree of hyperextension at this joint


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 31 - 31
1 Aug 2013
Hopper G Wells J Leach W Rooney B Walker C Blyth M
Full Access

The Medial Patellofemoral Ligament (MPFL) is the main restraining force against lateral patellar displacement. It is often disrupted following patellar subluxation or dislocation. MPFL reconstruction is frequently performed when conservative management fails and the patient experiences recurrent patellar dislocation. Various MPFL reconstruction procedures have been described in the literature and reported outcomes are encouraging. This study analyses the radiographic outcomes following MPFL reconstruction. From January 2006 to January 2011, 76 consecutive patients (80 knees) with patellar recurrent dislocation underwent medial patellofemoral ligament reconstruction in three large teaching hospitals. Mean follow-up was 31.8 months (range, 13–72). Semitendinosus and gracilis autografts were used for the reconstruction and all procedures were carried out by the senior authors (WL, BR, CW, MB). Plain radiographs (Anteroposterior (AP), Lateral and Skyline) performed preoperatively and postoperatively were used to compare the sulcus angle, congruence angle, lateral patellofemoral angle, trochlear dysplasia (Dejour classification), trochlear boss height and patellar height (Caton-Deschamps ratio). Plain radiographs (Lateral) performed postoperatively were used to evaluate the femoral tunnel placement used for MPFL reconstruction. The sulcus angle improved from 143.2° (122.9–157.7) to 139.3° (115.7–154.6) and the congruence angle improved from 26.7° (−17.5–82.6) to 0.26° (−35.3–7.8). The lateral patellofemoral angle was 7.99° (3.2–19.2) preoperatively and 9.02° (3.2–18.2) postoperatively. The Caton-Deschamps ratio was 1.2 (1.0–1.5) preoperatively and 1.0 (0.8–1.1) postoperatively. Using the Dejour classification of trochlear dysplasia, all preoperative radiographs were considered to be grade C or D and all postoperative radiographs were considered to be grade A or B. Trochlear boss height was 5.9mm (1.8–11.6) preoperatively and 4.7mm (1.6–6.9) postoperatively. 59% of the femoral tunnels were considered to be in a good position on postoperative radiographs. This study displayed a significant improvement in postoperative radiographic parameters, demonstrating the importance of anatomic restoration when performing MPFL reconstruction


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 65 - 65
1 May 2012
Hart A Lloyd G Sabah S Sampson B Underwood R Cann P Henckel J Cobb PJ Lewis A Porter M Muirhead-Allwood S Skinner J
Full Access

SUMMARY. We report a prospective study of clinical data collected pre, intra and post operation to remove both cup and head components of 118 failed, current generation metal on metal (MOM) hips. Whilst component position was important, the majority were unexplained failures and of these the majority (63%) had cup inclination angles of less than 55 degrees. Poor biocompatibility of the wear debris may explain many of the failures. BACKGROUND. Morlock et al reported a retrospective analysis of 267 MOM hips but only 34 head and cup couples (ie most were femoral neck fractures) and without data necessary to define cause of failure. The commonest cause of failure in the National Joint Registry (NJR) is unexplained. METHODS. We categorised the cause of failure, as defined by the NJR, of all MOM hips received over an 18 month period that had a full set of pre, intra and post op data. A group of 40 patients with unilateral well functioning MOM hips was used for comparison. RESULTS. In the retrieval group, the median age was 61 years (25 to 87) and there were 80 females and 38 males. The median time between primary and revision operation was 35 months (4 to 121). Femoral head size was <50mm in 89 and >=50mm in 29. The causes of failure were: unexplained in 75; aseptic loosening (acetabular) in 12; aseptic loosening (femoral) in 7; dislocation/subluxation in 1; infection in 11; periprosthetic femoral fracture in 2; malalignment in 6; size mismatch in 3; other in 1. 47 (63%) of unexplained failures had cup inclination angles of less than 55 degrees. The unexplained failures had increased blood metal ions (p <0.0001) and cup inclination angle (p <0.005) but a decreased femoral head size (p <0.0001) when compared to well functioning MOM hip patients. CONCLUSION. The commonest cause of failed MOM hips was unexplained. Comparison to well functioning hips revealed that the mechanism may involve high blood metal ions but high cup inclination angle was not found in the majority of cases. Further biological and mechanical investigation into the underlying mechanism of failure is required


Objectives

Adult mice lacking the transcription factor NFAT1 exhibit osteoarthritis (OA). The precise molecular mechanism for NFAT1 deficiency-induced osteoarthritic cartilage degradation remains to be clarified. This study aimed to investigate if NFAT1 protects articular cartilage (AC) against OA by directly regulating the transcription of specific catabolic and anabolic genes in articular chondrocytes.

Methods

Through a combined approach of gene expression analysis and web-based searching of NFAT1 binding sequences, 25 candidate target genes that displayed aberrant expression in Nfat1-/- AC at the initiation stage of OA, and possessed at least four NFAT1 binding sites in the promoter of each gene, were selected and tested for NFAT1 transcriptional activities by chromatin immunoprecipitation (ChIP) and promoter luciferase reporter assays using chondrocytes isolated from the AC of three- to four-month-old wild-type mice or Nfat1-/- mice with early OA phenotype.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 1 - 10
1 Jan 2016
Burghardt RD Manzotti A Bhave A Paley D Herzenberg JE

Objectives

The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method.

Methods

In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 141 - 144
1 Jan 2015
Hughes AW Clark D Carlino W Gosling O Spencer RF

Reported rates of dislocation in hip hemiarthroplasty (HA) for the treatment of intra-capsular fractures of the hip, range between 1% and 10%. HA is frequently performed through a direct lateral surgical approach. The aim of this study is to determine the contribution of the anterior capsule to the stability of a cemented HA through a direct lateral approach.

A total of five whole-body cadavers were thawed at room temperature, providing ten hip joints for investigation. A Thompson HA was cemented in place via a direct lateral approach. The cadavers were then positioned supine, both knee joints were disarticulated and a digital torque wrench was attached to the femur using a circular frame with three half pins. The wrench applied an external rotation force with the hip in extension to allow the hip to dislocate anteriorly. Each hip was dislocated twice; once with a capsular repair and once without repairing the capsule. Stratified sampling ensured the order in which this was performed was alternated for the paired hips on each cadaver.

Comparing peak torque force in hips with the capsule repaired and peak torque force in hips without repair of the capsule, revealed a significant difference between the ‘capsule repaired’ (mean 22.96 Nm, standard deviation (sd) 4.61) and the ‘capsule not repaired’ group (mean 5.6 Nm, sd 2.81) (p < 0.001). Capsular repair may help reduce the risk of hip dislocation following HA.

Cite this article: Bone Joint J 2015;97-B:141–4.


Bone & Joint Research
Vol. 4, Issue 3 | Pages 29 - 37
1 Mar 2015
Halim T Clarke IC Burgett-Moreno MD Donaldson TK Savisaar C Bowsher JG

Objectives

Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt–chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA).

Methods

Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range 5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments (5 mg) were inserted at ten intervals during the five million cycle (5 Mc) test.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 595 - 601
1 Apr 2010
Kafchitsas K Kokkinakis M Habermann B Rauschmann M

In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation.

After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantly reduced (p < 0.001). Our study indicates that the increase in the intervertebral disc height after disc replacement changes the geometry at the facet joints. This may have clinical relevance.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1460 - 1465
1 Oct 2010
Rauh PB Clancy WG Jasper LE Curl LA Belkoff S Moorman CT

We evaluated two reconstruction techniques for a simulated posterolateral corner injury on ten pairs of cadaver knees. Specimens were mounted at 30° and 90° of knee flexion to record external rotation and varus movement. Instability was created by transversely sectioning the lateral collateral ligament at its midpoint and the popliteus tendon was released at the lateral femoral condyle. The left knee was randomly assigned for reconstruction using either a combined or fibula-based treatment with the right knee receiving the other. After sectioning, laxity increased in all the specimens. Each technique restored external rotatory and varus stability at both flexion angles to levels similar to the intact condition. For the fibula-based reconstruction method, varus laxity at 30° of knee flexion did not differ from the intact state, but was significantly less than after the combined method.

Both the fibula-based and combined posterolateral reconstruction techniques are equally effective in restoring stability following the simulated injury.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 130 - 138
1 Apr 2014
Shapiro F Connolly S Zurakowski D Flynn E Jaramillo D

Objectives

An experimental piglet model induces avascular necrosis (AVN) and deformation of the femoral head but its secondary effects on the developing acetabulum have not been studied. The aim of this study was to assess the development of secondary acetabular deformation following femoral head ischemia.

Methods

Intracapsular circumferential ligation at the base of the femoral neck and sectioning of the ligamentum teres were performed in three week old piglets. MRI was then used for qualitative and quantitative studies of the acetabula in operated and non-operated hips in eight piglets from 48 hours to eight weeks post-surgery. Specimen photographs and histological sections of the acetabula were done at the end of the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 577 - 582
1 Apr 2005
Senavongse W Amis AA

Normal function of the patellofemoral joint is maintained by a complex interaction between soft tissues and articular surfaces. No quantitative data have been found on the relative contributions of these structures to patellar stability. Eight knees were studied using a materials testing machine to displace the patella 10 mm laterally and medially and measure the force required. Patellar stability was tested from 0° to 90° knee flexion with the quadriceps tensed to 175 N. Four conditions were examined: intact, vastus medialis obliquus relaxed, flat lateral condyle, and ruptured medial retinaculae. Abnormal trochlear geometry reduced the lateral stability by 70% at 30° flexion, while relaxation of vastus medialis obliquus caused a 30% reduction. Ruptured medial retinaculae had the largest effect at 0° flexion with 49% reduction. There was no effect on medial stability. There is a complex interaction between these structures, with their contributions to loss of lateral patellar stability varying with knee flexion.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 977 - 982
1 Jul 2009
Terrier A Merlini F Pioletti DP Farron A

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data.

After one year of use, the volumetric wear was 8.4 mm3 for the anatomical prosthesis, but 44.6 mm3 for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.